background image

17 

Control settings 

Setting the host-client link mode 

It is possible to control several machines from one digital remote control. The 
machine with the remote plugged into it is set as the Host. The other machines 
are set as Clients. The machines are interconnected with DMX cabling. 
 

Use the Previous / Next buttons to select the LINK MODE option from the 
SETTINGS menu. 
Use the Up/Down buttons to select RECEIVE (client unit) or SEND (host unit). 
Press the ENTER button to store the link setting. 
 
The machine should be set to SEND only if it is running as a host. If running as a 
client, stand-alone or DMX controlled it should be set to RECEIVE. If a machine 
set to SEND is connected to an active DMX system, the DMX will be corrupted 
causing flickering of lights and other strange symptoms. 
 

 

Priming the machine after fluid out 

If the machine runs out of fluid it will automatically shut down and show FLUID 
OUT on the display to prevent damage to the pump(s). To suck the new fluid 
back into the machine and reset the FLUID OUT error, replace/refill the fluid 
reservoir and use the prime function. 
 
Use the Previous / Next buttons to select the PRIME option from the SETTINGS 
menu. 
Use the Up/Down buttons to change the option to YES. 

Press the ENTER button to start the priming function. 
 
The pump(s) will operate at full power for a short time to purge air from the 
pipes inside the unit.  
To exit this menu if you decide not to activate the Prime function, select NO and 
press ENTER.  
To terminate a running prime operation, enter YES and press enter. 
Prime can also be initiated and terminated from DMX channel 2 (in two channel 
mode) 

 

Resetting options to factory settings 

The factory settings configure a standard mode of operation for the machine. 
 
Use the Previous / Next buttons to select the RESET option from the SETTINGS 
menu. 
Use the Up/Down buttons to change the option to YES. 
Press the ENTER button to reset all options. 
 
To exit this menu if you decide not to reset the options, select NO and press 
ENTER. 

 
 

Содержание Martin JEM ZR Series

Страница 1: ...user manual READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...Dimensions Legal All dimensions are in millimeters...

Страница 3: ...quential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Martin and JEM are registered trademarks of HARMAN PROFE...

Страница 4: ...ut density 15 Setting the Timer 16 Using the Settings menu 16 Setting the DMX start address 16 Display back light setting 16 Setting the host client link mode 17 Priming the machine after fluid out 17...

Страница 5: ...ctric shocks Always ground earth the machine electrically Use only a source of AC power that complies with local building and electrical codes and that has both overload and ground fault protection Be...

Страница 6: ...and rating specified in this manual for the machine Provide a minimum free space of 100 mm 4 in around the machine Provide a minimum free space of 500 mm 20 in around fans and air vents and ensure fr...

Страница 7: ...s SKIN Remove contaminated clothing and rinse skin for 20 minutes seek medical attention if irritation persists Consult the fluids SDS for more detailed safety information at www martin com support co...

Страница 8: ...and used at a distance or the machines may be operated by DMX with full RDM capability for remote setup and status monitoring This manual contains instructions for all machines in the range but some...

Страница 9: ...witch Mains power connector Fluid pipe connection Fluid Reservoir Integrated Digital Remote Control Mains fuse Product details ZR25 Fog output nozzle WARNING High temperature vapour and surfaces If su...

Страница 10: ...itch Mains power connector Fluid pipe connection Fluid Reservoir Integrated Digital Remote Control Mains fuse ZR35 Fog output nozzle WARNING High temperature vapour and surfaces If suspending overhead...

Страница 11: ...s power switch Mains power connector Fluid pipe connection Fluid Reservoir Integrated Digital Remote Control Mains fuse ZR45 Fog output nozzle WARNING High temperature vapour and surfaces If suspendin...

Страница 12: ...ear of the unit to the ON I position The display will show HEAT If the display shows OFF press the FOG button on the control panel or set the RUN MODE to CONTINUOUS After about 6 8 minutes the display...

Страница 13: ...ing bolts fitted to the hanging bracket in place of the normal hand wheel bolts Before first use remove the shipping bolts and replace them with the hand wheel bolts outside of bracket and spacers ins...

Страница 14: ...ts stated on page 13 the operator is familiar with and able to comply with the requirements for safe operation listed on page 5 the fluid is one of the approved Martin fluids listed under Approved Fog...

Страница 15: ...o be used to shut down the heater Settings are OFF shutdown heaters off STANDBY heaters remain on TIMER or CONTINUOUS mode Use the Menu Previous Next buttons to select the RUN MODE option Use the Up D...

Страница 16: ...rightness Host Client linking priming factory reset and temperature control ZR45 only are found in the SETTINGS menu Use the Previous Next buttons to select the SETTINGS option Press the Enter button...

Страница 17: ...UID OUT on the display to prevent damage to the pump s To suck the new fluid back into the machine and reset the FLUID OUT error replace refill the fluid reservoir and use the prime function Use the P...

Страница 18: ...The factory settings are option setting FOG LEVEL 50 TIMER ON 10 seconds TIMER OFF 20 seconds RUN MODE STANDBY DMX 001 BACK LIGHT NORM LINK MODE RECEIVE1C PRIME NO TEMPERATURE NORM ZR45 Only...

Страница 19: ...to this state If the machine was set to CONTINUOUS it will revert to this state Connection The JEM ZR series machine provides 5 pin XLR connectors on the rear of the machine for DMX connection For be...

Страница 20: ...efore you can communicate with fixtures using RDM you must send a scan command also called a device discovery command to all the devices on the data link so that the RDM controller can identify them I...

Страница 21: ...ATUS_MESSAGES DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL FACTORY_DEFAULTS DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION DEVICE_HOURS BOOT_SOFTWARE_VERSION_ID BOOT_SOFTWARE_VERSION_LABEL SL...

Страница 22: ...is often preferred JEM Pro Fog Fluid Quick Dissipating offers a less dense effect compared to the benchmark JEM Pro Fog Fluid and is therefore less likely to interfere with video and film camera focu...

Страница 23: ...uid RUSH Fog Fluid RUSH ELX Smoke Fluid Regular DJ Fluid DJ ZR45 Temperature Menu The different fluid types listed require correct selection of the relevant temperature setting in the TEMPERATURE sub...

Страница 24: ...fect heat exchangers This advanced preventative maintenance fluid has been utilized by Martin service technicians for years of both cleaning and storing effect machines Utilizing Martin Pro Clean Stor...

Страница 25: ...inside the unit which protects the supply to the pump DANGER Disconnect the power supply before removing any covers or changing fuses Live parts inside Rear panel fuse ZR25 120 V 10 A 250 V 230 V 6 3...

Страница 26: ...on in DMX line Check DMX cables and connections LINK menu is set to SEND Set LINK menu to RECEIVE Fog output is weak Machine requires priming Use PRIME option to prime the machine page 17 Wet greasy n...

Страница 27: ...e heater is at operating temperature and the unit is under DMX control FLUID OUT Run out of fluid Refill the fluid reservoir and operate the prime function in the SETTINGS menu CALIBRATION ERROR The m...

Страница 28: ...189 ft per minute Fluid consumption max 100 ml per minute Maximum operating time maximum output 2 5 l of fluid 1 2 hours ZR35 Continuous effect output Ready time 9 minutes Coverage volume 800 m 28 25...

Страница 29: ...lation Mounting Standing or hanging Clearance around machine 100 mm 4 in Orientation Up to 40 from horizontal Connections AC Power Neutrik PowerCON TRUE1 DMX Link mode in out 5 pin locking XLR Remote...

Страница 30: ...ON TRUE1 molded NEMA 5 20P 2 m 6 6 ft P N 11501046 Accessories JEM ZR25 Ducting System with 5 m 16 4 ft ducting P N 92625012 JEM ZR35 Ducting System with 5 m 16 4 ft ducting P N 92625013 JEM ZR45 Duct...

Страница 31: ...JEM ZR45 EU P N 92215360 Specifications subject to change without notice For the latest product specifications see www martin com Disposing of this product Martin products are supplied in compliance...

Страница 32: ...www martin com...

Отзывы: