Harman® • P43 Installation Manual_R23 • 2008 -___ • 04/14
20
3-90-04301i
5
Appliance Set-Up
Figure 5.1
A. Unpacking
The P43 is bolted (1/4 x 1" hex head bolts) to the skid to
prevent movement during shipping.
To free the stove from the skid you must remove the hold-
down bolts in the rear of the pedestal base using a 7/16”
socket or wrench. Figure 5.1.
B. Removing Rear Cover Panels
The rear cover panels are secured to the stove with three
screws each. Two of the screws need only be loosened, not
removed, to remove the panels. It is recommended that the
rear covers are installed using a 5/16” socket, wrench or nut
driver after the unit is in place and the vent pipe is installed,
to prevent contact with hot or moving parts.
C. Firebrick
Install the single (1) firebrick horizontally on the angle bracket
above the burnpot. Figure 5.2.
D. Flame Guide
Install the cast iron flame guide on top of the burn pot. Make
sure that the flame guide is fully seated on the vertical sides
of the burn pot and that the back of the guide rests against
the body of the stove. Figure 5.3.
INSTALL EXHAUST VENT AT CLEARANCES SPECIFIED
BY THE MANUFACTURER. Most pellet vent pipe requires a
minimum of 1" of clearance to combustible materials although
some can be installed at 1" clearance.
Follow these instructions along with all local codes regarding
installation of this appliance.
Do
NOT
use makeshift compromises when installing this
appliance, serious consequences may result.
With any hearth appliance, installation of smoke detectors
is recommended on every level of the home.
Possible causes of smoke detector activation:
Paint curing process - Open a window near the appliance
for the first few hours of burning.
Exhaust being drawn back inside the dwelling - Outside air
connection to the appliance is necessary.
Vent leakage - All interior seams and joints should be sealed
with silicone where applicable. Follow vent manufacturers
instructions for proper sealing.
Rear Cover
Panel
Shipping Bolts
Note: These same holes are used for
securing the stove in mobile home
installation.
Rear Cover
Panel
Figure 5.2
1 Firebrick
Figure 5.3
Flame guide