4 – Configuration & Operation
NetXpress LX & CM-30 Installation & Operation Manual
Version 1, September 2010
Harris Corporation
4-83
Intraplex Products
Loopbacks
Local:
Click the
On
option to enable a local loopback. Click the
Off
option to disable the loopback. For
testing purposes, a loopback sends the input channel audio and signaling to its own local output
channel.
Channels 1-4:
Click the
On
option to enable a loopback on the specific channel, or click the
Off
option to disable the loopback. When a remote loopback is active (
On
), the local channel card sends a
loopback command to the far end channel card. The far end card continues to process the incoming
receive side data and sends it to the user as usual but also loops that data to the transmit side of the
module, processes it and returns the data to the originating card.
Refresh:
Click this button to refresh the browser.
Submit:
Click this button to apply the configuration values entered on this page.
Reset:
Click this button to reverse all changes to this page.
Previous Card:
Click this button to view configuration and status pages for the module on the
immediate left of this module.
Next Card:
Click this button to view configuration and status pages for the module on the immediate
right of this module.