10
Dry Seasoned Wood Only!
TL2.6 Woodburning Stove
Save These Instructions
Harman® • TL2.6 Owner's Manual_R25 • 2011 -___ • 09/15
B. Clearances To Combustibles
C
A
*D
B
F
E
E
F
C
A
D
B
E
G
F
For clearance reduction methods, refer to NFPA 211 or Local Codes
Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–Burning Appliances" for clearance from the top of the
unit to ceiling.
This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–
Burning Appliances".
Vertical Venting Configuration
Location
Single-Wall Pipe
Double-Wall Pipe
A
Unit to Side Wall
17" / 432mm
15" / 381mm
B
Unit to Back Wall
17" / 432mm
15" / 381mm
C
Vent Pipe to Side Wall
27" / 686mm
25" / 635mm
D
Vent Pipe to Back Wall
20" / 508mm
18" / 457mm
Corner Installation
E
Corner to Adjacent Wall
14-1/2" / 368mm
12" / 305mm
F
Connector to Wall
23" / 584mm
20-1/2" / 521mm
Vertical Vent, Horizontal Exit
Location
Single-Wall Pipe
A
Unit to Side Wall
15" / 381mm
B
Unit to Back Wall
14" / 355mm
C
Vent Pipe to Side Wall
25" / 635mm
D
Vent Pipe to Back Wall
17" / 432mm
E
Vent Pipe to Ceiling
15" / 381mm
Corner Installation
F
Corner to Adjacent Wall
14-1/2" / 368mm
G
Connector to Wall
23" / 584mm