background image

16

P43 Pellet Stove

P43  autOMatic  ignitiOn/OPeratiOn

room  temperature  Mode: 

This  setting,  see  above, 

will produce a room temperature of 70 degrees with the 

distribution blower at medium speed.

The  P43  is  a  fully  automatic  stove  that  features  two 

operating modes; 

Stove temperature Mode

 and 

room 

temperature Mode

. In Stove Temperature Mode, you 

select a burn rate and the stove will remain at the same 

burn rate regardless of the room temperature. 
In the Room Temperature Mode the stove constantly 

monitors the temperature in the room and adjusts the 

size of the fire and the heat output of the stove so that the 

room is kept at a constant temperature. Room mode, in 

the AUTO position, has the added advantage of turning 

the stove off if no heat is required and turning the stove 

on again when the room temperature drops below your 

desired room temperature.  

room temperature Mode 

Most consumers use the stove in the Room Temperature 

Mode because it is the easiest and most efficient method 

of  keeping  the  room  at  a  given  temperature.    In  the 

Room Temperature  Mode,  the  Room  Sensing  Probe 

constantly monitors room temperature. As the weather 

changes outside and your home needs varying amounts 

of heat to be at a desired temperature, the stove will 

automatically  increase  fire  size  and  heat  output  so 

that a constant even temperature is maintained. If the 

weather warms up and no heat is required, the stove 

will gradually shut down. When the house cools down, 

the stove will automatically bring the room temperature 

to the precise temperature you desire.
In the Room Temperature Mode you can select either 

auto or Manual modes

 for the 

igniter,

 using the igniter 

toggle  switch.  When  the  toggle  switch  is  in  the Auto 

position, the igniter, located inside the burn pot, is ready 

to automatically light the fire when required.  When the 

toggle switch set to the Manual position the stove can 

be lit manually with either a gel or a wax type fire starter. 

(see lighting instructions on page 19.) With the igniter 

toggle switch set in the Manual position the stove will 

automatically adjust heat output, but the stove will not 

automatically shut down if no heat is required. Instead it 

will go to its lowest setting and remain there. The Manual 

position on the igniter toggle switch lets you light the 

stove manually, should the igniter fail for any reason. 

Secondly if you are using the Harman battery back up 

system, the Manual setting will prevent the stove from 

turning off and on during a power failure, which would 

drain the back up battery.
In the Room Temperature Mode, the distribution blower 

speed can be increased or decreased by adjusting the 

Room Temp/Off/Stove Temp dial between L and H.  As 

output of the stove increases, the speed of the blower 

will increase automatically to insure that more heat is 

transferred out into the room. The distribution blower 

will shut off as the room reaches the set temperature, 

this will prevent overheating of the room.

room temperature Mode

Содержание P43

Страница 1: ...ADA SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOL LOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFI...

Страница 2: ......

Страница 3: ...he surface of the glass door Recommended Non combustible floor protec tion extending beneath any horizontal sections of venting including the T on the back when venting vertically PREVENTION DES INCEN...

Страница 4: ...4 Tested to Test ASTM E1509 04 ULC S627 00 and ULC C1482 M1990 WITHOUT SIDE SHIELDS WITH SIDE SHIELDS Ser 008 DO NOT REMOVE THIS LABEL NE PAS ENLEVER CETTE TIQUETTE MADE IN USA Fabriqu aux U Appareil...

Страница 5: ...vice person Periodic cleaning is required throughout the heating seasonandat the end of each winter for the stove to work efficiently See cleaning instruc tions on page 23 Mobile Manufactured Home S t...

Страница 6: ...ce to combustible materials allthough some can be installed at 1 clearance Rear Cover Panels Shipping Bolts Note These same holes are used for securing the stove in mobile home installation Fig 1 The...

Страница 7: ...k for possible restrictions in the venting configuration or the need for outside air see page 9 For more information on the draft test procedure refer to Page 21 Mobile Home Installation When installi...

Страница 8: ...0 cm above a gas meter regulator assembly when measured from the horizontal center line of the regulator 1 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 J The clearanc...

Страница 9: ...ouse and leaks out at upper levels This air must be replaced with cold air from outdoors which flows into lower levels of the house Vents and chimneys into basements and lower levels of the house can...

Страница 10: ...e outlet is more than 12 from the inlet cover The maximum length run of this pipe is 15 feet If a longer run is needed the size must be increased to 3 Inlet cover part number 1 10 08542 should be used...

Страница 11: ...throughs CAUTION Keep combustible materials such as grass leaves etc at least 3 feet away from the flue outlet on the outside of the building 1 Preferred method This method provides excellent venting...

Страница 12: ...cellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questionable you may want to install a liner as in method 6 In...

Страница 13: ...e sure to use ap proved pellet vent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using th...

Страница 14: ...earances Minimum flue vent configuration It is required that outside air be installed with this venting configuration to reduce smoke and creosote smell in the room in the event of power failure Min a...

Страница 15: ...n off position band except after normal shut down Blinks to indicate errors listed below Indicates power to distribution blower Status light error messages 3 Blinks Indicates that the ESP Exhaust Sens...

Страница 16: ...required the stove will gradually shut down When the house cools down the stove will automatically bring the room temperature to the precise temperature you desire In the Room Temperature Mode you can...

Страница 17: ...he room is already up to temperature The Stove Tempera ture Mode allows you to have a larger fire and a lower sound level without the distribution blower NOTE During the use of this mode if you keep i...

Страница 18: ...first fire or you are trying different pellets set the feed adjuster to 4 Fig 17 This is a conservative number and will probably need to be increased After you know a feed rate setting that works well...

Страница 19: ...ve a large viewing fire without blowing extra heat into the room During operation with the temperature dial set at 5 or less the distribution fan will not operate A 5 on the temperature dial and a 5 o...

Страница 20: ...into the burn pot causing excessive smoke on start up 3 The firebox low pressure switch will not allow the auger motor or the igniter element to operate if the view door or the ash pan door are open 4...

Страница 21: ...not allow the feed motor or the igniter to operate C o m b u s t i o n Motor Speed Control Low draft only set point The small straight screwdriver slot is plastic therefore the unit can be adjusted w...

Страница 22: ...ged components The glass in your Harman stove is a special ceramic glass Do not abuse the glass by striking or slamming the door Never burn the appliance if the door glass is cracked or broken Replace...

Страница 23: ...ld be retained in the closed container until all cinders have thoroughly cooled It is recommended that the stove is cold and shut down when removing the ash pan 1 Lift the latch handle to open the ash...

Страница 24: ...ON FIRE AND MAY ULTI MATELY CAUSE A HOUSE FIRE 9 Use a brush to clean the flue being careful not to damage the ESP probe see Fig 30 The flue goes straight through into the vent pipe Fig 27 therefore...

Страница 25: ...lated male female wire connectors These connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the rear of the feeder...

Страница 26: ...he igniter Poor draft can be caused by blockage in the exhaust excessive build up on the combustion blower fan blades a failed combustion blower or a door or other opening to the firebox not sealed pr...

Страница 27: ...all the above 5 6 status blink A 6 blink control board status indication is caused by poor or incomplete combus tion The circuit board has the ability to track the combustion through feed settings an...

Страница 28: ...AGRAM 18 3 RUBBER CORD DISTRIBUTION BLOWER COMBUSTION MOTOR CONTACTS N O MALE FEMALE CONNECTIONS BONDED TO STOVE BODY GREEN WIRE IS GROUND POWER CORD 18 3 RUBBER CORD WHITE GREEN BLUE GREEN WHITE RED...

Страница 29: ...n one load of pellets The hopper extension adds 60 pounds to the existing hopper capacity allowing you to load 120 pounds of pellets at one time The extension seals to the unit hopper with three latch...

Страница 30: ...ontent takes energy to dry and tends to cool the appli ance thus robbing heat from your home Damp pellet fuel could turn back into sawdust which does not flow properly through the feed system Size Pel...

Страница 31: ...ture knob to desired amount Turn mode selector knob onto Room Temp mode After the fire has lit watch that the fuel does not feed too fast that it pushes the red glowing fuel bed off of the burn pot gr...

Страница 32: ...continued operation Your appliance will recognize when power is restored What happens depends on ESP temperature and whether it is equipped with automatic ignition in automatic setting units equipped...

Страница 33: ...home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occ...

Страница 34: ...as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated...

Страница 35: ...04300 2 charcoal 1 90 04300 3 goldenfire 1 90 04300 4 Metallic blue 1 90 04300 5 honey glo 1 90 04300 10 Mojave red 1 90 04300 12 Forest green beginning Manufacturing date n a ending Manufacturing da...

Страница 36: ...t Air Intake Assembly 1 10 06810A 2 5 Gasket Feeder Air Intake Pkg of 6 3 44 72224 6 Y 2 6 UL Feeder Air Intake 1 10 72222 2 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 2 8 Ultra Feeder Weldm...

Страница 37: ...r Cover Right 2 00 773828 2P Y 11 Comb Intake Weldment 1 10 08516S Y 12 Retainer Assembly 1 10 08533S Y 13 Ash Pan 1 10 7738108A Y 14 Ash Door Assembly 1 10 7738106A 15 Bolt on Hinge 2 00 06952B 16 Ca...

Страница 38: ...use 6 Amp Pkg of 5 3 20 49447 5 Y Gasket 1 4 Rope Black W PSA Per Inch Glass 1 00 2312 Y Gasket 3 8 Rope White LD Per Inch Ash or Load Door 1 00 00888 Y Gasket Burn Pot Tailpipe Pkg of 5 1 00 07381 Y...

Страница 39: ...39 P43 Pellet Stove Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 40: ...Proudly Printed On 100 Recycled Paper...

Отзывы: