Harman® • P35i-C Owner’s Manual_R3 • 2019 -___ • 03/20
14
8390-784C
Figure 2.15
Inspect Hopper Lid gasket
during cleaning and inspection
Inspect all Gaskets-
While the unit is cool, inspect all door gaskets to insure proper
seal. The gasket should be continuous without frays or tears;
having plyable gasket means having a correct seal for proper
operation. Figures 2.14 & 2.15.
Distribution Blower-
Checking the distribution blowers yearly is a good habit to
get into. Dust, animal hair or anything else that can make
its way into that area can drastically cut down on the air
movement throughout the unit ultimately causing less of a
heating efficiency.
Once the unit is shut down and cooled, unplug the unit from
its power supply. Behind each side panel release (1) spring
latches that holds the unit to the inserts cage. Figure 2.16.
Spring Latch
Figure 2.16
Once unit is pulled away from the fireplace, thoroughly
vacuum around the Distribution Blowers. Figure 2.17.
Figure 2.17
Distribution Blowers
Cleaning Venting System-
Its is recommend that a certified chimney sweep perform
service and inspection to your chimney system to insure
your unit is vented safely and in accordance to local code.