FAX 5/10/20/30/40KW
October 28, 2013
6
‐
3
888
‐
2720
‐
001
WARNING:
Disconnect
primary
power
prior
to
servicing.
Copyright
©2013,
Harris
Broadcast
6.2.3
System Interface Control Module LED Indicators
Figure
6
‐
2
shows
the
FAX
transmitter
System
Interface
Control
Module
Status
LEDs.
Following
Figure
6
‐
2
is
an
explanation
of
status
LEDs
based
on
its
illuminated
color
and
troubleshooting
tips
to
resolve
warnings
and
faults
when
they
occur.
Note
Each 10kW power Block contains an System Interface Control Module that is located at the right end of
the Power Supply Modules. This card interfaces with all the main subassemblies in the 10kW Power Block
including the front panel LCD Controller. The System Interface Control Module contains Life-Support
(Backup Mode) circuits to enable transmitter operation if the front panel LCD Controller should ever fail.
The Interface Controller contains user buttons to facilitate most transmitter operational functions. In
20kW/30kW/40kW systems, the main Power Block contains an additional identical Interface Control
Module that is referred to as the Multi Unit System Control Module. It is located directly above the Power
Supply Modules in the Main Power Block Cabinet. The Multi Unit System Controller Module interfaces
with each Power Block Cabinet’s Interface Control Module. Both Interface cards are identical. Onboard
Dipswitches determine the configuration (function) of each card.
The
following
picture
shows
the
front
edge
of
a
System
Interface
Control
Module
illustrating
the
front
panel
LEDs.
There
are
also
2
columns
of
surface
mount
LEDS
down
the
middle.
In
a
FAX20/30/40
the
LED’s
that
are
available
depends
on
if
the
card
is
acting
as
a
Multi
‐
Unit
Interface
or
System
Interface.
If
acting
as
System
Interface
in
each
power
block,
faults
that
are
Transmitter
faults
will
not
appear
on
this
card.
Only
the
faults
that
pertain
to
that
power
block
will
appear.
However,
all
faults
will
show
up
in
the
fault
log.
SYSTEM
LED
is
Red
Transmitter
has
a
serious
fault
and
Transmitter
may
be
OFF
or
Software
Control
has
been
disabled
either
by
user
or
a
failed
control
board.
An
Interlock
open,
Cooling
fault
or
RF
Mute
has
occurred.
Check
other
Status
LED’s
and
fault
log
for
further
information.
MUTE
LED
is
Green
Transmitter
is
ON
and
unmuted.
Mute
LED
will
be
green
when
transmitter
is
OFF.
MUTE
LED
is
Red
Transmitter
is
ON
and
Muted.
Check
Equipment
Interlock
J1
‐
9
of
USER
REMOTE
connector
on
rear
of
power
block
1.
Check
MUTE
line
J1
‐
7
of
USER
REMOTE
connector
on
rear
of
power
block
1.
Transmitter
also
will
flash
MUTE
LED
red
when
switching
to
backup
exciter
or
IPA,
it
should
go
back
green
once
switching
is
complete.
Restrike
command
will
briefly
turn
MUTE
LED
red.
Symptom
Cause
and
Solution
Содержание Flexiva FAX 5KW
Страница 2: ......
Страница 8: ......
Страница 10: ...WARNING Disconnect primary power prior to servicing...
Страница 167: ......