Power Output
1000W
800W
600W
400W
200W
100W
PA Volts
92.5
84
74
62
46.5
35
PA Amps
12.5
11.3
10
8.4
6.4
4.9
PDM Level
6.4
5.8
5.1
4.3
3.2
2.4
Supply Voltage
242
244
246
248
252
254
Supply Current
4.8
4.1
3.3
2.5
1.6
1.1
RF Drive
7.4
7.4
7.4
7.4
7.4
7.4
VSWR Detector Null
0
0
0
0
0
0
VSWR Detector Null Set
5.3
5.3
5.3
5.3
5.3
5.3
Underdrive Set
6.4
5.8
5.1
4.3
3.2
2.4
Supply Current Set
8.3
8.3
8.3
8.3
8.3
8.3
Supply Voltage Set
297
297
297
297
297
297
Battery
9.8
9.8
9.8
9.8
9.8
9.8
The readings above are typical readings. Refer to the Factory Test Data Sheets supplied for readings actually obtained during factory
tests.
Table 2-7. GATES ONE
Typical Readings at 1340kHz
Power Output
2500W
2000W
1500W
1000W
500W
200W
PA Volts
98.5
90.0
79.0
66.0
50.0
35.0
PA Amps
28.7
26.1
23.0
19.0
14.0
10.0
PDM Level
6.8
6.2
5.5
4.6
3.4
2.4
Supply Voltage
249
250
252
257
260
265
Supply Current
12.0
10.0
8.0
5.0
3.0
2.0
RF Drive
8.9
8.8
8.8
9.0
9.0
9.0
VSWR Detector Null
0
0
0
0
0
0
VSWR Detector Null Set
6.6
6.6
6.6
6.6
6.6
6.6
Underdrive Set
6.7
6.2
5.5
4.5
3.4
2.4
Supply Current Set
23.5
23.5
23.5
23.5
23.5
23.5
Supply Voltage Set
299
299
299
299
299
299
Battery
9.8
9.8
9.8
9.8
9.8
9.8
The readings above are typical readings. Refer to the Factory Test Data Sheets supplied for readings actually obtained during factory
tests.
Table 2-8. GATES TWO
Typical Readings at 800kHz
2-10
888-2314-001
Rev. AC: 2/29/00
WARNING: Disconnect primary power prior to servicing.
Содержание Gates Five 994 9204 002
Страница 4: ......
Страница 6: ...iv 888 2314 001 Rev X WARNING Disconnect primary power prior to servicing...
Страница 8: ...vi 888 2314 001 Rev X WARNING Disconnect primary power prior to servicing...
Страница 28: ...2 12 888 2314 001 Rev AC 2 29 00 WARNING Disconnect primary power prior to servicing...
Страница 40: ...Figure 5 1 PDM Flow Diagram 5 2 888 2314 001 Rev T Jan 1996 WARNING Disconnect primary power prior to servicing...
Страница 42: ...Figure 5 2 PDM Loop 5 4 888 2314 001 Rev T Jan 1996 WARNING Disconnect primary power prior to servicing...
Страница 43: ...Figure 5 3 RF Flow Rev T Jan 1996 888 2314 001 5 5 WARNING Disconnect primary power prior to servicing...
Страница 76: ...C 6 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Страница 82: ...E 4 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Страница 88: ...F 6 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Страница 96: ...H 2 888 2314 001 Rev AA 8 18 1999 WARNING Disconnect primary power prior to servicing...
Страница 104: ...K 2 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Страница 105: ...Figure K 1 Interface Board Rev AE 03 05 2002 888 2314 001 K 3 WARNING Disconnect primary power prior to servicing...
Страница 108: ...L 2 888 2314 001 WARNING Disconnect primary power prior to servicing...