OPTIONS
12
Form No. HBGM-0608
Remote Mounted Control Panel
(HBGB Model)
A flush-style remote mounted control panel is
available as a factory-installed option for the HBGB
unit. Install the control panel on-site using the
following procedure.
ELECTRIC
SHOCK
HAZARD:
The
remote
mounted control panel must be mounted on a
vertical wall and installed in the vertical position.
Mounting the control panel in the horizontal
position may result in the collection of liquids
and lead to an electric shock.
The remote mounted control panel should be
installed outside of the heat zone. Locating the
control panel inside the heat zone will cause the
control(s) to overheat, malfunction, and fail. See
Figure 8 for maximum mounting distances.
Do not modify wiring or cut thermostat capillary
wire on control box to increase semi-remote
mounting distance. Cutting the thermostat
capillary wire will cause the unit to overheat and
may damage the unit as well as the surrounding
countertop.
NOTE: A qualified electrician is recommended for
installing the remote mounted control panel.
1. Prepare cutout and pre-drill screw holes (see
Figure 10).
2. Remove trim cover from control panel assembly.
3. Position control panel into opening through the
backside.
4. Secure control panel to surface using screws
(not supplied).
NOTICE
WARNING
5. Plug the control panel into a properly grounded
electrical outlet of the correct voltage, size, and
plug
configuration.
Refer
to
the
SPECIFICATIONS section for details.
6. Reinstall trim cover.
NOTE: Units are equipped with a 36″
(914 mm) flexible conduit connecting the
control panel to the unit.
Power ON/OFF Switch
The remote mounted control panel is equipped with
a power ON/OFF switch. Move the power ON/OFF
switch to the ON position to turn on the unit. The
indicator light in the switch glows when the unit is on
(see Figure 11).
Adjusting the Thermostat Control Panel
Turn the thermostat control clockwise to increase
the temperature setpoint. Turn the thermostat
control
counterclockwise
to
decrease
the
temperature setpoint.
Figure 11. Thermostat Control Panel
HATCO CORP. MILWAUKEE, WI U.S.A.
OFF
ON
1
2
3
4
5
6
7
8
9
10
Thermostat
Control
Power ON/OFF Switch
Figure 10. Remote Mounted Control Panel Installation Dimensions
4-3/4″
(121 mm)
A
D
B
C
Cutout
Screw Hole
Dimension
Dimension
(A)
(C)
5-7/8″
3-7/8″
(149 mm)
(98 mm)
(B)
(D)
6-3/8″
6-3/4″
(162 mm)
(171 mm)
All manuals and user guides at all-guides.com