User Manual
Operation and Management
Page 4-46
(Rev. 4.1/ SW v1.60/ December 2006)
4.2.4.
Filtering
Filtering
is a licensing required feature that allow the user to define a method
for PID Filtering on PVR 6000 ASI and IP output ports.
The following summarizes the
Filtering
procedures, using both Front Panel and
Web-Based Management interfaces:
F
ILTERING THROUGH THE
F
RONT
P
ANEL
In order to use filtering mode thru the front panel perform the following steps:
•
Configure ASI or/and IP outputs to filtering mode (see section
4.2.3.2
:
Configuration
Î
Stream
Î
Output
Î
ASI Output Source
Î
After Filtering
Configuration
Î
Stream
Î
Output
Î
IP Output Source
Î
After Filtering
•
Access the general screen by navigating to:
Root
Æ
Configuration
Æ
Stream
Æ
Filtering
Filtering
1-2-2-4
1
General
2
Service
3
PID
•
Set the following parameters at the
General
sub menu: strategy, mode, Bit-
rate mode and bit-rate. (see section 4.2.4.1)
Configuration
Î
Stream
Î
Filtering
Î
General
•
In case that the service filtering strategy is chosen, select the services (see
section
4.2.4.2)
Configuration
Î
Stream
Î
Filtering
Î
Service
•
In case that the PID filtering strategy is chosen, select the PIDs (see section
4.2.4.3)
Configuration
Î
Stream
Î
Filtering
Î
PID
F
ILTERING THROUGH THE
W
EB
-B
ASED
M
ANAGEMENT
In order to use filtering mode thru the front panel perform the following steps:
•
configure ASI or/and IP outputs to filtering mode:
Stream
Î
General
Î
Output
Î
ASI Output Source
Î
After Filtering
Stream
Î
General
Î
Output
Î
IP Output Source
Î
After Filtering