Dante

 and Control Interface

Connections to the Dante

 card are made via RJ-45 

connectors. Either the Port labeled ‘Primary’ or labeled 
‘Secondary’ may be used; if a dual redundant network 
is employed in the installation, then use both ports, 
connecting each to independent Ethernet switches. 
Separate networks are required for Dante

, not only 

separate switches (see Dante

 recommendations). Primary 

and secondary interface cannot be connected to the same 
network.

NOTE:

 A connection to 1 Gb/s network is strongly 

recommended.

Standard pre-made CAT-5e or higher (CAT-6 etc) network 
cables (see note hereafter) may be used to connect 
amplifiers to the local Ethernet switch(es). However, in 
many installations, the network connection from within a 
rack to an Ethernet switch will be via structural cabling. In 
this case, wire mating RJ-45 plugs (not supplied) as shown 
below:

fig.4:  Dante

 Connectors

This is the T-568B standard (preferred), T-568A standard is 
also used and uses different colour mapping

PIN

CAT-5e CORE

1

White + Orange

2

Orange

3

White + Green

4

Blue

5

White + Blue

6

Green

7

White + Brown

8

Brown

The maximum cable run for reliable operation using  
CAT-5e cable is of the order of 100 m.  If longer distances 
are involved, the use of multimode fibre-optic cable is 
recommended. This is generally satisfactory  up to 2 km, 
but repeaters (or the use of single-mode fibre) can be used 
to increase the distance further. A third-party Ethernet-to-
fibre interface will be required in these situations.

The Dante

 interfaces add digital audio I/O and a 

control method to the IndustryAmp. They provide sixteen 
additional audio inputs and seventeen audio outputs, at a 
sampling rate of 48 kHz and bit depths of 16, 24 or 32 bits. 

NOTE:

 Unscreened CAT-5e UTP cable can be 

used, but note that the amplifier may fail to 

preserve its high level of surge immunity and as a 
consequence, will no longer be compliant with the 
standards set out in the EC Statement of Conformity.  
CAT-5e twisted pair cable with an overall foil shield 
(referred to as FTP or F/UTP) is required for compliancy.

ANS microphone input

The IndustryAmp’s DSP card includes an Autogain 
algorithm which adjusts the gain of the amplifier in 
response to ambient noise levels. To accomplish this, an 
external Ambient Noise Sensing (ANS) microphone must 
be connected to the ANS mic input.

Connection is via a 3-pin 3.81 mm-pitch screw terminal 
connector, with the same pinout as the analogue audio 
inputs. See “fig.2:  Analogue Inputs” on page 12 for 
wiring details.

Note the post-preamp ANS mic signal is transmitted on 
channel 17 of the Dante

 interface. This permits an ANS 

mic to be monitored at a remote location.

A suitable AXYS

®

 ANS microphone is available as an 

option (Part No. TUN-ANS). This should be wired using a 
single twisted-pair cable with an overall screen. Connect 
the microphone pair to the ‘+’ and ‘-‘ pins of the Ambient 
Microphone input. The cable’s overall screen should be 
connected to the pin of the Ambient Microphone input 
marked with an earth    (ground) symbol .

Содержание AXYS TUNNEL IndustryAmp Dante PB-400-DN

Страница 1: ...Installation User Manual Applies to Part Numbers TUN 590404 TUN 590804 AXYS IndustryAmp Dante Delivering Clear and Intelligible Messages...

Страница 2: ...ISCLAIMER No part of this manual may be reproduced transmitted transcribed stored in a database system or translated without the express written permission of Harman Professional Documentation kept by...

Страница 3: ...0 Ventilation 10 Connector and Wiring details 11 AC Mains 11 Audio Connections 12 Analogue inputs 12 Amplifier outputs 12 Dante and Control Interface 13 ANS microphone input 13 Failure relay 14 DSP se...

Страница 4: ...receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused for long...

Страница 5: ...analogue inputs plus dual redundant Dante interface 8 x 100W output into 100 ohm load OVERVIEW The AXYS IndustryAmp is a multichannel power amplifier specifically designed for permanent installation i...

Страница 6: ...ge protocol by using the Dante Ethernet interfaces Pilot tone detection ANS Ambient Noise Sensing mic input Surveillance failure relay DSP bypass function Universal power supply 100 240 VAC with activ...

Страница 7: ...mers Load Monitoring Surge Protection Input 1 Out 1 Out 2 Out 3 Out 4 Input 2 Internal Temperature Fan Monitoring Front LED Internal Supplies Mains External Failure Relay Analogue Pilot detect Digital...

Страница 8: ...ut connections may be made The detector will when enabled switch from Input 1 to Input 2 if pilot tone is lost The IndustryAmp incorporates surveillance functions which activate an externally accessib...

Страница 9: ...2 13 14 Wiring details for all the rear connectors can be found in subsequent sections of the manual Not present on PB 400 DN 2 Failure relay connector 3 ANS microphone input 4 Analogue input 1 5 Anal...

Страница 10: ...ontaining a significant quantity of other heat generating equipment see below consideration should be given to climate controlling the room in which the equipment rack is situated Do not install the I...

Страница 11: ...gate why it blew Always replace by a fuse of the same type and rating as indicated on the rear panel and or in the amplifier datasheet NOTE The PowerCon connector should NEVER be plugged in or unplugg...

Страница 12: ...IndustryAmp should always be used wherever possible If driving from an unbalanced source use the same wiring as shown above at the amplifier end but connect the hot core to the signal output and the...

Страница 13: ...increase the distance further A third party Ethernet to fibre interface will be required in these situations The Dante interfaces add digital audio I O and a control method to the IndustryAmp They pr...

Страница 14: ...oving an internal PCB jumper See fig 5 Failure relay In volt free operation CO is connected to NC a failure condition causes CO to be connected to NO When configured for impedance sensing use the impe...

Страница 15: ...Dante xmt 12 Dante xmt 13 Dante xmt 14 Dante xmt 15 Dante xmt 16 Dante xmt 17 Dante xmt 1 Dante xmt 2 Dante xmt 3 Dante xmt 4 Dante xmt 5 Dante xmt 6 Dante xmt 7 Dante xmt 8 To Dante Outputs Dante xmt...

Страница 16: ...han one input is selected to go to the same output then the inputs are summed Autogain The DSP section includes an autogain algorithm which can be set to automatically adjust the overall volume level...

Страница 17: ...to 23 5 kHz and the threshold may be set between 10 dBFS and 60 dBFS The amplifier s action on non detection of a pilot tone can be configured via WinControl A fault condition can be flagged and or th...

Страница 18: ...brated with the normal loads connected to each amplifier channel to establish a reference load current After calibration any partial or total failure of any of the loads or cabling will be registered...

Страница 19: ...of the chassis to ground Always connect this terminal 2 Reduction of RF emission Although the IndustryAmp electronics are well shielded and external connections are decoupled to prevent RF emission fr...

Страница 20: ...www axystunnel com...

Отзывы: