Specifications
Active Junction Box Power-DMX-Ethernet to PDE
Physical
Length ....................................................................... 215 mm (8.5 in.) (incl. mounting flanges)
Width............................................................................................................... 115 mm (4.5 in.)
Height................................................................................................................. 51mm (2.0 in.)
Weight....................................................................................................................1 kg (2.2 lb.)
Control and Programming
Control Protocols ................................ DMX, RDM, Art-Net, RDM over Art-Net, sACN and P3
Protocol Detection......................................................................................................Automatic
Configuration............................................................................. RDM, RDM over Art-Net or P3
Fixture identification ........................................................................... User-settable ID number
DMX Compliance ..........................................................................................USITT DMX512-A
RDM Compliance......................................................................................... ANSI/ESTA E1.20
Art-Net Compliance..................................... Art-Net 1, 2, 3 and 4; including RDM over Art-Net
sACN Compliance....................................................................................... ANSI E1.31 - 2016
Martin P3 Compliance ..................................... P3 System Controller Software 5.1.0 or newer
DMX/RDM Transceiver IN/THRU ...........................................................Opto-Isolated RS-485
DMX/RDM Transceiver OUT ..................................................................Opto-Isolated RS-485
Ethernet Transceiver IN..................... 100/1000Mbit (with fail-safe bypass to Ethernet THRU)
Ethernet Transceiver THRU .................... 100/1000Mbit (with fail-safe bypass to Ethernet IN)
Ethernet Transceiver OUT.......................................................................................10/100Mbit
Firmware Update .................................................................via DMX using Martin Companion
................................................... or via Ethernet using P3 System Controller
Control/User Interface
Device Status......................................................................................... Multi-color status LED
Fixture Test ................Pushbutton to call up test pattern on fixtures connected to PDE output
Construction
Color ................................................................................................................................. Black
Housing Material .......................................................................................................Aluminium
Protection Rating .............................................................................................................. IP 65
RoHS ........................................................................................................................ Compliant
REACH ..................................................................................................................... Compliant
Installation
Orientation .......................................................................................................................... Any
Wallmount ............................................................................................ Using mounting flanges
Trussmount ............. Using half-coupler clamp in M10 threaded hole, max. bolt length 22 mm
Location ................................................................................. indoor or temporary outdoor use
Connections
AC Power input ......................................................... Neutrik powerCON TRUE1 TOP (IP 65)
AC Power thru............................................................ Neutrik powerCON TRUE1 TOP (IP 65)
DMX input ........................................................................ Neutrik XLR 5-pin Male TOP (IP 65)
DMX thru......................................................................Neutrik XLR 5-pin Female TOP (IP 65)
Ethernet input............................................................................Neutrik etherCON TOP (IP 65)
Ethernet thru .............................................................................Neutrik etherCON TOP (IP 65)
AC Power, DMX and Network out ...............................................PDE hybrid connector (IP65)
All connections hot plugging compatible
Electrical
AC power ...............................................................................100-240 V AC nominal, 50/60Hz
Power Supply Unit .......................................................... Auto-ranging electronic switch mode
Maximum power consumption ............................................................................................ 6 W