992 8608 001 . THERMISTER ASSEMBLY . . . . . . 1 . .
RT001 #SCREWED TO SINK
992 8957 001 . PWA, 1/4 MOD, HB RF, . . . . . . . . . 1 . .
Table 8-19. PWA, 1/4 MOD, HB RF, - 992 8957 001
HARRIS P/N
DESCRIPTION
QTY/UM
REF. SYMBOLS/EXPLANATIONS
254 0001 000 . WIRE, BUS CU 22AWG . . . . . . . . . .1 . . FT
#L010
296 0310 000 . TUBING TEFLON 20 AWG . . . . . . . .1 . . FT
#L010
358 3288 000 . POWER TAP, PC MOUNT 25AMP . 1 . .
TB001
384 0843 000 . DIODE 1N4154 . . . . . . . . . . . . . . . . 1 . .
CR001
516 0417 000 . CAP 1000PF 10% 200V . . . . . . . . . 6 . .
C025 C026 C027 C028 C033 C043
516 0484 000 . CAP 0.1UF 100V 10% . . . . . . . . . . 2 . .
C029 C030
516 0831 000 . CAP 0.010UF 10% 100V . . . . . . . . 7 . .
C021 C022 C023 C024 C042 C044
C045
516 0890 000 . CAP 470PF 10% 200V . . . . . . . . . . 4 . .
C009 C011 C034 C035
524 0375 000 . CAP 100UF 63V . . . . . . . . . . . . . . . 2 . .
C031 C032
540 0880 000 . RES 47.0 OHM 1/4W 5% . . . . . . . . 1 . .
R012
540 0888 000 . RES 100 OHM 1/4W 5% . . . . . . . . . 1 . .
R013
540 0914 000 . RES 1.2K OHM 1/4W 5% . . . . . . . . 4 . .
R007 R008 R009 R010
548 1102 000 . RES 1.5K OHM 1/4W 1% . . . . . . . . 1 . .
R014
548 1116 000 . RES 2.74K OHM 1/4W 1% . . . . . . . 4 . .
R024 R025 R026 R027
548 1120 000 . RES 2K OHM 1/4W 1% . . . . . . . . . 1 . .
R017
548 1508 000 . RES 715 OHM 1/4W 1% . . . . . . . . . 1 . .
R015
548 2069 000 . RES 49.9K OHM 1/4W 1% . . . . . . . 2 . .
R022 R023
548 2158 000 . RES 1.65K OHM 1/4W 1% . . . . . . . 1 . .
R016
550 0913 000 . POT, 5K OHM . . . . . . . . . . . . . . . . . 4 . .
R018 R019 R020 R021
550 0957 000 . POT 500 OHM 1/2 W 10% . . . . . . . 1 . .
R002
610 1223 000 . HEADER 3 POSITION . . . . . . . . . . 1 . .
J001
839 7900 702 . SCH, HB 1/4 MODULE . . . . . . . . . . 0 . .
843 4999 641 . PWB, TEFLON RF 1/4 MOD HB . . . 1 . .
917 2100 536 . WIRE ASSY, 14 TURN TOROID . . . 1 . .
L009
Table 8-20. DIVIDER, HB, 2-WAY - 992 8557 007
HARRIS P/N
DESCRIPTION
QTY/UM
REF. SYMBOLS/EXPLANATIONS
000 0000 010 . B/M NOTE: . . . . . . . . . . . . . . . . . . . 0 . .
THIS ITEM USED AT HIGHER LEVEL
RES, 100 OHM, 20W, R1 544-1660-000
384 0321 000 . DIODE 5082-2800/1N5711 . . . . . . . 1 . .
CR001
516 0929 000 . CAP 470PF 10% 200V . . . . . . . . . . 1 . .
C001
540 0912 000 . RES 1.0K OHM 1/4W 5% . . . . . . . . 1 . .
R003
548 0049 000 . RES 100 OHM .5W 1% . . . . . . . . . . 1 . .
R002
843 4999 494 . PWB, DIVIDER 2-WAY . . . . . . . . . . 1 . .
Table 8-21. COMBINER, HB 2 X 2 WAY - 992 8558 007
HARRIS P/N
DESCRIPTION
QTY/UM
REF. SYMBOLS/EXPLANATIONS
000 0000 010 . B/M NOTE: . . . . . . . . . . . . . . . . . . . 0 . .
THIS ITEM USED AT HIGHER LEVEL
RES,100 OHM, 250W, R1,R2544-1654-000
843 4999 490 . PWB, HB COMB/DIV 2X2 . . . . . . . . 1 . .
8-16
(888-2365/2377/2378/2400/2402/2450-xxx)
10-15-96
WARNING: Disconnect primary power prior to servicing.
Содержание Platinum Series
Страница 4: ......
Страница 6: ......
Страница 8: ...ii 888 2365 001 02 24 97 WARNING Disconnect primary power prior to servicing ...
Страница 12: ...This page left blank intentionally ...
Страница 22: ...1 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Страница 52: ...3 20 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...
Страница 62: ...4 10 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Страница 63: ...Section IV Theory of Operation 888 2365 001 4 11 WARNING Disconnect primary power prior to servicing ...
Страница 64: ...4 12 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Страница 65: ...Section IV Theory of Operation 888 2365 001 4 13 WARNING Disconnect primary power prior to servicing ...
Страница 66: ...4 14 888 2365 001 WARNING Disconnect primary power prior to servicing ...
Страница 80: ...5 14 888 2365 001 Rev B 1 11 1999 WARNING Disconnect primary power prior to servicing ...
Страница 134: ...8 22 888 2365 2377 2378 2400 2402 2450 xxx 10 15 96 WARNING Disconnect primary power prior to servicing ...
Страница 156: ...B 2 888 2345 001 888 2353 001 888 2354 001 888 2365 001 WARNING Disconnect primary power prior to servicing ...