background image

Harman®  •  PF-120 Owner’s Manual_R3  •  2014 -___  •  10/14

4

3-90-08120c

B.  Limited Lifetime warranty

HARMAN

®

 CENTRAL HEATING PRODUCTS LIMITED wARRANTY

Hearth & Home Technologies Inc., on behalf of its Harman

®

 brand (”HHT”), extends the following warranty for all Harman

®

furnace and boiler products (“Products”) that are purchased from an HHT authorized dealer.

warranty Coverage:

  Subject to the conditions, exclusions and limitations set forth below, HHT warrants to the original 

owner of the Products, and to any transferee taking ownership of the Products at the site of original installation within two 

years following the date of original purchase, that the Products will operate free from defects in material and workmanship 

under normal conditions and use, as described in the operating instructions furnished with the Product, during the warranty 

period described below. HHT will, at its option, repair or replace any Product covered by this warranty that is determined to 

be defective in material or workmanship. 

warranty Period:

  The warranty period runs for six years, except for mechanical and electrical components, which are 

warranted for three years. The warranty period begins on the earlier of:  (i) the date of invoice for the Product; (ii) in the case

of new home construction, the date of fi rst occupancy of the residence or six months after the date of sale of the Product 

by an HHT authorized dealer, whichever occurs fi rst; or (iii) the date 24 months following the date of Product shipment from 

HHT, regardless of the invoice or occupancy date. 

warranty Conditions:

 This warranty applies only to Products:  (i) installed, operated, and maintained as recommended 

in the Product user’s manual; (ii) purchased through an HHT authorized dealer; (iii) while remaining at the site of original 

installation; and (iv) that have not been altered after leaving the factory.

How to File a Claim:

  Claims must be made within the warranty period to the dealer who sold the Product. If that dealer 

cannot provide the warranty service, contact the nearest HHT authorized dealer. Additional service fees may apply if you 

are seeking warranty service from a dealer other than the dealer from whom you originally purchased the Product. Travel 

and shipping charges for parts are not covered by this warranty.

warranty Exclusions:

 This warranty does not cover the following:  (1) consumable and normal wear items, including, 

without limitation, fl ame guides, grates, coal bars, afterburner hoods, fi re brick, gaskets, paint, glass discoloration, burnpot 

housing  weldments,  burnpot  grate  weldments  (pellet  or  corn),  burnpot  front  plates  (pellet  or  corn),  burnpot  front  plate 

locks, corn auger extensions, ceramic inserts, and ceramic insert plates; (2) noise caused by minor expansion, contraction 

or movement of parts; (3) damage resulting from: (i) failure to install, operate or maintain the Product according to the 

installation and operating instructions and listing agent identifi cation label furnished with the Product; (ii) failure to install 

the Product according to local building codes; (iii) shipping or improper handling; (iv) abuse, misuse, continued operation 

with damaged, corroded or failed components, accident, or incorrectly performed repairs; (v) environmental conditions, 

inadequate ventilation, negative pressure or drafting caused by tightly sealed construction, insuffi cient make-up air supply, 

or handling devices such as exhaust fans or forced air furnaces or other such causes; (vi) use of fuels other than those 

specifi ed in the operating instructions; (vii) installation or use of components or accessories not supplied with the Product 

or authorized and approved in writing by HHT; (viii) modifi cation of the product not expressly authorized and approved 

by HHT in writing; or (ix) interruptions or fl uctuations of electrical power supply to the Product; (4) non-HHT components 

or accessories used in conjunction with the Product; (5) the Products’ capability to heat a desired space; information is 

provided to assist the consumer and the dealer in selecting the proper Product for the application; consideration must be 

given to Product location and confi guration, environmental conditions, insulation and air tightness of the structure; or (6) 

additional or unusual utility bills incurred due to any malfunction or defect in Products.

Limitations of Liability:

  Repair or replacement in accordance with the provisions of this warranty will be the owner’s 

exclusive remedy for and will constitute HHT’s sole obligation under this warranty, under any other warranty (express or 

implied), or in contract, tort or otherwise. No employee, agent, dealer, or other person is authorized to give any warranty on 

behalf of HHT. TO THE EXTENT ALLOWED BY LAW, HHT MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, 

INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. HHT WILL NOT 

BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING OUT OF DEFECTS IN OR USE OF THE 

PRODUCTS. Some states do not allow exclusions or limitation of incidental or consequential damages, so these limitations 

may not apply to you. This warranty gives you specifi c rights; you also may have other rights, which vary from state to state. 

The duration of any implied warranty is limited to the duration of the warranty period specifi ed herein.

L:\DOCS\JED\HHT\Warranties\Harman Central Heating Products Warranty 6.16.09 CLN

Содержание PF-120

Страница 1: ...ved for wood pellets Burning of any other type of fuel voids your warranty Hot glass will cause burns Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREF...

Страница 2: ...nufactured by Fabriqu par hearth home Technologies Inc 352 Mountain house Road halifax PA 17032 do not ConneCt this unit to A ChiMney Flue serVinG Another APPliAnCe wArninG DO NOT operate with fire ch...

Страница 3: ...7 D Fuel Specification 8 E General Operating Information 9 F Main Operating Control 9 G Before Your First Fire 10 H Wall Control 10 I Low Fuel Sensor 10 4 Operating Instructions A Starting Your First...

Страница 4: ...plates pellet or corn burnpot front plate locks corn auger extensions ceramic inserts and ceramic insert plates 2 noise caused by minor expansion contraction or movement of parts 3 damage resulting fr...

Страница 5: ...elow actions DO NOT Install or operate damaged appliance Modify appliance Install other than as instructed by Hearth Home Technologies Operate the appliance without fully assembling all components Ove...

Страница 6: ...ear Space Warning RISK OF FIRE Do NOT place combustible objects in front or to the sides of the appliance High temperatures may ignite clothing furniture or draperies NOTICE Clearances may only be red...

Страница 7: ...is an approximate temperature and may vary 2 Feed adjuster Sets the maximum feed rate Test Runs all motors at full speed for one minute to check operation After one minute the combustion blower will...

Страница 8: ...el could turn back into sawdust which does not flow properly through the feed system Size Pellets are either 1 4 inch or 5 16 inch 6 8mm in diameter Length should be no more than 1 1 2 inches 38mm Pel...

Страница 9: ...TYPE lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this heater Keepall such liquids wellaway from the heater while it is in use DO NOT BURN GARBAGE G...

Страница 10: ...aces are kept the more efficient the furnace will be Do not burn garbage gasoline naptha engine oil or other inappropriate materials CAUTION G Before Your First Fire 1 Make sure your appliance has bee...

Страница 11: ...4 1 Figure 4 2 Figure 4 3 Odors and vapors released during initial operation Curing of high temperature paint Open windows for air circulation Odors may be irritating to sensitive individuals CAUTION...

Страница 12: ...to what temperature the fan limit control is reading in the plenum When the wall control is satisfied the blower will shut down until the wall control sees a demand for heat 3 Occasionally the applian...

Страница 13: ...servative number and will probably need to be increased if maximum BTU output is desired After you know a feed rate setting that works well for your application use that setting 3 Flip the Igniter Swi...

Страница 14: ...the AUTOMATIC mode the wall control will function as in Auto Light except the fire will not be allowed to go out It will only be allowed to go to a minimum burn rate between the times the wall control...

Страница 15: ...appliance before servicing Smoke spillage into room can occur if appliance is not cool before unplugging Risk of shock if appliance not unplugged before servicing appliance A Proper Shutdown Procedure...

Страница 16: ...nd pull it out of the furnace Lift the handle and use it for carrying the ash pan Close the inner door before disposing of the ashes Disposal of Ashes Ashes should be placed in a metal container with...

Страница 17: ...it is cooled down or cold Remove ash pan Swing the latch handle up until you feel it contact the top of the swing plate Then push upward until you see the burnpot swing out Figure 5 5 Lift the burnpot...

Страница 18: ...ved for easier replacement later Remove the lower baffle plate This baffle is a flat plate that sits on the firebox floor Tip the top edge toward the burnpot and lift up and out of the furnace Note ho...

Страница 19: ...blades and the blower plate sealing overlap Figure 5 13 Note Be careful not to bend the fan blades this will throw the fan blade out of balance or it may rub the inner chamber which may affect the pe...

Страница 20: ...cleaning mechanism Figure 5 15 This cleaning should be done at least once a week although it can be done more frequently The cleaner the heat exchangers are the more efficient the furnace will be Thi...

Страница 21: ...age 3 Blinks Indicates that the ESP Exhaust Sensing Probe has gone out of range too many times If the unit seems to be operating normally Perform a manual reset If the code persists you ll need to cal...

Страница 22: ...roduce more ash the higher burn settings produce less The more it burns on low the more frequent cleaning of the glass is required 4 Glass has turned dirty 4 Excessive build up of ash The lower burn s...

Страница 23: ...t exchanger tubes may need to be cleaned 4 Combination of all the above 5 6 status blink A 6 blink control board status indication is caused by poor or incomplete combustion The circuit board has the...

Страница 24: ...inal disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled Other waste shall n...

Страница 25: ...ponsible for all high limit safety control There are 2 high limits one normal operation high limit and one backup high limit The control has an automatic diagnostic circuit that continuously monitors...

Страница 26: ...nly shut down Your appliance will pulse the blower every few seconds to clear exhaust until the re is out NOTE The UPS provides safe shut down only It is not intended for continued operation Your appl...

Страница 27: ...K DPDT RELAY flange mtd GRAINGER 2XCO2 GREEN GREEN 2 1 4 3 6 5 16 3 AWG PVC CORD CORD CONNECTOR WHITE POWER FROM THE UPS This plugs into the UPS When power fails UPS will supply current to the relay M...

Страница 28: ...nge Hopper Lid 3 31 73325 Gasket Hopper Lid 10 Ft 1 00 00248 Y Gasket Hopper Throat 3 44 677185 Y 3 Fan Control High limit 3 20 23139 Y 4 Combustion Blower 3 21 08639 Y Mounting Plate 1 10 73416 Gromm...

Страница 29: ...00 67900 Y 9MM Silicone Tube 5 Ft 1 00 511427 Y 10 4 Pellet Air Intake Assembly 1 10 06810A 10 5 Gasket Feeder Air Intake Pkg of 6 3 44 72224 6 Y 10 6 UL Feeder Air Intake 1 10 73811W 10 7 Gasket Ultr...

Страница 30: ...10 73695A Y Clean Out Cover 2 Sets 1 00 06623 Y Thumb Screw Pkg of 10 3 31 782108 10 Y Flame Guide 3 00 08534 Y Flame guide insulator 3 44 35263 Y Gasket Burn Pot Pkg of 5 1 00 07381 Y Silicone Gaske...

Страница 31: ...e Igniton 3 20 02679 Y Air Pump Bracket 2 00 853500B Y Igniter Element Pressure Ignition 1 00 10450 Y Inner Ash door Assembly 1 10 73321A Gasket 1 4 Rope Black w PSA Glass 15 Ft 1 00 2312 Y Inner ash...

Страница 32: ...Harman PF 120 Owner s Manual_R3 2014 ___ 10 14 32 3 90 08120c...

Страница 33: ..._____________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________...

Страница 34: ...the Combustion Blower and Feeder Motor for operation 7 Turn Feed Adjuster back to the 4 setting 8 Turn the Temp Dial to the desired temperature 9 Turn all other Furnace Control knobs to the settings...

Отзывы: