1
INSTRUCTIoNS FoR USe
eN
Safety Instructions
To avoid the risk of fire, do not dry clothes or leave
any towels in the infrared cabin.
To prevent burns or electric shocks, do not touch or
use metal tools on the radiators.
The light bulb heats in use. If the bulb needs to be
changed, unplug the cabin and let the bulb cool
down before changing it.
Do not spray water on the radiators. This may result
in electric shock or damage to the radiators.
Do not let young, handicapped or ill people use the
cabin on their own.
Consult your doctor about any health-related
limitations to using the cabin.
Never go to a hot infrared cabin if you have taken
alcohol, strong medicines or narcotics.
Maintenance Instructions
Clean the cabin with a damp cotton towel, dry with
a clean dry towel.
Do not use strong cleaning chemicals on the cabin.
•
•
•
•
•
•
•
•
•
Plug the infrared cabin into a proper wall outlet. Do not
share the outlet with any other appliances. The infrared
cabin should be unplugged when not in use. After 2 hours
of continuous use, switch the cabin off for one hour.
Otherwise the components’ working life may shorten.
A. Switch the infrared cabin on/off.
B. Set the desired temperature.
Press and hold to make the value change faster.
C. Set the desired on-time.
Press and hold to make the value change faster.
The range is 5–0 minutes.
When there is 5 minutes left, the control unit will
sound an alarm.
The cabin will switch off automatically after the
on-time has run out.
D. Switch the light on/off.
e. Adjust air circulation in the cabin.
Change the unit of temperature (°C/°F)
Press and hold simultaneously the buttons ”+” and ”–”,
then press ”Light” to change.
•
•
•
•
•
E
error messages
error message in the
temperature display
Description
Remedy
eP
Temperature sensor failure.
Check the wires to the temperature sensor
and their connections for faulties. Replace
the sensor.
H
Temperature in the infrared cabin
too high.
Switch off the infrared cabin and let it cool
down.
00
(infrared cabin does not heat)
Radiator failure.
Check the functioning of the radiators.
Change any broken radiators.
C
A
B
D