Harman®  •  Accentra Owner’s Manual_R40  •  2002 -___  •  11/15

21

3-90-08326c

Reference Material 

 

A. Safety Reminders

When  operating  your  Harman® Accentra  Pellet  Stove, 

respect  basic  safety  standards.  Read  these  instructions 

carefully before you attempt to operate the Accentra Pellet 

Stove. Failure to do so may result in damage to property or 

personal injury and may void the product warranty.

CAUTION: This appliance must be vented to the outside.

Due to high temperatures, this stove should be placed out 

of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high 

surface temperatures and should stay away  to avoid burn 

to skin and/or clothing.
Young children should be carefully supervised when they 

are in  the same room as the stove.
Clothing and other flammable materials should not be placed 

on or near this stove.
Installation  and  repair  of  this  stove  should  be  done  by  a 

qualified service person. The appliance should be inspected 

before use and at least annually by a qualified service person. 

More  frequent  cleaning  will  be  required.  It  is  imperative 

that  control  compartments,  burners,  and  circulating  air 

passageways of this stove be kept clean.

Disposal of ashes

: Ashes  should  be  placed  in  a  metal 

container  with  a  tight  fitting  lid. The  closed  container  of 

ashes should be placed on a non-combustible floor or on the 

ground, well away from all combustible materials, pending 

final disposal. If the ashes are disposed of by burial in soil 

or otherwise locally dispersed, they should be retained in 

the closed container until all cinders have thoroughly cooled.

Soot and fly ash: 

Formation and need for removal. The 

products of combustion contain small particles of fly ash. 

The fly ash will collect in the exhaust venting system and will 

restrict the flow of the flue gases. Pellet fuels have different 

ash contents depending on what type of wood has been used 

to make the pellets. 

We recommend to clean the system 

after approximately 1 ton of pellets have been burned 

and judge from that how often the stove should be 

cleaned, remember if you change pellets it may change 

how often you have to clean your stove. 

When burning wood slowly, the potential exists for creosote 

to form. The venting system should be inspected periodically 

throughout the heating season to determine if a creosote 

buildup  has  occurred.  If  a  significant  layer  of  creosote 

has accumulated (3mm or more), it should be removed to 

reduce the risk of a chimney fire. If a fire occurs, call the 

fire  department,  shut  down  the  stove,  and  evacuate  the 

residence.  Before  using  the  appliance,  have  the  venting 

system  thoroughly  inspected  and  replace  any  damaged 

components.

USE OF IMPROPER FUELS, FIRE STARTERS OR 

ALTERING THE STOVE FOR HIGHER HEAT OUTPUT 

MAY CAUSE DAMAGE TO THE STOVE AND COULD 

RESULT IN A HOUSE FIRE. USE ONLY APPROVED 

FUELS AND OPERATION GUIDELINES

WARNING

!

KEEP COMBUSTIBLE MATERIALS SUCH AS GRASS, 

LEAVES, ETC. AT LEAST 3 FEET AWAY FROM THE 

POINT DIRECTLY UNDER THE VENT TERMINATION.

WARNING

!

THE STOVE IS HOT WHILE IN OPERATION.
KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.  

CONTACT MAY CAUSE SKIN BURNS.

CAUTION

!

THE STRUCTURAL INTEGRITY OF THE MOBILE 

HOME FLOOR, WALL, AND CEILING/ROOF MUST BE 

MAINTAINED.

CAUTION

!

MOBILE/MANUFACTURED HOME GUIDELINES DO 

NOT ALLOW INSTALLATION IN A SLEEPING ROOM.

WARNING

!

With any hearth appliance, installation of smoke detectors 

is recommended on every level of the home. 

Possible causes of smoke detector activation:

Paint curing process - Open a window near the appliance 

for the first few hours of burning.
Exhaust being drawn back inside the dwelling - Outside air 

connection to the appliance is necessary.
Vent leakage - All interior seams and joints should be sealed 

with silicone where applicable. Follow vent manufacturers 

instructions for proper sealing.

