Chapter 5 Maintenance and Troubleshooting
AC Power Supply Fuse
© 2015 Harmonic Inc. All rights reserved.
41
Electra 9200, Rev O
To replace the filter:
1.
With your fingers on the corners of the filter (indicated in red), push down on the filter
until it is secure in the chassis, as shown in
. The corners of the filter should
press against the chassis when it is fully inserted.
Figure 5–4: Replacing the Air Filter
AC Power Supply Fuse
Single power supply models of the Electra 9200 encoder use a slow blow 4.0 A, 250 V fuse,
5 x 20 mm. The fuse is located on the back panel beside the power input. A spare fuse is
located in the fuse cover, shown in
Figure 5–5: Fuse Cover and AC Power Input
NOTE:
No fuse is available on dual power supply models of the Electra 9200 (ELC-9200D).
Replacing the Power Supply Fuse
To replace the fuse:
1.
Unplug the power cord from the chassis.
DANGER:
You must disconnect the power cord before removing the fuse.
2.
Pull down the fuse cover.
3.
Remove the old fuse.
(RN-11)
Fuse cover
Содержание Electra9200
Страница 1: ...Electra 9200 Multichannel Encoder Installation Guide Rev O...
Страница 115: ...2015 Harmonic Inc All rights reserved...