background image

Oakleaf Woodburning Stove

Dry Seasoned Wood Only!

Harman®  •  Oakleaf Owner's Manual_R23  •  2010 -___  •  09/15

26

3-90-798

For low burn, slide the air control to the left. For medium 

burns, use notches 1 to 2. Maximum heat is attained with 

the air control all the way to the right. Do not burn the stove 

continuously at the maximum setting. If maximum heat is 

required day after day, the stove is too small for the area 

you are trying to heat.
If  your  wood  is  not  seasoned  long  enough  or  is  high  in 

moisture content, you may need to adjust the primary air 

slightly higher to sustain a low burn rate with the cleanest 

possible exhaust.

E. Before Your First Fire

• 

Be  sure  the  appliance  is  installed  properly  and  that 

all  safety  requirements  have  been  met.  Pay  particular 

attention  to  the  clearances  to  combustibles,  floor 

protection and the venting instructions.

• 

Test your smoke detector(s) and CO detector(s) to the 

specifications of the manufacturer.

• 

Double check that the ash pan and internal firebox are 

empty.

• 

Be sure to read this entire manual.

DO NOT OVERLOAD THE APPLIANCE. DOORS MUST 

BE CLOSED WHEN IN OPERATION

F. Building and Maintaining a Fire

Begin with the bypass damper open, and the air control lever 

at the maximum setting, all the way to the right. Be sure the 

ash pan door is closed and latched. 
Start with a bed of crumpled paper and kindling sized about 

finger width; place several 1" - 2" (25 - 50mm) split pieces of 

dry wood on top of the kindling, followed by a few 2" - 3" (50 

- 80mm) split pieces. Lay the wood in a crossed pattern to 

allow maximum air flow. Ignite the paper and close the loading 

door(s). Allow  this  start-up  fire  to  burn  for  a  few  minutes, 

keeping the bypass damper open. Add about five more pieces 

of wood in the 2 to 3 inch (50 - 80mm) size range, making 

sure that the fuel bed is all the way across the firebox and 

staggered  to  allow  airflow.  Close  the  door  and  allow  this 

loading to burn a few minutes. 
Add increasingly larger pieces of wood to the fire until you 

have a thick bed of hot embers, approximately 2 to 3 inches 

deep at the back of the grate and at least an inch deep at 

the front. 

You must have this charcoal bed established 

before you close the bypass damper.

Providing you have the charcoal bed described, close the 

bypass damper by pulling the handle toward the front of the 

stove. 

D. User Controls

Two important controls - the damper bypass handle and the 

air control lever regulate the operation and output of the stove.
To open the top or front loading door, you must open the 

damper  bypass,  or  smoke  will  come  in  the  room.  In  this 

mode of operation the combustion gases go directly from 

the main combustion chamber to the flue collar and exit into 

the chimney.

NOTE: The bypass damper must be open for smokeless 

loading.

  Open  the  bypass  damper  by  turning  the  handle 

clockwise while facing handle.

Bypass Damper 

Open

Bypass Damper 

Closed

The air control lever is located directly below the load door. 

Sliding  this  lever  allows  you  to  vary  the  amount  of  air  to 

the fire, creating a range of heat outputs. The lowest heat 

output setting is to the left, and the highest is to the right. 

The notches are provided as a reference for your comfortable 

heat  settings.  Do  not,  under  any  circumstances,  alter  the 

configuration or operation of the air control lever.

Minimum 

Primary Air

Maximum 

Primary Air

Содержание Oakleaf

Страница 1: ...to installation Installation MUST comply with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspection requireme...

Страница 2: ...origine am ricaine et pi ces import es E F F E REFER TO MANUFACTURER S INSTRUCTIONS FOR CLEARANCES WITH ADDITIONAL VENT CONFIGURATIONS US ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2015...

Страница 3: ...Component Locator 7 D Flue Direction Conversion 7 E Pre Use Checklist 8 4 Dimensions Clearances A Appliance Dimensions 9 B Clearances to Combustibles 10 C Floor Protection 12 5 Chimneys and Venting A...

Страница 4: ...n standards Not approved for sale after May 15 2020 MODEL Oakleaf Woodburning Stove LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S2 26 6 2 TYPE Solid Fuel Room Heater Wood Burning Type STANDARD...

Страница 5: ...se ventilation by opening windows or doors 2 Make sure the stove doors and lid are closed and latched 3 Check stove for smoking or puffing condition Open by pass and increase air flow to firebox if ne...

Страница 6: ...eded to replace what the chimney draws away through the appliance B Fire Safety Maintain the designated clearances to combustibles Insulation must not touch the chimney You must maintain the designate...

Страница 7: ...ing upward through the firebox and the open bypass damper loosen the retainer bolts on each of the flue collar and the cast iron plate With the bolts loosened turn the retainer to allow the piece to c...

Страница 8: ...clean if applicable 12 The optional air distribution blower has been installed properly 13 A properly grounded electrical receptacle is available within reach of the blower s power cord if installed...

Страница 9: ...27 1 4 692mm 29 1 4 743mm 18 15 16 480mm 25 5 8 650mm Centered 27 5 8 701mm When configured for rear flue Floor to center of flue measures 23 1 2 597mm NOTICE When using rear flue configuration a new...

Страница 10: ...to single wall connector pipe This lower clearance is based on actual safety test conditions E D B C A E F C A C A D B Vertical Venting Configuration Location Single Wall Pipe A Unit to Side Wall 17...

Страница 11: ...Shield Corner to Wall 14 356mm B Vent Pipe to Wall 21 3 4 552mm Location Single Wall Pipe A Shield Corner to Wall 14 356mm B Vent Pipe to Wall 21 3 4 552mm Location Single Wall Pipe A Unit to Side Wa...

Страница 12: ...floor protection USA is 32 5 16 Wide By 43 3 8 Deep Parallel versus Corner Installations A parallel installation is one in which the back and sides of the stove are parallel to the walls behind and to...

Страница 13: ...through an attic or roof space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible wall if you must use an approved wall...

Страница 14: ...he highest point at which they exit from the roof Then the chimney must extend 2 ft 0 6m above the highest point within a 10 ft 3m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exit point...

Страница 15: ...our plans See Clearances and Floor Protection in this section Since many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your fi...

Страница 16: ...ace a Floor or Ceiling Chimney Connector Minimum air space with chimney listing Chimney support Attic radiation shield Chimney sections Chimney cap Storm collar Roof flashing Roof radiation shield SS...

Страница 17: ...thimble Flue liner with required air space Minimum of three sheet metal screws per joint of chimney connector Mantel and trim protection Airtight insulated clean out Damper closed and sealed with non...

Страница 18: ...ld The Chimney Connector Shall Not Pass Through an Attic or Roof Space Closet or Similar Concealed Space a Floor or Ceiling Combustible Floor Airtight insulated clean out Flue liner with required air...

Страница 19: ...ll Not Pass Through an Attic or Roof Space Closet or Similar Concealed Space a Floor or Ceiling Combustible Floor UL1777 Stainless steel liner system or other approved lining system Floor Protection F...

Страница 20: ...pace a Floor or Ceiling Minimum clearance from chimney connector to uprotected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 c...

Страница 21: ...or protection requirements must be followed 6 Follow the vent manufacturer s instructions when installing in a mobile home 7 Installation shall be in accordance with the Manufactured Home and Safety S...

Страница 22: ...wall portion 6 Slide the other end of the metal intake flex pipe into the stub on the rear of the Oakleaf and secure it with aluminum tape This air intake will supply outside air for the secondary co...

Страница 23: ...er on at any time using the rocker switch on the rear of the blower housing Setting the switch to AUTO will keep the blower off until there is a significant amount of heat from the stove In this setti...

Страница 24: ...perating guidelines you will ensure proper draft and gain maximum efficiency and enjoyment from your stove Do not alter the position of the andirons Building a fire too close to the glass may cause da...

Страница 25: ...he ash to fall into the ash pan by passing a poker back and forth across the grate The andirons keep the fuel from coming into direct contact with the glass and keep hot coals and embers from spilling...

Страница 26: ...epaper and close the loading door s Allow this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 80mm size range making su...

Страница 27: ...The ashes should be the coolest at this time Remove ashes from the fire chamber periodically by raking a poker across the bottom grates Excessive ash buildup can prevent proper venting of exhaust gas...

Страница 28: ...chnician A Creosote Formation and Need For Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condens...

Страница 29: ...eplace gasket as needed Do not operate the stove with a broken glass Replacement glass which is ceramic glass should be obtained only through your Harman dealer To replace a broken glass first be sure...

Страница 30: ...dust and pet hair from the blower wheel Reinstall the blower and tighten the two bolts securely 5 Chimney Connector Frequency As necessary Yearly By Qualified Service Technician User At the end of the...

Страница 31: ...kleaf Owner s Manual_R23 2010 ___ 09 15 31 3 90 798 Variable Speed Switch Power Cord Blower Thermostat Rocker Grounded to housing Switch Black Wire White Wire 2 1 Oakleaf Optional Blower Kit 1 00 7970...

Страница 32: ...acturing Date Active Part number list on following page Cast Iron Wood Stove 1 90 797000 1 Black Sept 2010 thru June 2011 1 90 797000 2 Charcoal 1 90 797000 3 Golden re 1 2 7 6 8 23 22 3 4 5 28 27 26...

Страница 33: ...7 Oakleaf Package 3 40 797022 Y Gasket 1 4 Round PSA 15 FT 1 00 2312 Y 8 Ramp Assembly w Gsket 1 10 797109 Y Gasket 1 4 Round PSA 15 FT 1 00 2312 Y 9 Brick Clip Set 1 00 249153 Y 10 Damper Frame Asse...

Страница 34: ...50 3 30 1134 50 Y Bolt CB 5 16 18 X 2 Z Pkg of 25 3 30 4001 25 Y Nut FHN 5 16 18 Z 5 Pkg of 100 3 30 8005 100 Y 21 Base Plate Qty 2 req 2 00 797027S 22 Center Brick 3 40 797020 Y Gasket 1 4 Round PSA...

Страница 35: ...anty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warrant...

Страница 36: ...y does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw...

Страница 37: ...Oakleaf Woodburning Stove Dry Seasoned Wood Only Harman Oakleaf Owner s Manual_R23 2010 ___ 09 15 37 3 90 798 Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 38: ...__________________ ________________________________________________________________________________ ________________________________________________________________________________ ___________________...

Отзывы: