General Information

Warranty

BTX warranties this BTX Oocyte Petri Electrode for a period of 90 days from date of 

purchase. At its option, BTX will repair or replace the item if it is found to be defective 

as to workmanship or material. This warranty does not extend to damage resulting from 

misuse, neglect, or abuse, normal wear and tear, 

 

or accident. This warranty extends only to the original customer purchase.
IN NO EVENT SHALL HARVARD APPARATUS BE LIABLE FOR INCIDENTAL OR 

CONSEQUENTIAL DAMAGES. Some states do not allow exclusion or limitation of 

incidental or consequential damages so the above limitation or exclusion may not apply 

to you. THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS 

FOR A PARTICULAR USE, OR OF ANY OTHER NATURE. Some states do not allow this 

limitation on an implied warranty, so the above limitation may not apply to you. If a 

defect arises within the 90 day warranty period, promptly contact: BTX, 84 OCTOBER 

Hill Road, Holliston, MassacHusetts 01746-1388

 using our toll free number 

1-800-272-2775 (outside tHe u.s. call 1-508-893-8999).

 Goods will not be accepted 

for return unless an RMA (Return Materials Authorization) number has been issued by 

our customer service department. The customer is responsible for shipping charges. 

Please allow a reasonable period of time for completion of repairs or replacement and 

return. If the unit is replaced, the replacement unit is covered only for the remainder 

of the original warranty period dating from the purchase of the original device. This 

warranty gives you specific rights, and you may also have other rights which vary from 

state to state.
NOTE: BTX electrodes are not recommended for use with power supplies or cables from 

other manufacturers. Such use is completely at the customer’s own risk as it may result 

in damage, create unsafe conditions and will immediately void the 90 day warranty.
IMPORTANT: Read all instructions, warnings and precautions prior to use.

Technical & Customer Service

BTX® is the ultimate resource for technical information on the use of high voltage 

transfection and general electroporation of molecules and drugs into tissue. We 

constantly track and monitor scientific publications in this area. Our Technical Service 

group extracts and enters pertinent information, such as results and parameters from 

these papers into a Protocol database. This database is available via the BTX website. 

Please visit www.btxonline.com. For technical assistance, additional information or an 

inquiry/request for repair service, contact BTX Technical Support/Customer Service 

Group at:

BTX® A Division of Harvard Bioscience 

84 October Hill Road 

Holliston, Ma 01746-1388 u.s.a.

 

Toll Free: 1-800-272-2775 (U.S. only) 

Phone: 1-508-893-8999

 

Fax: 1-508-429-5732

 

E-mail: [email protected] 

Internet: www.btxonline.com

If outside the United States and Canada: call 1-508-893-8999 or contact your nearest 

BTX Distributor. A complete list of distributors is on our website.

Содержание BTX Oocyte Petri Electrode 45-2059

Страница 1: ...Oocyte Petri Electrode 45 2059 45 2060 15 mm Oocyte Petri Electrode Platinum 1 mm gap electrode only 15 mm Oocyte Petri Electrode Platinum 1 mm gap Kit 45 2059 45 0503 45 0204 User s Manual ...

Страница 2: ...n If the unit is replaced the replacement unit is covered only for the remainder of the original warranty period dating from the purchase of the original device This warranty gives you specific rights and you may also have other rights which vary from state to state Note BTX electrodes are not recommended for use with power supplies or cables from other manufacturers Such use is completely at the ...

Страница 3: ... medium might lead to flashover between the electrodes ARC and or explosive evaporation of the medium Reduce voltage or pulse length to avoid repeating this condition DO NOT OPERATE WITH SUSPECTED FAILURES If you suspect there is damage to the product have it inspected by qualified BTX service personnel DO NOT CONTACT ELECTRODES To avoid fire or shock hazard observe all ratings and markings on the...

Страница 4: ...es can be visualized during electroporation This electrode is particularly useful for the generation of transgenic animals including use with CRISPR Cas 9 constructs to both knock in and knock out targeted genes The Oocyte Petri Electrode may be cleaned with a mild detergent and sterilized with 75 ethanol This electrode requires the use of Mini Micro Grabber Cables 45 0503 and Tweezertrode Adapter...

Страница 5: ...s on the slide Suggested fill volumes are 7 µl for 70 embryos and 10 µl for 100 120 embryos 5 Deliver the electroporation pulse s to the sample 6 Recover sample with wide bore pipette tip During a session of multiple electroporations using the same transfectant excess buffer may be removed with a sterile eye spear in between rounds of electroporation 7 Disconnect from Mini Micro Grabber cables and...

Страница 6: ...20 to 80 Physical Characteristics Item No Electrode Length Electrode Gap Electrode Material 45 2059 15 mm 1 mm Medical Grade Polished Platinum Compatibility Generators BTX Gemini X2 ECM 830 ECM 2001 Please contact BTX Technical Service at any of the numbers listed below in the event of any failure BTX A Division of Harvard Bioscience 84 October Hill Road Holliston MA 01746 1388 U S A Toll Free 1 8...

Отзывы: