background image

 

 

Installation of Mounting Brackets, Tank, and Drain / Fill Line (continued) 
 

If your baler has a sidewind jack, complete the next steps. If your baler does not have a sidewind jack, skip to 
the tank installation on page 7. 

Locate the jack bracket assembly (001-4704KM) and fasten it to the existing jack mounted on the baler shown 
at point G in figure 7 using two 

1/2” x 4½” bolts, flats, locks, and nuts. Locate the support bracket (001-

4704KG) and fasten it to the top hole on the jack bracket assembly (001-4704KM) shown at point H in figure 8 
using a ½” x 1½” bolt, flat, lock and nut. You may have to cut off the end of the support bracket (001-4704KG) 
at the notch to fit the baler.  
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Locate the support bracket (001-4704KG) and fasten it to the inside of the U-Bracket (001-4704KB) shown at 
point I in Figure 9 below using two 3/8” x 1¼” bolts, flats, locks, and nuts.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

001-4704KG 

001-4704KB 

001-4704KJ 

Figure 9 

001-4704KG 

001-4704KM 

Figure 7 

001-4704KM 

Figure 8 

001-4704KM 

Содержание 438K

Страница 1: ...438K 21 INST Imp Metric 04 21 Installation Owner s Manual Model 438K 25 Gallon Electronic Preservative Applicators Forage Harvester...

Страница 2: ...preservatives for hay Harvest Tec system meets the Directive 2006 42 EC of the European Parliment and the Council of 17 May 2006 and other applicable European Directives including Directive 2004 108 E...

Страница 3: ...Please read this manual carefully to ensure correct steps are followed to attach the applicator to the baler This applicator is designed to apply Harvest Tec buffered acid Use of alternative products...

Страница 4: ...ne 001 4704KS to each the left and right mounting brackets at point A using two 3 8 x 1 1 4 bolts for each stiffener bracket Secure the left and right mounting brackets 001 4704KE and 001 4704KF to th...

Страница 5: ...flats locks and nuts Locate the tank bracket 001 4704KA as shown in figure 5 Fasten 001 4704KA to the tank saddle U Bracket 001 4704KB with four 1 2 x 1 bolts locks flats and nuts at the four corners...

Страница 6: ...ts locks and nuts Locate the support bracket 001 4704KG and fasten it to the top hole on the jack bracket assembly 001 4704KM shown at point H in figure 8 using a x 1 bolt flat lock and nut You may ha...

Страница 7: ...8 x 1 bolts locks flats and nuts Drill a 3 8 hole in the baler tongue and fasten 001 4704KR to the baler tongue using a 3 8 x 1 bolt lock flat and nut Locate the tank 005 4705T as shown in figure 11...

Страница 8: ...sten the drain fill kit with the supplied hardware in the drain fill kit 5 16 self tapping bolts Mount Pump Plate Assembly Use four 3 8 x 1 1 4 bolts locks and flat washers to mount the pump bracket 0...

Страница 9: ...the gauge and to the check valve Secure to baler using the padded jiffy clips provided Use hose clamps on all connections A Drill two 3 8 holes and mount pressure gauge to sheet metal Bend the gauge b...

Страница 10: ...solenoid on all 12v tractors Connect the green lead marked to the hot terminal on the starter Connect the black lead to a good ground Do not reverse the leads Be sure to use a voltmeter to verify that...

Страница 11: ...mical and making a mess if leaks are found When you are comfortable with the operation of the controls you can set the applicator to the amount of chemical you would like it to put on Message Light Th...

Страница 12: ...re Using the chart on the following page cross reference 2 minutes with 1000lbs and you will come up with 14 ton per hour DETERMINE THE RATE OF CHEMICAL The number of pounds of chemical required to be...

Страница 13: ...for the moisture you are applying at This sum will give you the application rate 2 Select the proper set of tips from the application rate chart and install them 3 For the tips you have selected you w...

Страница 14: ...96 336 N A 50 97 116 203 348 N A 55 102 122 214 366 N A 60 107 128 224 384 N A GENERAL CALIBRATION CHART IN GALLONS PER HOUR Use the following chart for all applications that require volume measuremen...

Страница 15: ...rs of use Rebuilding the pump is a simple procedure if the motor is not damaged Order pump rebuilding kit 007 4581 6 If you are using bacterial inoculants flush out system daily after each use 7 Clean...

Страница 16: ...ter bowl assembly 2 Electronic box out of adjustment 2 Refer to box adjustment page 3 Pump worn or dirty 3 Rebuild pump 4 Low supply voltage Pump requires 12v minimum 4 Check voltage at connection wit...

Страница 17: ...ener Bracket V1 001 4704KS 2 12 Tank Fitting 005 9100 2 4 Mounting Bracket LH V2 001 4704KE 1 13 20 Gallon Tank 005 4705T 1 5 Mounting Bracket RH V2 001 4704KF 1 14 Tank Cap 005 9022C 1 6 Jack Bracket...

Страница 18: ...07H 1 6 Hose clamp 003 9003 8 15 Control box 030 0457 1 7 Hose clamp 003 9004 2 16 Power harness 006 4580C 1 8 Male shut off 002 2205G 1 17 Pump harness 006 4583 1 Ref Description Part Qty Ref Descrip...

Страница 19: ...traight fitting 003 A1412 5 Inside Tip Red Set 004 XR11001VS 1 6 Plug 003 F14 1 Green Cap 004 1207A 3 7 Hose clamp 003 9003 5 Outside Tip Green Set 004 6501 SS 2 8 Male quick fitting 004 4710 3 Inside...

Страница 20: ...s warranty does not extend to loss of crop losses caused by delays or any expense prospective profits or for any other reason Harvest Tec Inc shall not be liable for any recovery greater in amount tha...

Отзывы: