background image

CONTENTS 

 

Precautions .………………………………………………………………………..................... Page 

2

Specifications ………………………………………………………………………................... Page 

3

Unit Installation ………………………………………………………………………………….. 

1.  Evaporative Cooler ……………………………………………………...................... Page 

3

2.  Wiring …………………………………………………………………………………... 

Page 3

3.  Water connections ……………………………………………………………………. 

Page 4

Operation 

1.  Standard Unit ………………………………………………………………………….. 

Page 4

2.  Unit with automatic Drain Kit …………………………………………….................. 

Page 5

3.  Unit with Automatic Drain Kit and Freeze Protection ………………………………

Page 5

Service and Parts ………………………………………………………….................. 

Pages 6 and 7

Trouble Shooting ………………………………………………………………………………... 

Page 8

 
 
 
 
 
 
 
 
 

 
 
 

PRECAUTIONS 

 

1. 

Read these instructions before installation and operation; save for future reference.  This 
manual contains necessary information for safe operation and maintenance of the unit. 

 

2. 

Shut off

 main power and lock it in the 

off

 position when making repairs or replacements of 

components. 

 

3. Use 

extreme caution

 when making voltage tests with “live” circuits – follow the 

established safety procedures. 

 

4. 

Electrical repairs should be performed by trained, qualified personnel only.  (Failure to 
follow safe electrical procedures can result in series injury – or 

death.

 

5. 

Do not

 attempt to operate unit by jumping, or otherwise bypassing, any circuit. 

 

6. 

Keep evaporator reservoir clean.

  Do not

 allow fine sediments or scale to accumulate in 

reservoir, on filter media, or on other components. 

 

7. 

Do not

 exceed water pressures recommended in this manual. 

 

WARNING 

 

         This  equipment  was  designed  and manufactured with safe  operation  as   
a priority.  However, the very nature of any equipment having water and 
electrical connections presents hazards to personnel which cannot be 
completely safeguarded against. 

- 2 - 

Содержание EC-40

Страница 1: ...on arrival inspect the unit for shipping damage and completeness If any part is missing or damaged notify the carrier immediately Always refer to the unit s serial and model numbers located on the specification plate when making an inquiry regarding maintenance and parts To insure unit integrity use only Factory Authorized Replacement Parts ISEC 1 July 1997 ...

Страница 2: ...ts of components 3 Use extreme caution when making voltage tests with live circuits follow the established safety procedures 4 Electrical repairs should be performed by trained qualified personnel only Failure to follow safe electrical procedures can result in series injury or death 5 Do not attempt to operate unit by jumping or otherwise bypassing any circuit 6 Keep evaporator reservoir clean Do ...

Страница 3: ... 130ºF 165ºF Maximum Air Temperature 300ºF 300ºF pH Range 6 9 6 9 Cabinet Aluminized Steel and Painted Evaporator Reservoir Stainless Steel and Painted INSTALLATION INSTRUCTIONS 1 When installing the evaporative cooler special consideration should be given to the physical positioning of the unit electrical power supply the proper water supply and the structural members to support the cooler at the...

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ... valve until it disappears The exact amount will depend upon the pH and hardness of the water and the intensity of evaporation Clean and flush distribution header on a regular basis Water depositing into Transition and Reservoir Not Draining 1 Reservoir float valve FV improperly adjusted See Installation Instructions note 4 2 Float valve bad not shutting off Replace 3 Check overflow and drain valv...

Отзывы: