Hatco HBG Series Скачать руководство пользователя страница 8

INSTALLATION

6

Form No. HBGM-0608

General

Use the following procedures to install the HBG and
HBGB units.

ELECTRIC SHOCK HAZARD: Do not attempt to
repair or replace a damaged power cord. The
cord must be replaced by Hatco, an Authorized
Hatco Service Agent, or a person with similar
qualifications.

FIRE HAZARD: Locate the unit a minimum of 1″
(25 mm) from combustible walls and materials. If
safe distances are not maintained, combustion
or discoloration could occur.

Locate the unit at the proper counter height in
an area that is convenient for use. The location
should be level to prevent the unit or its
contents from falling accidentally and strong
enough to support the weight of the unit and
contents.

Do not lay unit on the side with the control panel
or damage to the unit could occur.

HBG Models

1. Remove unit from box.

2. Remove the information packet.

NOTE: To prevent delay in obtaining warranty

coverage, fill out and mail in the warranty

card to Hatco.

3. Remove tape and protective packaging from all

surfaces of unit.

4. Place the unit in the desired location. Make sure

all the feet on the bottom of the unit are
positioned securely on the countertop.

ELECTRIC

SHOCK

HAZARD:

Unit

is

not

weatherproof. Locate the unit indoors where the
ambient air temperature is a minimum of 70°F
(21°C).

HBGB Models

Do not operate built-in models without the
control box mounted properly as described in
the installation instructions.

CAUTION

WARNING

NOTICE

CAUTION

WARNING

This unit is recommended for use in metallic
countertops. Damage to non-metallic countertop
material caused by heat generated from Hatco
equipment is not covered under the Hatco
warranty. For other surfaces, verify that the material
is suitable for temperatures up to 200°F (93°C).

1. Remove unit from box.

2. Remove information packet.

NOTE: To prevent delay in obtaining warranty

coverage, fill out and mail in the warranty

card to Hatco.

3. Remove tape and protective packaging from all

surfaces of unit.

4. Prepare the countertop opening. Refer to the

“Countertop Cutout” chart on the following page
for

recommended

countertop

cutout

dimensions.

5. Apply a bead of NSF-approved sealant on the

top edge of the countertop cutout and the
underside of the trim mounting ring (see
Figure 7). The sealant must be rated for use at
a minimum temperature of 250°F (121°C).

6. Place the unit into the countertop opening.

7. Remove any excess sealant.

8. Locate the remote control box assembly in an

area that is convenient for operation. If
necessary, remove the end brackets from the
control box, rotate, and reposition them. The
control box will require a hole mounting pattern
of 7-5/8″ x 1-1/4″ (194 mm x 32 mm). See
Figure 8 for mounting distances.

NOTE: The remote control box should be mounted

using screws with a 1/4″ (6 mm) minimum

diameter screw head inserted through the

keyholes located on the mounting brackets.

The remote control box is to be readily

removable, not permanently mounted.

Do not modify wiring or cut thermostat capillary
wire on control box to increase semi-remote
mounting distance. Cutting the thermostat
capillary wire will cause the unit to overheat and
may damage the unit as well as the surrounding
countertop.

9. Once all components are secured, proceed to

the OPERATION section.

NOTE: A 6′ (1829 mm) cord is supplied with this

appliance; any excess cord should be

neatly routed so it does not hang down.

NOTICE

NOTICE

All manuals and user guides at all-guides.com

Содержание HBG Series

Страница 1: ...al please bring it to the attention of your supervisor Keep this manual in a safe location for future reference No opere este equipo al menos que haya le do y comprendido el contenido de este manual C...

Страница 2: ...fety Information 1 Model Designation 2 Model Descriptions 2 All Models 2 HBG Models 2 HBGB Models 2 Specifications 3 Dimensions HBG Models 3 Dimensions HBGB Models 3 Plug Configurations 4 Electrical R...

Страница 3: ...lls and materials If safe distances are not maintained combustion or discoloration could occur This unit has no user serviceable parts and must be serviced by qualified personnel only If service is re...

Страница 4: ...Black Glass shelf is a portable shelf with an attached 6 1829 mm cord and plug The portable unit is available in six models HBG 2418 HBG 3018 HBG 3618 HBG 4818 HBG 6018 and HBG 7218 Figure 2 Model HB...

Страница 5: ...64 mm 1391 mm 324 mm HBG 7218 72 3 8 18 3 8 2 1 2 66 3 4 12 3 4 1838 mm 467 mm 64 mm 1695 mm 324 mm A D E B C Front View Side View Figure 4 Dimensions HBG Model Width Depth Height Model A B C HBGB 241...

Страница 6: ...230 240 CE 1148 1250 5 0 5 2 BS 1363 or AS 3112 54 lbs 25 kg HBG 7218 120 1260 10 5 NEMA 5 15P 64 lbs 29 kg 220 230 CE 1260 1378 5 7 6 0 CEE 7 7 Schuko 64 lbs 29 kg 230 240 CE 1378 1500 6 0 6 3 BS 13...

Страница 7: ...63 or AS 3112 37 lbs 17 kg HBGB 4818 120 850 7 1 NEMA 5 15P 54 lbs 25 kg 220 230 CE 840 918 3 8 4 0 CEE 7 7 Schuko 54 lbs 25 kg 230 240 CE 918 1000 4 0 4 2 BS 1363 or AS 3112 54 lbs 25 kg HBGB 6018 12...

Страница 8: ...is not covered under the Hatco warranty For other surfaces verify that the material is suitable for temperatures up to 200 F 93 C 1 Remove unit from box 2 Remove information packet NOTE To prevent de...

Страница 9: ...76 mm 19 483 mm HBGB 4818 48 3 4 1238 mm 49 1245 mm 18 3 4 476 mm 19 483 mm HBGB 6018 60 3 4 1543 mm 61 1549 mm 18 3 4 476 mm 19 483 mm HBGB 7218 72 3 4 1848 mm 73 1854 mm 18 3 4 476 mm 19 483 mm Trim...

Страница 10: ...s arc to determine approximate mounting distances for semi remote controls Top View Under Counter Surface Recessed Panel Figure 8 Maximum Semi Remote Mounting Distance for HBGB Model Control Box All m...

Страница 11: ...arranty 1 Using an appropriate cleaning wipe or a damp cloth clean the glass surface of the unit Consistent daily cleaning will keep cleanup easy as well as protect and preserve the glass surface of t...

Страница 12: ...E 10 Form No HBGM 0608 Cleaning Burned On Residue To clean burned on residue the use of ceramic glass cleaner may be necessary 1 Allow the unit to cool 2 Spread a few drops of ceramic glass cleaner on...

Страница 13: ...Contact Authorized Service Agent or Hatco for assistance Contact Authorized Service Agent or Hatco for assistance Plug unit into proper power supply Adjust thermostat control to a higher setting Block...

Страница 14: ...crew holes see Figure 10 2 Remove trim cover from control panel assembly 3 Position control panel into opening through the backside 4 Secure control panel to surface using screws not supplied NOTICE W...

Страница 15: ...at lamp bulbs coated halogen light bulbs halogen heat lamp bulbs heated glass shelves glass components Product failure in booster tank fin tube heat exchanger or other water heating equipment caused b...

Страница 16: ...EBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 973 575 9145 Ser...

Отзывы: