8390-784C

Product Specific and Important Safety Information 

A. Appliance Certification

NOTE: 

This installation must conform with local codes. 

In the absence of local codes you must comply with the 

ASTM E 1509-12, ULC-S628-93

 & (UM) 84-HUD

MODEL:

P35i-C Pellet Insert

LABORATORY:

OMNI-Test Laboratories, Inc., PFS-TECO

REPORT NO.

135-S-25-6.2, 0135PN025S, F19-531

TYPE:

Pellet Fueled Insert/Supplementary 

For Residential Use

STANDARD(s):

ASTM E 1509-12 (2017), ULC-S628-00, 

ASTM E 2515-11, ASTM E 2779-10

ELECTRICAL 

RATING:

120 VAC, 60 Hz, Start 3.6 Amps, Run 

1.5 Amps

GLASS 

SPECIFICATION:

5mm mirrored ceramic glass

B. Mobile Home Approved

This appliance is approved for mobile home installations 

when not installed in a sleeping room and when an outside 

combustion air inlet is provided. 
The appliance must be properly grounded to the frame of 

the mobile home and use only listed pellet vent, Class “PL” 

connector pipe. 

A  Harman®  Outside Air  Kit  must  be  installed  in  a  mobile 

home installation.

WARNING

!

Risk of Fire! 

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty and agency listing will 

be voided by the below actions.

C. BTU & Efficiency Specifications

EPA Certification Number:
EPA Certified Emissions:

1.5 g/hr

*LHV Tested Efficiency:

74.2%

**HHV Tested Efficiency:

68.2%

***EPA BTU Output:

9,600 - 28,800

****BTU Input

12,800 - 38,400

Vent Size:

4 Inch

Hopper Capacity:

62 lbs

Fuel

Wood Pellet

NOTE: 

Hearth  &  Home Technologies,  manufacturer  of 

this appliance, reserves the right to alter its products, their 

specifications and/or price without notice.

*Weighted average LHV efficiency using data collected 

during EPA emissions test.

**Weighted average HHV efficiency using data collected 

during EPA emissions test.

***A range of BTU outputs based on EPA Default Efficiency 

and the burn rates from the low and high EPA tests.
****Based on the maximum feed rate per hour multiplied by 

approximately 8600 BTU’s which is the average BTU’s from 

a pound of pellets.

This wood heater has a manufacturer-set minimum low burn 

rate that must not be altered. It is against federal regulations 

to alter this setting or otherwise operate this wood heater 

in a manner inconsistent with operating instructions in this 

manual.

This wood heater needs periodic inspection and repair for 

proper operation. It is against federal regulations to operate 

this wood heater in a manner inconsistent with operating 

instructions in this manual.

DO NOT:

  •  Install or operate damaged appliance
  •  Modify appliance
  •  Install other than as instructed by Hearth & Home 

Technologies

  •  Operate the appliance without fully assembling all 

components

  •  Overfire

  •  Install any component not approved by Hearth & 

Home Technologies

  •  Install parts or components not Listed or approved.
  •  Disable safety switches
Improper installation, adjustment, alteration, service or 

maintenance can cause injury or property damage. 

For assistance or additional information, consult a qualified 

installer, service agency or your dealer.

Harman

®

  is  a  registered  trademark  of  Hearth  &  Home 

Technologies.

This wood heater needs periodic inspection and repair for 

proper operation. It is against federal regulations to operate 

this wood heater in a manner inconsistent with operating 

instructions in this manual.

THE STRUCTURAL INTEGRITY OF THE 

MANUFACTURED HOME FLOOR, WALL, AND 

CEILING/ROOF MUST BE MAINTAINED.

DO NOT INSTALL IN SLEEPING ROOM.

CAUTION

!

The 

P35i-C  Pellet  Insert  is  certified  to 

comply with 2020 EPA particulate emission 

standards.

Содержание P35i-C

Страница 1: ...erfire If any external part starts to glow you are overfiring Reduce feed rate Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may...

Страница 2: ...NTACTMAYCAUSESKINBURNS SEENAMEPLATEANDINSTRUCTIONS KEEP FURNISHINGSAND OTHER COMBUSTIBLE MATERIALSACONSIDERABLE DISTANCE AWAY FROM THIS APPLIANCE KEEP HOPPER LID CLOSED DURING OPERATION FAILURE TO DO...

