Installing the P35i-C Pellet Insert into a Harman Zero Clearance Cabinet
If you don’t have a factory built fireplace or masonry fireplace, the P35i-C Pellet Insert can also be installed into the Harman
Zero Clearance Cabinet, Part # 1-00-774235. This is the
only permissible
way to install the P35i-C Pellet Insert without a
suitable fireplace. After the Harman Zero Clearance Cabinet is installed, type PL vent pipe, wall pass-throughs and terminations
are used (
Note:
Flex pipe is not approved these types of installation). Detailed installation instructions are included with the
Zero Clearance Cabinet. These same installation instructions can also be found on-line at www.harmanstoves.com.
Below are two sample installations using the Harman Zero Clearance Cabinet.
PL Vent Pipe installed through a ceiling.
PL Vent Pipe installed through an exterior wall
Harman Zero Clearance Cabinet
Requirements for Terminating the Venting through an
Exterior Wall.
The clearance to a window or door that may be opened must
be a minimum of 48" to the side and 48" below the window/
door, and 12" above the window/door. (
with outside air
installed, 12” to the side or below
)