AC power
21
Warning! The MAC Aura XIP does not have a power On/Off switch. As soon as you connect an
energized power input cable to the fixture or apply power to a power input cable that has already
been connected, the fixture will power up: check that there is no safety risk from head movement or
intense light output.
To connect the fixture to AC mains power:
1. See Figure 8. Line up
the keys in the power
input cable connector
with the keyways in the
MAINS IN socket (
A
).
Insert the connector
into the socket and
twist clockwise to
engage. If the
connector seems
difficult to twist, remove
it from the socket,
check that you have
lined up the keyways
correctly and try again
– do not use excessive force. Make sure that the connector latch clicks and that the connector is locked
into the socket.
2. Check that the base is held securely. Be prepared for the fixture to light up and the head to move
suddenly. Apply power to the input cable to power the fixture on.
To disconnect from power, pull the release latch on the power input cable connector towards you to unlock
the connector, twist the connector counter-clockwise, and then withdraw it from the MAINS IN socket.
Linking fixtures to power in a daisy-chain
Warning! If you link fixtures in a daisy-chain so that they all draw AC mains power via the first
fixture, check carefully the Safety Precautions chapter at the beginning of this manual. Use only the
cables and connectors specified. Respect the specified safety limits for the total number of fixtures
that you can connect to power in one interconnected daisy-chain at your local power voltage.
If you obtain a 16/20 A-rated power input cable and 16/20 A-rated power relay cables from Martin (your
Martin supplier can give details of these), you can relay mains power from one fixture to another by
connecting fixtures to power in a linked daisy-chain, MAINS THRU socket (
B
in Figure 8) to MAINS IN
socket (
A
in Figure 8) If you create a daisy-chain link like this, you must respect the safety limits given in the
Safety Precautions chapter at the beginning of this manual, or you may create a risk of fire and electric
shock.
To avoid any unnecessary tripping of miniature circuit breakers when creating a daisy chain, we recommend
that you:
• connect a maximum of five (5) fixtures to mains power in a daisy-chain at 100-120 V when using a 20 A
Type C RCBO with a 10 mA earth leakage rating.
• connect a maximum of eight (8) fixtures to mains power in a daisy-chain at 200-240 V when using a 16 A
Type C RCBO with a 10 mA earth leakage rating.
Figure 8: Mains power connections
B
A
Содержание Martin MAC Aura XIP
Страница 1: ...MAC Aura XIP User Manual with Installation and Safety Manual attached...
Страница 53: ...Control orientation reference 53 Zoom control Zoom Narrow DMX 0 Zoom Wide DMX 65535...
Страница 54: ...www martin com...
Страница 94: ...www martin com...