Страница 3: ...pdated information 3 Reference Materials A Service Parts 15 B Limited Lifetime Warranty 20 C Loss of Power Addendum 22 D Emergency Manual Ignition 22 E Troubleshooting 23 F Contact Information 24 1 Pr...

Страница 4: ...ing EPA emissions test Weighted average HHV efficiency using data collected during EPA emissions test A range of BTU outputs based on EPA Default Efficiency and the burn rates from the low and high EP...

Страница 5: ...information or visit www hpba org safety information To prevent unintended operation when not using your stove for an extended period of time summer months vacations trips etc Unplug stove from recep...

Страница 6: ...Before using the appliance have the venting system thoroughly inspected and replace any damaged components With any hearth appliance installation of smoke detectors is recommended on every level of th...

Страница 7: ...ION Do not burn fuel that contains an additive May cause hopper fire Damage to product may result Read the list of ingredients on the packaging H Fuel Specifications Cont BURNING COLORED PAPER CARDBOA...

Страница 8: ...ll flames with black tails and is lazy The feed rate needs to be reduced or the burnpot needs cleaning Heat exchanger or exhaust blower needs cleaning Smoky start up or puffs of smoke from the airwash...

Страница 9: ...efore unplugging Risk of shock if appliance not unplugged before servicing appliance A Proper Shutdown Procedure CAUTION NOTICE The type of fuel you are burning will dictate how often you have to clea...

Страница 10: ...es into a steel non combustible container with tight fitting lid outside Use provided paint brush Vacuum loose ash from around igniter and inside burn pot Stove MUST be turned off cold and unplugged f...

Страница 11: ...ovided run the straight edge along the flat surface of the Heat Exchanger removing any carbon deposits or ash build up Figure 2 2 Figure 2 2 Scrape the heat exchanger free of Fly Ash and carbon build...

Страница 12: ...r ash as ashes may block conventional vacuum filters 1 Remove the left and right corner cleanout covers by removing the wing screws one per Figure 2 6 2 Brush or vacuum the remaining ash from the fire...

Страница 13: ...Replacement If the stove s glass is cracked or broken you must replace it before operating your stove Remove pieces carefully Replace glass only with Harman replacement glass do not use substitutes C...

Страница 14: ...that can make its way into that area can drastically cut down on the air movement throughout the unit ultimately causing less of a heating efficiency Once the unit is shut down and cooled unplug the...

Страница 15: ...al Service Parts P35i C Pellet Insert Beginning Manufacturing Date Jan 2020 Ending Manufacturing Date Active Pellet Insert 1 70 784195 1 Black 19 5 inch 1 70 784235 1 Black 23 5 inch Part number list...

Страница 16: ...tub Set of 5 1 00 07384 Y 3 Mounting Frame Assembly 1 10 774235A Screw HCS 5 16 18 X 1 Pkg of 12 27887 12 Y 4 Wing Assembly Oversize Black 1 00 774250 1 Standard Black 1 00 774221 1 Custom 1 00 774221...

Страница 17: ...Latch 2 Sets 1 00 0669697 Y 12 3 8X1 2 Silicone PSA 20FT For hopper top 1 00 375501 Y 13 Spring Latch Qty 4 req 3 31 00927 Y 14 Ash Pan W Gasket 1 10 774207 Y Ash Pan Gasket 3 44 774211 Y 15 Ash Pan C...

Страница 18: ...27 UL Feeder Assembly See following page 14 Ft Power cord 3 20 674200 Y 306W 120V Igniter 15 Fin 3 20 677200 Y Pkg of 10 1 00 677200 Y Ash Lip Trim Brushed Stainless 3 43 08400 7 Bright Nickel 3 43 08...

Страница 19: ...r Crossover Kit 1 00 67900 Y 9MM X 13MM Tubing Kit 5 Ft 1 00 511427 Y 27 7 1 8 Silicone Tubing 5 Ft 1 00 5113574 Y 27 8 Screws HWH TEKS 10 X 3 4 Pkg of 100 3 30 5004 100 Y 27 9 Pellet Air Intake w Gas...

Страница 20: ...owever the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for...

Страница 21: ...andling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental conditions inadequate vent...

Страница 22: ...fire is out the ESP temperature will not rise The unit will then shut down and may flash a six blink status error See ESP error codes If the fire is still burning it will resume normal operation Cont...

Страница 23: ...failed Partially burned pellets Feed rate too high Poor air to fuel mixture Check burn pot clean out cover and air intake Burn pot may need to be cleaned Combination of all the above Smoke smell Seal...