MXA-MP Specifications (Cont.)
VIDEO
• Video Preview Image Format: JPEG (accessed over HTTP)
• Max Number of Video Preview Images: 10
• Min Refresh Time of Preview Images: 2 sec per preview image
• Video Input: HDMI, DVI, RGBHV, S-Video, composite or component video
• Video Input Resolutions:
HDMI: 640x480p@60Hz, 800x600p@60Hz, 1024x768p@60Hz, 1280x720p@60Hz
DVI: 640x480p@60Hz, 800x600p@60Hz, 1024x768p@60Hz, 1280x720p@60Hz
RGB/GRAPHICS: 640x480p@60Hz, 800x600p@60Hz, 1024x768p@60Hz, 1280x768p@60Hz
COMPONENT: 720x480i@60Hz, 720x480p@60Hz, 720x576i@50Hz, 720x576p@50Hz
SVIDEO: ntsc, pal-bghid, pal-m
COMPOSITE: ntsc, pal-bghid, pal-m
NOTE: Although the frame rate to the panel does not apply on the MP, it still needs to be present in the
send command or the command setting the ‘videomode’ will not parse correctly. The send commands use
the @30 and @25 to specify the effective streaming frame rate instead of the @60 and @50 which refer
to the input source’s frame rate.
COMMUNICATIONS
Ethernet: 10/100 port, RJ-45 connector with Ethernet/IP pass-through
FRONT PANEL COMPONENTS • Power: (1) LED (green) lights when device is receiving power
• Status: (1) LED toggles on/off green every 5 seconds if communicating to the panel (i.e. the panel is
configured to use the MXA-MP)
• Video Input: (1) LED (red) lights when receiving video signals
• LAN: (1) LED (green) lights when the LAN connection is enabled
• Panel: (1) LED (green) lights when device is connected to the panel
• Reset Button: Reboots the unit when pressed
• Factory Reset Button: Resets the unit to factory defaults when pressed for at least 5 seconds
REAR PANEL COMPONENTS
• DVI-I: DVI-I multi-format video input
• HDMI: HDMI preview video output
• Analog Audio Jack: 1/8th-inch mini-jack input (not used)
• Power Output: 2-pin 3.5 mm Phoenix-style connector output, 12 Volts, 3 Amps
• Ethernet In: (1) 10/100 port, RJ-45 connector for connection to network
• Ethernet Out: (1) 10/100 port, RJ-45 connector for connection to touch panel
• Power: IEC power cord connector
ENVIRONMENTAL
• Temperature (Operating): 32° F to 104° F (0° C to 40° C)
• Temperature (Storage): 4° F to 140° F (-20° C to 60° C)
• Humidity (Operating): 20% to 85% RH
• Humidity (Storage): 5% to 85% RH
• Power ("Heat") Dissipation without Panel: 68 BTU/hr
• Power ("Heat") Dissipation with Panel: 170 BTU/hr
REGULATORY COMPLIANCE
• FCC Part 15 Class A
• CE EN 55022
• CE EN 55024
• CE EN 60065
• IEC 60065
• IC
• UL 60065
• RoHS
• WEEE
INCLUDED ACCESSORIES
• MXA-MP Installation Guide (93-5968-20)
• MIC AC Universal Power Cord (CA1090-131)
OPTIONAL ACCESSORIES
• MPA-VRK, Rack Shelf 1RU 7.3" Depth (FG5968-30)
• AC-SMB, Surface Mount Bracket Accessory (FG525)
• CC-3.5ST5-RCA2F, 5-pin 3.5mm Phoenix-style to 2 RCA Female Cable (FG10-003-20)