background image

21

Save  These  Instructions                                                                                                                             

TL2.6 Woodburning Stove

Dry Seasoned Wood Only!

Harman®  •  TL2.6 Owner's Manual_R25  •  2011 -___  •  09/15

A. Mobile Home Installation

Mobile home approval - U.S. only.

DO NOT INSTALL IN A MOBILE HOME IN CANADA.

1.  An outside air inlet must be provided for combustion 

air, and must remain clear of leaves, debris, ice, and/or 

snow. The outside air path must be unrestricted while 

the appliance is in operation. Use Kit #1-10-856082 to 

attach to unit.

2.  The combustion air intake system must be of metal 

construction. It must permit zero-clearance to 

combustible materials, and contain a rodent screen.

3.  The appliance must be secured to the mobile home 

structure  by  bolting  it  to  the  floor.  There  are  holes 

provided in the pedestal model, with the leg model you 

will need to use the retainers from the original pallet. 

Secure with the proper length lag bolts, through the 

hearth pad and into the home floor. 

4.  The appliance must be grounded to the metal framing 

of the mobile home

5. 

All  clearances  to  combustibles  and  floor  protection 

requirements must be followed.

6.  Follow the vent manufacturer's instructions when 

installing in a mobile home. Must be connected to a 

UL103 HT ventilated chimney connector, UL103 HT 

chimney, and terminal cap with spark arrestor. 

7.  Use silicone to create an effective vapor barrier at 

the location where the chimney or other component 

penetrates to the exterior.

8.  Installation shall be in accordance with the Manufactured 

Home and Safety Standard (HUD) CFR 3280, Part 24

9.  The appliance must never be installed in a room 

designated for sleeping.

10. Burn wood only. Other fuels may generate poisonous 

gases (carbon monoxide).

11.  If unit burns poorly while an exhaust blower (range 

hood) is operating, increase the supply of combustion 

air to the appliance

INSTALLATION MUST COMPLY WITH 

MANUFACTURED HOME AND SAFETY STANDARD 

(HUD), CFR 3280, PART 24.

NOTE: 

The top sections of the chimney must be removable 

to allow a maximum clearance of 13-1/2 feet (411cm) from 

ground level for transportation purposes.

DO NOT INSTALL IN SLEEPING ROOM.

Section 6 - Mobile Homes

THE STRUCTURAL INTEGRITY OF THE MOBILE 

HOME FLOOR, WALL AND CEILING/ROOF MUST BE 

MAINTAINED.
DO NOT CUT THROUGH:

•  FLOOR JOIST, WALL STUDS, OR CEILING 

TRUSSES.

•  ANY SUPPORTING MATERIAL THAT WOULD 

AFFECT THE STRUCTURAL INTEGRITY.

CAUTION

!

WARNING

!

Chimney Connector

Minimum air space 

with chimney listing

Chimney support

Attic radiation shield

Chimney sections

Chimney cap

Storm collar

Roof flashing

Roof radiation 

shield

Outside 

Air

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

Содержание TL 2.6

Страница 1: ...PERMITS HOT WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL IT IS COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS KEEP CHILDREN AWAY CAREFULLY SUPERVISE CHILDREN IN SAME ROOM AS FIREPLACE ALERT CHILDREN AND ADUL...

Страница 2: ...le ou d autres liquides inflammables AVERTISSEMENT Risque d incendie ne pas fonctionner avec chargement de combustible ou d enl vement de cendres portes ouvertes Ne pas stocker carburants ou de combus...

Страница 3: ...le Home Installation 21 Section 7 Appliance Set Up A Outside Air Attachment 22 B Leveling the Appliance 22 C Optional Cooking Grill 22 D Optional Blower Kit 23 E Brushed Stainless Trim Option 23 Secti...

Страница 4: ...Certified to comply with 2015 particulate emission standards Not approved for sale after May 15 2020 MODEL TL2 6 Woodburning Stove LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S 30b 6 2 TYPE S...

Страница 5: ...dows or doors 2 Make sure the stove doors and lid are closed and latched 3 Check stove for smoking or puffing condition Open by pass and increase air flow to firebox if needed 4 Check chimney for poss...

Страница 6: ...appliance Certain conditions can create negative pressure within the dwelling When this occurs you may have trouble operating the wood stove Worse yet it may be strong enough to allow smoke leakage fr...

Страница 7: ...ff the rear shield by removing the four bolts near each corner of the safety label The flue cover plate and the flue collar have the same 2 bolt pattern Switch the two of them by removing the nuts fro...

Страница 8: ...ey meets the minimum height requirements 10 All labels and hang tags have been removed from the glass 11 All plated surfaces have been wiped clean if applicable 12 The optional air distribution blower...

Страница 9: ...nce Dimensions Section 4 Dimensions and Clearances 23 15 16 607mm 34 7 8 885mm 36 11 16 935mm 25 7 8 657mm 34 9 16 888mm 32 3 4 832mm 25 7 8 657mm Outside Air Kit 9 5 16 236mm 29 1 2 749mm C L Outside...

Страница 10: ...d Fuel Burning Appliances Vertical Venting Configuration Location Single Wall Pipe Double Wall Pipe A Unit to Side Wall 17 432mm 15 381mm B Unit to Back Wall 17 432mm 15 381mm C Vent Pipe to Side Wall...

Страница 11: ...rances for Solid Fuel Burning Appliances for clearance from the top of the unit to ceiling This unit was not tested for installation into an Alcove Follow NFPA 211 Table 13 6 1 Clearances for Solid Fu...

Страница 12: ...of the stove A corner installation is one in which the back of the stove is positioned diagonally across a corner of the room Each installation requires its own set of clearances For corner installat...

Страница 13: ...e collar opening which is 6 inches Do not use makeshift compromises No part of the chimney connector may pass through an attic or roof The Chimney Connector Shall Not Pass Through an Attic or Roof Spa...

Страница 14: ...olid fuel chimneys extend 3 ft 0 9m above the highest point at which they exit from the roof Then the chimney must extend 2 ft 0 6m above the highest point within a 10ft 3m radius Thus the 3 foot 2 fo...

Страница 15: ...Protection in this section Since many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your fireplace chimney is behind a combus...

Страница 16: ...led Space a Floor or Ceiling Chimney Connector Minimum air space with chimney listing Chimney support Attic radiation shield Chimney sections Chimney cap Storm collar Roof flashing Roof radiation shie...

Страница 17: ...ce Closet or Similar Concealed Space a Floor or Ceiling Minimum clearance to unprotected ceiling 15 Chimney connector sealed at thimble Flue liner with required air space Minimum of three sheet metal...

Страница 18: ...of Space Closet or Similar Concealed Space a Floor or Ceiling Combustible Floor Airtight insulated clean out Flue liner with required air space Floor Protection Stainlesssteel chimney connector must e...

Страница 19: ...Concealed Space a Floor or Ceiling Combustible Floor UL1777 Stainless steel liner system or other approved lining system Floor Protection Follow liner manufacture s instructions on insulation and supp...

Страница 20: ...y connector to uprotected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 clearance for interior chimney and 2 clearance for NFP...

Страница 21: ...inal cap with spark arrestor 7 Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior 8 Installation shall be in accordance w...

Страница 22: ...ide the other end of the metal intake flex pipe into the stub on the rear of the stove and secure it with aluminum tape This air intake will supply outside air for the secondary combustion 7 Secure th...

Страница 23: ...eces Load door trim Ash lip trim and the Ash door frame To install the load door trim it is best to remove the door by lifting from the hinges Lay the door down flat on it s face Drill the dimpled hol...

Страница 24: ...open the ash door lift up the handle and pull out Close the door by pushing in and pushing the handle all the way down Top Load Door To open the top load door open the bypass damper and then lift to...

Страница 25: ...bustion air enters at the bottom front of the stove where it travels upward through channels at either side of the front door From the manifold located above the front door it is directed into the fir...

Страница 26: ...e loading door s Allow this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 80mm size range making sure that the fuel be...

Страница 27: ...of 900 F 1100 F indicate that the stove is normally ready for Firedome mode With the Firedome engaged temperatures of 500 F 800 F indicate the unit is burning properly and no adjustment is necessary...

Страница 28: ...years of trouble free service Contact your dealer to answer questions regarding proper operation trouble shooting and service for your appliance Visit www harmanstoves com to find a dealer We recommen...

Страница 29: ...lass should be obtained only through your Harman dealer To replace a broken glass first be sure to carefully remove the broken glass and any remaining shards or pieces With the door laying on a flat s...

Страница 30: ...ousing Alternately with some minor disassembly you can use a vacuum and or brush to clean the blower wheel Reinstall the blower and tighten the four bolts securely 5 Chimney Connector Frequency As nec...

Страница 31: ...d Wood Only Harman TL2 6 Owner s Manual_R25 2011 ___ 09 15 Variable Speed Switch Power Cord Blower Thermostat Grounded to housing Black Wire White Wire 2 1 TL2 0 TL2 6 Optional Blower Kit 1 00 856002...

Страница 32: ...9 15 Service Parts TL2 6 W Pedestal Beginning Manufacturing Date Sept 2011 Ending Manufacturing Date Active Part number list on following page Wood Stove 1 90 857000 1 2 3 1 4 5 6 7 8 9 10 11 13 12 14...

Страница 33: ...Damper gasket 30 ft 1 00 00888 Y Damper Shaft Retainers Hardware Set of 2 1 00 249145 Y Damper Only 1 10 249107 Gasket 1 Single Ply Tape 10 Ft 1 00 88100 Y 5 Firedome Plus Combustion Package with Gask...

Страница 34: ...an 1 10 857002A Y 22 Combustion shoe brick 3 40 00100 Y Shoe brick gasket 3 44 06951 Y 23 Side brick insulation Qty 2 req 3 40 857054 Y 24 Right side panel painted 2 00 857021B Y 25 Heat shield mounti...

Страница 35: ...30 1110 100 Y Cap Screw 5 16 18 x 1 2 Grade 5 Zinc Plated Hex Pkg of 50 3 30 1122 50 Y Cap Screw 1 4 20 x 3 8 Grade 5 Zinc Hex Pkg of 25 3 30 1106 25 Y Cap Screw 5 16 18 x 3 4 Grade 8 Plain Finish Hex...

Страница 36: ...Service Parts TL2 6 w Legs Beginning Manufacturing Date Sept 2011 Ending Manufacturing Date Active Part number list on following page Wood Stove 1 90 858000 1 08 15 1 2 3 7 6 5 4 8 9 10 11 12 13 14 1...

Страница 37: ...Wooden handle for damper w hardware Pkg of 2 1 00 00249 Y 6 Damper Elbow painted 3 50 00500S Y 7 Damper shaft bushing plates w hardware Inner outer 1 00 856061 Y 8 Damper rod weldment 1 10 856011W Y...

Страница 38: ...ntrol weldment 1 10 856004W Y 22 Air slide 1 10 856003W Y 23 Shoe brick gasket 3 44 06951 Y 24 Bottom Heat Shield 1 00 857056 25 Queen Ann Leg painted w Hardware Qty 4 req 1 00 7000551 Y 26 Right side...

Страница 39: ...1110 100 Y Cap Screw 5 16 18 x 1 2 Grade 5 Zinc Plated Hex Pkg of 50 3 30 1122 50 Y Cap Screw 1 4 20 x 3 8 Grade 5 Zinc Hex Pkg of 25 3 30 1106 25 Y Cap Screw 5 16 18 x 3 4 Grade 8 Plain Finish Hex P...

Страница 40: ...In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distrib...

Страница 41: ...ED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surf...

Страница 42: ...Save These Instructions 3 90 08570 Harman TL2 6 Owner s Manual_R25 2011 ___ 09 15 Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 43: ......

Страница 44: ...________________________________________________________________________________ ________________________________________________________________________________ _____________________________________...

Отзывы: