Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15
19
3-90-798
Full Relining Fireplace Conversion: Freestanding Appliance
NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in place
of the existing shield.
The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a
Floor or Ceiling.
Combustible Floor
UL1777 Stainless steel liner system or other
approved lining system
Floor Protection*
Follow liner manufacture’s instructions
on insulation and support
UL1777 insulated stainless steel flex liner
or other approved lining system in offsets
Damper plate is removed or fastened
in open position. Use damper
adapter or seal with non-combustible
material.
*Floor protection in accordance with solid fuel appliance listing