9

mAINTENANCE

grATES

grATE lINK

ShAKEr 

bAr

ShAKEr 

hANdlE

(external)

Close-up view of grate system components

Periodic and Normal Everyday maintenance

Blower Motor- Clean periodically to remove pet hair 

and lint from the intake and fan.

Grates- Keep ash pan empty.
CAUTION: BEFORE CLEANING THE CHIMNEY AND 

SMOKE PIPE, BE SURE THE FIRE IS OUT AND THE 

STOVE IS COOL.

Avoid Chimney Fires. On a regular schedule, check 

for creosote and soot buildup in the chimney, smoke 

pipe, and spiral chamber. These areas must be kept 

clean. Keep a professional chimney sweep in mind.

Steel brushes are the safest for cleaning metal sur-

faces. Salt solutions and some chemical cleaners may 

damage the flue liner. 

To clean the chimney, obtain a stiff brush with an 

extendable handle. Insert the brush  into the chimney 

from the top. Continue brushing and sweeping down

-

ward until the entire length of the chimney is cleaned.

After cleaning the chimney, any debris will be at the 

bottom by the clean-out door. Open the clean-out and 

vacuum the loose debris.

Clean the smoke pipe, from the chimney to the stove, 

using a metal brush. 

Cleaning of the spiral chamber - Remove clean-out 

plate from the front of the stove. Using a 3/4” wrench, 

loosen the clean-out bolt approximately  turns. Slide 

the clean-out plate to one side and remove it from the 

opening. Scrape the spiral chamber with a putty knife 

or similar tool. The residue will fall down to the bot

-

tom of the chamber and can be removed through the 

flue opening on the back of the stove by means of a 

vacuum cleaner or a small scoop.

In the firebox, remove all ashes and vacuum the entire 

firebox. Inspect and replace any cracked firebricks. 

Since coal and coal ashes will draw moisture, it is 

important to thoroughly clean the firebox at the end of 

the heating season. Some users apply a thin coating 

of oil or other rust inhibitor to the inside workings, over 

the summer. The main thing is that you remove all of 

the ash.

Spiral Chamber Cleanout

Cleanout Plate Removed

Содержание SF 250

Страница 1: ...MAY RESULT FOR YOUR SAFETY FOL LOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authorit...

Страница 2: ...Table of Contents Safety Considerations 3 Assembly 4 Installation 5 Chimney Venting 6 Operating Instructions 8 Preventive Maintenance 9 Optional Hot Water Coil 10 Testing Label 12 Warranty 13...

Страница 3: ...rate It has been verified that creosote will ignite at 650 degrees fahrenheit It is the owner s responsibility to follow these recommenda tions This stove consumes air when it is burning if your house...

Страница 4: ...The shaker handle installs onto the shaker handle mount using the two hex bolts and washers provided Firebricks The SF250 uses 14 standard firebricks as shown below These standard firebricks measure 9...

Страница 5: ...hould con sist of 3 8 millboard or a stove board providing equal protection k 84 R 45 The floor protection should extend 8 to the rear and either side and 16 in front of the stove The floor protection...

Страница 6: ...from the stove collar The chimney must be two feet higher than anything within ten feet It also must extend three feet above the point where it intersects or exits the roof line In order to have a pro...

Страница 7: ...uld be no more than two 90 elbows or the equivalent used in connecting the stove to the chimney flue H Shared Flue No more than one appliance shall vent into a single flue The most common cause of poo...

Страница 8: ...in between Loading Coal should only be added when there is a reasonably hot fire The coal bed should be bright and vigorous If the fire is burning hot and there is a deep bed of coals full loads can...

Страница 9: ...After cleaning the chimney any debris will be at the bottom by the clean out door Open the clean out and vacuum the loose debris Clean the smoke pipe from the chimney to the stove using a metal brush...

Страница 10: ...supplied nuts on each leg of the coil Place the coil through the holes in the stove and adjust the nuts so that the pipes stick out about 1 to 1 from the sidewall of the stove Put flat wash ers and nu...

Страница 11: ...2 Circulating pump method Used when the distance is more than ten feet or when the stove is on a higher level than the existing water heater In addition to a circulator you may want to add a aquastat...

Страница 12: ...testing label 12 This appliance is also approved for installation into a shop...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ...15 Notes...

Страница 16: ......

Отзывы: