background image

23

Dry Seasoned Wood Only!

TL2.0 Woodburning Stove

Save These Instructions

Harman®  •  TL2.0 Owner's Manual_R20  •  2011 -___  •  09/15

A. Fuel Specifications

Select only 

dry, seasoned wood

. Wood for burning should 

never be exposed to rain or extremely damp conditions. 

Hardwoods are favored because they are heavier and 

contain more heating capacity (BTU’s) per load than do 

softwoods. Fuel wood should be split and stored under cover 

for “seasoning” - at least a year is recommended. Your stove 

is not an incinerator - do not burn garbage, painted or treated 

wood, plastic, or other debris.
Keep the area around the stove free from clutter. Keep 

all combustibles, including fuel, beyond the code-required 

clearance distance (48" or 1215mm in the U.S., 1525mm or 

60" in Canada). Never store fuel in front of the stove where 

it could interfere with door operation, safe loading, and ash 

removal.

B. General Operating Information

Draft: 

Before you install and/or operate your wood stove, please 

read the entire contents of this manual. Pay particular attention 

to the explanation of draft and its effect on stove performance in  

the Installation section. By following the installation and 

operating guidelines, you will ensure proper draft and gain 

maximum efficiency and enjoyment from your stove.

Do not alter the position of the andirons. Building a fire 

too close to the glass may cause damage to the glass, 

creating a serious risk of fire and property damage.

Doors: 

Your stove has a large glass-paneled door for loading 

and fire viewing, a separate smaller door for removing ashes 

and a top loading door. 

Front Door

Before opening, always check for wood, embers, or ash that 

may be ready to fall out of the door. 

To open the glass door, open the bypass damper first, then 

turn the handle clockwise and pull out; to close the door, 

push the door closed with the handle in the open position, 

then turn, counter-clockwise, to engage the latch. 

Ash Door

To open the ash door, lift up the handle and pull out. Close the 

door by pushing in and pushing the handle all the way down. 

Top Load Door

To open the top load door, open the bypass damper and then 

lift to open the top load door.
All doors must be closed while the stove is in normal 

operation, and the gaskets routinely examined for wear and 

replaced when necessary. Good door seals are important 

for maintaining control of the stove. Never operate with the 

ash door open. Operating the stove with the ash door open, 

or with a door inadequately sealed, could create a serious 

overfiring condition (discussed later in this section).

The glass used in your stove is manufactured to exact 

standards to withstand the high heat of the fire, but like all 

glass, it must be treated with common sense and care. Never 

abuse the glass by slamming the door shut or striking the 

glass with a heavy object. If the glass is broken or damaged, 

do not operate the stove until it has been replaced 
(See instructions in the Maintenance section.)

Operating Instructions 

"NEVER USE GASOLINE, GASOLINE-TYPE LANTERN 

FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR 

SIMILAR LIQUIDS TO START OR "FRESHEN UP " A 

FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS 

WELL AWAY FROM THE HEATER / FIREPLACE STOVE 

WHILE IT IS IN USE".

WARNING

!

CAUTION

!

Approved for use with wood fuel only. The use of any 

other fuel will void the product warranty and may 

cause damage to the appliance and/or your home.

CAUTION

!

ALWAYS WEAR FIRE RETARDANT GLOVES WHEN 

OPERATING THE STOVE.

SAFETY NOTICE

IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, 

OPERATED AND MAINTAINED, A HOUSE FIRE MAY 

RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION 

DIRECTIONS. CONTACT LOCAL BUILDING OR 

FIRE OFFICIALS ABOUT RESTRICTIONS AND 

INSTALLATION INSPECTION REQUIREMENTS IN 

YOUR AREA.
DO NOT BURN GARBAGE OR FLAMMABLE LIQUIDS 

SUCH AS GASOLINE, NAPTHA, OR ENGINE OIL.

Содержание TL2.0

Страница 1: ...ay CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing fur...

Страница 2: ...E SURFACES A Entre le mur lateral et l appareil 356mm b Entre le mur arriereet l appareil 330mm C Entre le tuyau et le mur lateral 610mm d Entre le tuyau et le mur arriere 457mm E Entre le mur adjacen...

Страница 3: ...Use Checklist 8 Section 4 Dimensions Clearances A Appliance Dimensions 9 B Clearances to Combustibles 10 C Floor Protection 12 Section 5 Chimneys Venting A Draft 13 B Chimney Connectors 13 C Wall Pass...

Страница 4: ...ertified to comply with 2015 particulate emission standards Not approved for sale after May 15 2020 MODEL TL2 0 Woodburning Stove LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S 29 2 TYPE Solid...

Страница 5: ...crease ventilation by opening windows or doors 2 Make sure the stove doors and lid are closed and latched 3 Check stove for smoking or puffing condition Open by pass and increase air flow to firebox i...

Страница 6: ...ration must be given to safety convenience traffic flow and the fact that the appliance will need a chimney and chimney connector It is a good idea to plan your installation on paper using exact measu...

Страница 7: ...nstructions Harman TL2 0 Owner s Manual_R20 2011 ___ 09 15 C Component Locations Top Load Opening Air Control Front Load Door Top Load Door Bypass Damper Control Handle Ash Door Ash Door Latch Front L...

Страница 8: ...1 Place the appliance in a location near the final installation and follow the procedures below 2 Open the appliance and remove all articles packed inside Inspect all items for shipping damage Notify...

Страница 9: ...oodburning Stove Save These Instructions Harman TL2 0 Owner s Manual_R20 2011 ___ 09 15 A Appliance Dimensions 25 7 8 657mm 26 7 8 665mm 32 5 16 820mm 35 5 16 897mm Air Intake 9 1 8 231mm 4 Dimensions...

Страница 10: ...C Vent Pipe to Side Wall 24 640mm 24 610mm D Vent Pipe to Back Wall 18 457mm 12 305mm Corner Installation E Corner to Adjacent Wall 16 406mm 10 254mm F Connector to Wall 22 1 2 457mm 16 1 2 419mm For...

Страница 11: ...ipe to Side Wall 23 584mm D Vent Pipe to Back Wall 18 457mm E Vent Pipe to Ceiling 16 406mm Corner Installation F Corner to Adjacent Wall 16 406mm G Connector to Wall 22 1 2 571mm For clearance reduct...

Страница 12: ...on dimensions for the front and sides are measured from the appliance door opening in The United States In Canada the side dimension is measured from the widest part of the appliance Parallel versus C...

Страница 13: ...pond to the size of the flue collar opening which is 6 152mm Do not use makeshift compromises No part of the chimney connector may pass through an attic or roof space closet or other concealed space o...

Страница 14: ...m above the highest point at which they exit from the roof Then the chimney must extend 2 ft 0 6m above the highest point within a 10ft 3m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exi...

Страница 15: ...Protection in this section Since many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your fireplace chimney is behind a combus...

Страница 16: ...ough an Attic or Roof Space Closet or Similar Concealed Space a Floor or Ceiling Chimney Connector Minimum air space with chimney listing Chimney support Attic radiation shield Chimney sections Chimne...

Страница 17: ...ns Harman TL2 0 Owner s Manual_R20 2011 ___ 09 15 Chimney Connector Cathedral style chimney support Finishing collar Roof radiation shield Chimney cap Sealed storm collar Roof flashing Factory Built m...

Страница 18: ...ce Closet or Similar Concealed Space a Floor or Ceiling Minimum clearance to unprotected ceiling 15 Chimney connector sealed at thimble Flue liner with required air space Minimum of three sheet metal...

Страница 19: ...led Space a Floor or Ceiling Minimum clearance from chimney connector to uprotected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney o...

Страница 20: ...cone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior 8 Installation shall be in accordance with the Manufactured Home and Safety St...

Страница 21: ...de the other end of the metal intake flex pipe into the stub on the rear of the stove and secure it with aluminum tape This air intake will supply outside air for the secondary combustion 7 Secure the...

Страница 22: ...is best to remove the door by lifting from the hinges Lay the door down flat on it s face Drill the dimpled holes in each corner of the door and re install the door onto the stove From the outside in...

Страница 23: ...he door push the door closed with the handle in the open position then turn counter clockwise to engage the latch Ash Door To open the ash door lift up the handle and pull out Close the door by pushin...

Страница 24: ...ntent in the wood fuel Ash remains after the burning is complete Within the primary firebox two or more of these stages of combustion are occurring at once Always be sure to provide adequate ventilati...

Страница 25: ...g door s Allow this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 80mm size range making sure that the fuel bed is all...

Страница 26: ...e ashes from the fire chamber periodically by raking a poker across the bottom grates Excessive ash buildup can prevent proper venting of exhaust gases Do not allow the ash pan to over fill Ash buildu...

Страница 27: ...aters must be cleaned regularly as soot ash and creosote may accumulate ALWAYS WEAR FIRE RESISTANT GLOVES TO OPERATE THE STOVE THE AIR CONTROL IS HOT WHILE IN OPERATION CAUTION When properly maintaine...

Страница 28: ...posed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have completely cooled Other waste shall not be placed in this container Gla...

Страница 29: ...ousing Alternately with some minor disassembly you can use a vacuum and or brush to clean the blower wheel Reinstall the blower and tighten the four bolts securely Chimney Connector Frequency As neces...

Страница 30: ...se Instructions Harman TL2 0 Owner s Manual_R20 2011 ___ 09 15 Variable Speed Switch Power Cord Blower Thermostat Grounded to housing Black Wire White Wire 2 1 TL2 0 TL2 6 Optional Blower Kit 1 00 856...

Страница 31: ...08560 Service Parts TL2 0 Beginning Manufacturing Date Sept 2011 Ending Manufacturing Date Active Part number list on following page Wood Stove 1 90 856000 1 Black W Pedestal 08 15 2 3 1 4 6 7 8 9 10...

Страница 32: ...49145 Y Gasket 1 Single Ply Tape 10 Ft 1 00 88100 Y 3 Firedome Plus Combustion Package w Gaskets 3 40 358110 Y Gasket brick air Pkg of 4 3 44 2500202 4 Y Gasket Set Complete 3 44 358110 Y 4 Rear brick...

Страница 33: ...1 00 856008 Y 19 Air control weldment 1 10 856004W Y 20 Air slide 1 10 856003W Y 21 Ash pan 1 10 856006A Y 22 Combustion shoe brick 3 40 00100 Y Shoe brick gasket 3 44 06951 Y 23 Side brick insulatio...

Страница 34: ...5 Zinc Hex Pkg of 100 3 30 1110 100 Y Cap Screw 5 16 18 x 1 2 Grade 5 Zinc Plated Hex Pkg of 50 3 30 1122 50 Y Cap Screw 1 4 20 x 3 8 Grade 5 Zinc Hex Pkg of 25 3 30 1106 25 Y Cap Screw 5 16 18 x 3 4...

Страница 35: ...In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distrib...

Страница 36: ...ED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surf...

Страница 37: ...Save These Instructions Harman TL2 0 Owner s Manual_R20 2011 ___ 09 15 3 90 08560 Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 38: ...________________________________________________________________________________ ________________________________________________________________________________ _____________________________________...

Отзывы: