Harman AXYS TUNNEL IndustryAmp Dante PB-400-DN Скачать руководство пользователя страница 2

AXYS

®

 IndustryAmp-DN User Manual Rev 3.0

201911/IAMPDN_3.0

2

REFERENCE TO EC STATEMENT OF CONFORMITY

This document confirms that products manufactured by 
Harman Professional Kft. bearing the CE label meet all 
the requirements in the EMC directive 2014/30/EU and 
LV directive 2014/35/EU laid down by the Member States 
Council for adjustment of legal requirements. Harman 
Professional Kft. products bearing the CE label comply 
with the following harmonised or national standards: 

EMC:

 

EN 55032:2012/AC:2013   
EN 55035:2017 
EN 50130-4:2011

Safety: 

EN 60065:2014 (edition 8) 

Mains Harmonics:

 

EN 61000-3-2:2014 

Insulation: 

Class1 

Harman Professional Kft. 
Szilva u. 1-3. 
H-7632 Pécs 
Hungary 

  

USER’S NOTICE AND DISCLAIMER

No part of this manual may be reproduced, transmitted, 
transcribed, stored in a database system or translated 
without the express written permission of Harman 
Professional. Documentation kept by the end user for 
back-up purposes is excluded from the above. 

All products and corporate names mentioned in this 
manual may be registered trademarks or copyrights 
of their respective companies. They are used here for 
indicative purposes only. 

The information contained in this manual has been carefully 
checked for accuracy; however no guarantee is given with 
respect to its correctness. Harman Professional accepts no 
responsibility or liability for any errors or inaccuracies that 
may appear in this manual or the products described in it. 

Specifications and information contained in this manual 
are subject to change at any time without notice.

© 1998-2019 Harman Professional Kft. All rights reserved.

Содержание AXYS TUNNEL IndustryAmp Dante PB-400-DN

Страница 1: ...Installation User Manual Applies to Part Numbers TUN 590404 TUN 590804 AXYS IndustryAmp Dante Delivering Clear and Intelligible Messages...

Страница 2: ...ISCLAIMER No part of this manual may be reproduced transmitted transcribed stored in a database system or translated without the express written permission of Harman Professional Documentation kept by...

Страница 3: ...0 Ventilation 10 Connector and Wiring details 11 AC Mains 11 Audio Connections 12 Analogue inputs 12 Amplifier outputs 12 Dante and Control Interface 13 ANS microphone input 13 Failure relay 14 DSP se...

Страница 4: ...receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused for long...

Страница 5: ...analogue inputs plus dual redundant Dante interface 8 x 100W output into 100 ohm load OVERVIEW The AXYS IndustryAmp is a multichannel power amplifier specifically designed for permanent installation i...

Страница 6: ...ge protocol by using the Dante Ethernet interfaces Pilot tone detection ANS Ambient Noise Sensing mic input Surveillance failure relay DSP bypass function Universal power supply 100 240 VAC with activ...

Страница 7: ...mers Load Monitoring Surge Protection Input 1 Out 1 Out 2 Out 3 Out 4 Input 2 Internal Temperature Fan Monitoring Front LED Internal Supplies Mains External Failure Relay Analogue Pilot detect Digital...

Страница 8: ...ut connections may be made The detector will when enabled switch from Input 1 to Input 2 if pilot tone is lost The IndustryAmp incorporates surveillance functions which activate an externally accessib...

Страница 9: ...2 13 14 Wiring details for all the rear connectors can be found in subsequent sections of the manual Not present on PB 400 DN 2 Failure relay connector 3 ANS microphone input 4 Analogue input 1 5 Anal...

Страница 10: ...ontaining a significant quantity of other heat generating equipment see below consideration should be given to climate controlling the room in which the equipment rack is situated Do not install the I...

Страница 11: ...gate why it blew Always replace by a fuse of the same type and rating as indicated on the rear panel and or in the amplifier datasheet NOTE The PowerCon connector should NEVER be plugged in or unplugg...

Страница 12: ...IndustryAmp should always be used wherever possible If driving from an unbalanced source use the same wiring as shown above at the amplifier end but connect the hot core to the signal output and the...

Страница 13: ...increase the distance further A third party Ethernet to fibre interface will be required in these situations The Dante interfaces add digital audio I O and a control method to the IndustryAmp They pr...

Страница 14: ...oving an internal PCB jumper See fig 5 Failure relay In volt free operation CO is connected to NC a failure condition causes CO to be connected to NO When configured for impedance sensing use the impe...

Страница 15: ...Dante xmt 12 Dante xmt 13 Dante xmt 14 Dante xmt 15 Dante xmt 16 Dante xmt 17 Dante xmt 1 Dante xmt 2 Dante xmt 3 Dante xmt 4 Dante xmt 5 Dante xmt 6 Dante xmt 7 Dante xmt 8 To Dante Outputs Dante xmt...

Страница 16: ...han one input is selected to go to the same output then the inputs are summed Autogain The DSP section includes an autogain algorithm which can be set to automatically adjust the overall volume level...

Страница 17: ...to 23 5 kHz and the threshold may be set between 10 dBFS and 60 dBFS The amplifier s action on non detection of a pilot tone can be configured via WinControl A fault condition can be flagged and or th...

Страница 18: ...brated with the normal loads connected to each amplifier channel to establish a reference load current After calibration any partial or total failure of any of the loads or cabling will be registered...

Страница 19: ...of the chassis to ground Always connect this terminal 2 Reduction of RF emission Although the IndustryAmp electronics are well shielded and external connections are decoupled to prevent RF emission fr...

Страница 20: ...www axystunnel com...

Отзывы: