In use, the CGA Tailpiece couples to the fill connection on the container being filled. The
Relief Valve vents pressure over 350 psig (24 bar/2413 kPa) that builds up in the fill line
due to trapped liquid. The Dump Valve is used to allow the operator to blow-don the
receiving container during a pump fill, or to relieve residual pressure from expanding liquid
trapped in the line before disconnecting the fill line.
Fill kits are available with different combinations of hose length and fittings for a specific
gas service. The following chart identifies the available transfer hoses and fill tee assem-
blies.
TRANSFER HOSE CHART
Description
Cylinder
End
Part
(Service/Hose Length) Connections(s)
Fittings
Number
Inert (N2,Ar) Service
4 ft. (1.2 m) Stainless Steel
LIQUID or VENT Valve
CGA 295 to 3/8 in. NPT
1700-9C65
6 ft. (1.8 m) Stainless Steel
LIQUID or VENT Valve
CGA 295 to 3/8 in. NPT
1600-9C66
6 ft. (1.8 m) Stainless Steel
USE Valve
CGA 580 to 3/8 in. NPT
GL50-8C51
Oxygen Service
6 ft. (1.8 m) Stainless Steel
LIQUID or VENT Valve
CGA 440 to 3/8 in. NPT
GL50-8C53
6 ft. (1.8 m) Stainless Steel
USE Valve
CGA 540 to 3/8 in. NPT
GL50-8C56
Carbon Dioxide Service
6 ft. (1.8 m) Stainless Steel
LIQUID or USE Valve
CGA 320 to 3/8 in. NPT
HP50-8C51
4 ft. (1.2 m) Stainless Steel
VENT Valve
CGA 295 to 3/8 in. NPT
1700-9C65
6 ft. (1.8 m) Stainless Steel
VENT Valve
CGA 295 to 3/8 in. NPT
1600-9C66
Nitrous Oxide Service
4 ft. (1.2 m) Stainless Steel
VENT Valve
CGA 295 to 3/8 in. NPT
1700-9C65
6 ft. (1.8 m) Stainless Steel
VENT Valve
CGA 295 to 3/8 in. NPT
1600-9C66
Fill Hose Kits