DVSD / DVSE6800
+
Installation and Operation Manual
21
Chapter 3: Operation
Setting Remotely-Controlled Parameters
describes DVSD / DVSE6800
+
parameters that are accessible
remotely. See your CCS control software application manual or online
help for more information on setting and monitoring the following
parameters remotely. Items marked with an asterisk (*) are the default
values.
Table 3-2.
Remotely Controlled Parameters
Name
Range
Description
Loss of Signal
Switch
• 0 = Disable*
• 1 = Enable
Loss of signal (on input 1) switching enable, automatically
switch both output MUXs to select input 2 when input 1
has lost its input signal.
If LOSen is enabled:
• Input 1 is monitored; if Input 1 is lost, all outputs will
be switched to Input 2 (applies to 1×8 Input 1
configuration and dual 1×4 configuration)
• If any of the outputs are already set to Input 2 (e.g., 1×8
Input 2), nothing changes
Ch. 1 / 2 Signal
Present [RO]
• 0 = No
• 1 = Yes
Input 1 / 2 signal is present
Ch. 1 / 2 Output
Select
• 0 = Input 1*
• 1 = Input 2
Ch. 1 / 2 output select; selects which input channel to
output (used to configure the module to operate as either
1×8 or dual 1×4)
Ch. 1 / 2 Loss of Input
Alarm
• 0 = Disabled*
• 1 = Enabled
Enables or disables the Loss of Input alarm for channel 1
or channel 2
DVSE6800
+
Only
Ch. 1 / 2 Loss of Lock
Alarm
• 0 = Disabled*
• 1 = Enabled
Enables or disables the Loss of Lock alarm for channel 1
or channel 2
Ch. 1 / 2 Re-clocking
Mode
• 0 = Auto
• 1 = 19.4
• 2 = 143
• 3 = 177
• 4 = 270
• 5 = 360
• 6 = 540
• 7 = Bypass
Determines reclocking mode