25
Basic service
Storage Procedure:
Perform the above cleaning and preventative maintenance procedure. After
procedure is completed simply run the machine until all fluid has been visibly
purged from the fluid inlet tubing to prevent leaks and seepage.
Fuse replacement
The main fuse for the machine is located adjacent to the power inlet on the rear
panel. There is also a T3.15 A fuse located on the electronics board inside the
unit which protects the supply to the pump.
DANGER! Disconnect the power supply before removing any covers or changing
fuses. Live parts inside!
Rear panel fuse:
ZR25
120 V = 10 A/250 V
230 V = 6.3 A/250 V
ZR35
120 V = 15 A/250 V
230 V = 10 A/250 V
ZR45
120 V = 20 A/250 V
230 V = 12.5 A/250 V
Replace fuse only with one of exactly the same size and rating. Contact Martin
Service and Support if the fuse blows repeatedly.
To replace the internal fuse, disconnect the power cord from the supply,
unscrew the screws holding the top cover of the unit and remove the cover. The
electronics board is located in the side compartment.