Harman P35i-C Скачать руководство пользователя страница 13

Harman®  •  P35i-C Owner’s Manual_R3  •  2019 -___  •  03/20

13

8390-784C

8. Before reinstalling the access cover, make sure the 

insulation between the two layers is in tact.

9.  Whenever the hopper is empty, inspect and remove any 

large  amounts  of  sawdust  or  fines. Although  this  finer 

material will mostly feed through with the fuel, large 

quantities of sawdust may restrict feeder flow.

Exhaust Chamber 

Access Cover

Figure 2.9

Insulation

Figure 2.10

Caring for your Glass-

The  glass  used  in  your  stove  is  manufactured  to  exact 

standards to withstand the high heat of the fire, but like all 

glass, it must be treated with common sense and care. Never 

abuse the glass by slamming the door shut or striking the 

glass with a heavy object. If the glass is broken or damaged, 

do not operate the stove until it has been replaced.

Glass - Replacement

If the stove’s glass is cracked or broken, you must replace 

it  before  operating  your  stove.  Remove  pieces  carefully. 

Replace  glass  only  with  Harman

®

  replacement  glass; 

do 

not use substitutes.

Carefully remove damaged glass, gasket material, and hold 

down clips (set aside). 
Install the self adhesive 1/4”” gasket material around the front 

face of the glass. Set the glass panel and gasket gently onto 

the door. Install the hold down clips and tighten with bolts. 

Glass - Cleaning

Sometimes it will be necessary to clean accumulated ash 

from the glass surface; allowing this ash to remain on the 

glass for long periods can result in “etching” due to the acidity 

of the ash. Never clean the glass while it is hot, and 

do not

 

use abrasive substances. Wash the surface with cool water, 

and rinse thoroughly. You may wish to use a non-abrasive 

cleaner specifically designed for use on stove glass. In any 

case, dry thoroughly before relighting your stove.

Figure 2.14

Retainers and screws

Glass

Adhesive gasket

Door Frame

Содержание P35i-C

Страница 1: ...erfire If any external part starts to glow you are overfiring Reduce feed rate Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may...

Страница 2: ...NTACTMAYCAUSESKINBURNS SEENAMEPLATEANDINSTRUCTIONS KEEP FURNISHINGSAND OTHER COMBUSTIBLE MATERIALSACONSIDERABLE DISTANCE AWAY FROM THIS APPLIANCE KEEP HOPPER LID CLOSED DURING OPERATION FAILURE TO DO...

Страница 3: ...pdated information 3 Reference Materials A Service Parts 15 B Limited Lifetime Warranty 20 C Loss of Power Addendum 22 D Emergency Manual Ignition 22 E Troubleshooting 23 F Contact Information 24 1 Pr...

Страница 4: ...ing EPA emissions test Weighted average HHV efficiency using data collected during EPA emissions test A range of BTU outputs based on EPA Default Efficiency and the burn rates from the low and high EP...

Страница 5: ...information or visit www hpba org safety information To prevent unintended operation when not using your stove for an extended period of time summer months vacations trips etc Unplug stove from recep...

Страница 6: ...Before using the appliance have the venting system thoroughly inspected and replace any damaged components With any hearth appliance installation of smoke detectors is recommended on every level of th...

Страница 7: ...ION Do not burn fuel that contains an additive May cause hopper fire Damage to product may result Read the list of ingredients on the packaging H Fuel Specifications Cont BURNING COLORED PAPER CARDBOA...

Страница 8: ...ll flames with black tails and is lazy The feed rate needs to be reduced or the burnpot needs cleaning Heat exchanger or exhaust blower needs cleaning Smoky start up or puffs of smoke from the airwash...

Страница 9: ...efore unplugging Risk of shock if appliance not unplugged before servicing appliance A Proper Shutdown Procedure CAUTION NOTICE The type of fuel you are burning will dictate how often you have to clea...

Страница 10: ...es into a steel non combustible container with tight fitting lid outside Use provided paint brush Vacuum loose ash from around igniter and inside burn pot Stove MUST be turned off cold and unplugged f...

Страница 11: ...ovided run the straight edge along the flat surface of the Heat Exchanger removing any carbon deposits or ash build up Figure 2 2 Figure 2 2 Scrape the heat exchanger free of Fly Ash and carbon build...

Страница 12: ...r ash as ashes may block conventional vacuum filters 1 Remove the left and right corner cleanout covers by removing the wing screws one per Figure 2 6 2 Brush or vacuum the remaining ash from the fire...

Страница 13: ...Replacement If the stove s glass is cracked or broken you must replace it before operating your stove Remove pieces carefully Replace glass only with Harman replacement glass do not use substitutes C...

Страница 14: ...that can make its way into that area can drastically cut down on the air movement throughout the unit ultimately causing less of a heating efficiency Once the unit is shut down and cooled unplug the...

Страница 15: ...al Service Parts P35i C Pellet Insert Beginning Manufacturing Date Jan 2020 Ending Manufacturing Date Active Pellet Insert 1 70 784195 1 Black 19 5 inch 1 70 784235 1 Black 23 5 inch Part number list...

Страница 16: ...tub Set of 5 1 00 07384 Y 3 Mounting Frame Assembly 1 10 774235A Screw HCS 5 16 18 X 1 Pkg of 12 27887 12 Y 4 Wing Assembly Oversize Black 1 00 774250 1 Standard Black 1 00 774221 1 Custom 1 00 774221...

Страница 17: ...Latch 2 Sets 1 00 0669697 Y 12 3 8X1 2 Silicone PSA 20FT For hopper top 1 00 375501 Y 13 Spring Latch Qty 4 req 3 31 00927 Y 14 Ash Pan W Gasket 1 10 774207 Y Ash Pan Gasket 3 44 774211 Y 15 Ash Pan C...

Страница 18: ...27 UL Feeder Assembly See following page 14 Ft Power cord 3 20 674200 Y 306W 120V Igniter 15 Fin 3 20 677200 Y Pkg of 10 1 00 677200 Y Ash Lip Trim Brushed Stainless 3 43 08400 7 Bright Nickel 3 43 08...

Страница 19: ...r Crossover Kit 1 00 67900 Y 9MM X 13MM Tubing Kit 5 Ft 1 00 511427 Y 27 7 1 8 Silicone Tubing 5 Ft 1 00 5113574 Y 27 8 Screws HWH TEKS 10 X 3 4 Pkg of 100 3 30 5004 100 Y 27 9 Pellet Air Intake w Gas...

Страница 20: ...owever the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for...

Страница 21: ...andling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental conditions inadequate vent...

Страница 22: ...fire is out the ESP temperature will not rise The unit will then shut down and may flash a six blink status error See ESP error codes If the fire is still burning it will resume normal operation Cont...

Страница 23: ...failed Partially burned pellets Feed rate too high Poor air to fuel mixture Check burn pot clean out cover and air intake Burn pot may need to be cleaned Combination of all the above Smoke smell Seal...

Страница 24: ...________________________________________________________________________________ ________________________________________________________________________________ _____________________________________...