Содержание Accentra

Страница 1: ...g codes prior to installation Installation MUST comply with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspection requirements in your area Tested and approved for wood pellet fuel only Burning of any other type of fuel voids your warranty Hot glass will cause burns Do not touch glass until it is cooled NEVER...

Страница 2: ...ctions du fabricant Ce poêle à bois doit inspection périodique et la réparation pour un fonctionnement correct Consultez le manuel du propriétaire pour plus d informations Ce est contre les règlements fédéraux pour faire fonctionner cepoêleàboisd unemanièreincompatibleaveclesinstructionsd utilisation dans le manuel du propriétaire Contactez le service des incendies à propos des restrictions et l i...

Страница 3: ...neral Maintenance 14 D Glass Maintenance 15 E Burnpot Maintenance 16 F Heat Exchanger Combustion Blower Maintenance 17 G Pellet Feeder Chamber 18 Safety Alert Key DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situati...

Страница 4: ...a mobile home installation NOTE This installation must conform with local codes In the absence of local codes you must comply with the ASTM E1509 2004 ULC S628 93 ULC ORD C 1482 M1990 UM 84 HUD THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED DO NOT INSTALL IN SLEEPING ROOM WARNING The Accentra is Certified to comply with 2015 particulate emission st...

Страница 5: ... inconsistent with operating instructions in this manual Harman is a registered trademark of Hearth Home Technologies WARNING Risk of Fire Hearth Home Technologies disclaims any responsibility for and the warranty and agency listing will be voided by the below actions DO NOT Install or operate damaged appliance Modify appliance Install other than as instructed by Hearth Home Technologies Operate t...

Страница 6: ...se burns DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as stove Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away 3 General Information WARNING B Clear Space WARNING R...

Страница 7: ...s the stove temp goes up so does the L and H scale Power Light Indicates power to the control Indicates power to the feed motor Indicates power to combustion blower Status Light Will be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down Blinks to indicate errors listed below Indicates power to distribution blower Indicates igniter is on...

Страница 8: ...maintenance procedures D Fuel Specifications Fuel and Fuel Storage Pellet fuel quality can fluctuate from manufacturer to manufacturer and even from bag to bag Hearth Home Technologies recommends using only fuel that is certified by the Pellet Fuels Institute PFI Fuel Material Made from sawdust and or other wood by products Source material typically determines ash content Higher Ash Content Materi...

Страница 9: ...appliance will always start up on High After burning approximately 7 10 minutes the appliance will then burn at the rate at which it was originally set If the appliance is set at one of the lower settings it will run quieter but take longer to heat up an area than if it were set at a higher burn rate Regardless of the burn rate when the area is warm enough to satisfy the room sensor the appliance ...

Страница 10: ... through a quick diagnostics test to insure the control is operating properly This is normal 3 For your first fire it may be necessary to purge the auger system by putting the feed Limit knob to Test prior to starting the unit Figure 4 3 This insures that plenty of fuel enters the burn pot for proper ignition 4 Flip toggle switch to desired mode auto or Disabled Figure 4 4 Set Feed Limit knob to d...

Страница 11: ... In room temp mode however the blower will turn on and off in accordance to what temperature the room sensor is reading When the room sensor is satisfied the blower will shut down until the room sensor sees a demand for heat 3 Occasionally the appliance may run out of fuel and shut itself down When this happens the unit will need to be turned to the off position and restarted If needed follow Sect...

Страница 12: ...perate if the view door is open 4 Adjust Feed Rate If this is your first fire or you are trying different pellets set the Feed Limit to 4 Figure 4 6 This is a conservative number and will probably need to be increased After you know a feed rate setting that works well use that setting Remember if your feed rate is too high you may waste fuel 5 This is usually a weekly maintenance procedure Cleanin...

Страница 13: ...tant fuel consumption rate is sacrificed for exact room temperature Therefore as it gets colder more pellets will be burned automatically The distribution blower speed will vary according to the position of the mode selector pointer and fire size Igniter switch to AUTO Constant Burn Mode This allows for automatic ignition upon start up only The unit can then be set at any desired setting The heat ...

Страница 14: ... burnpot If the fuel you are burning has a high dirt or ash content it may be necessary to clean the burnpot more than once a day Dirty fuel will cause clinkers to form in the burnpot A clinker is formed when dirt ash or a non burnable substance is heated to 2000 F 1093 C and becomes glass like Enamel Touch Up Enamel touch up paint is provided for fixing minor enamel chips or blemishes that may oc...

Страница 15: ... acidity of the ash Never clean the glass while it is hot and do not use abrasive substances Wash the surface with cool water and rinse thoroughly You may wish to use a non abrasive cleaner specifically designed for use on stove glass In any case dry thoroughly before relighting your stove Glass Replacement If the stove s glass is cracked or broken you must replace it before operating your stove R...

Страница 16: ...burn pot This will help knock pieces of ash loosened by the scraping process down through the holes It also helps knock scale off of the igniter element Figure 5 3 The igniter is made to be removable for service by insulated male female wire connectors These connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the ...

Страница 17: ...peat the process with the second heat exchanger cover Figure 5 4 Heat Exchanger cover latch Figure 5 5 The units interior is now ready to clean Use the scraper provided to clean the heat exchanger surfaces A wire brush or short bristled brush is an excellent cleaning tool Clean the fan blade and combustion blower fan housing NOTE Be careful not to bend the fan blade while cleaning Abent blade will...

Страница 18: ...ain it is centered on the feeder body and tighten the wing nuts as tightly as you can by hand NOTE Views are shown with the rear motor covers removed Figure 5 8 G Pellet Feeder Chamber Figure 5 7 With the blower housing open there is easy access to the flue pipe exiting the rear of the unit Figure 5 7 Vacuum the flue pipe as far into the pipe as possible NOTE Be careful while cleaning the flue pip...

Страница 19: ...ode Description B Frequently Asked Questions ISSUES SOLUTIONS 1 Metallic noise 1 Noise is caused by metal expanding and contracting as it heats up and cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of your appliance 2 White ash buildup on glass 2 This is normal Clean the glass using any non abrasive glass cleaner 3 Glass ...

Страница 20: ...ck for status light 1 No fuel in hopper 2 Draft is too low blocked flue 3 Something is restricting fuel flow 4 Hopper lid not closed properly 5 Feed motor or combustion blower has failed SMOKE IS VISIBLE COMING OUT OF VENT 1 Air fuel ratio is too rich a Feed rate too high b Draft too low caused by a gasket leak LOW HEAT OUTPUT 1 Feed rate too low 2 Draft too low because of gasket leak 3 Poor quali...

Страница 21: ... of the flue gases Pellet fuels have different ash contents depending on what type of wood has been used to make the pellets We recommend to clean the system after approximately 1 ton of pellets have been burned and judge from that how often the stove should be cleaned remember if you change pellets it may change how often you have to clean your stove When burning wood slowly the potential exists ...

Страница 22: ...P combination is responsible for all high limit safety control There are 2 high limits one normal operation high limit and one backup high limit The control has an automatic diagnostic circuit that continuously monitors the ESP and Room Sensor for faults If a fault should occur the control sends a status alert and at the same time the unit goes down to minimum feed minimum burn as a safety conditi...

Страница 23: ...l remain shut down If the fire is out and the ESP is still warm the feeder may restart Since the fire is out the ESP temperature will not rise The unit will then shut down and may flash a six blink status error See ESP error codes If the fire is still burning it will resume normal operation Contact your dealer if you have questions about UPS compatibility with your appliance Use only Harman approv...

Страница 24: ...0001 1 10 247213A 008400001 008408015 1 10 247778A Post 008408015 1 10 247260A Y Gasket Hopper Throat 3 44 677185 Y Gasket Hopper Top 1 00 375501 Y Grommet 3 4 3 31 960021 Hopper Switch 48 Post 008403501 3 20 232108 Y Additional service parts on following page 10 15 1 90 02470 2 Charcoal Ending Manufacturing Date June 2011 1 90 02470 3 Golden re Ending Manufacturing Date June 2011 1 90 02470 4 Met...

Страница 25: ...95L Hopper Ball Spring Plunger Threaded Pkg of 3 3 31 5500 3 Hopper Lid Ball Spring Mount Bracket Pre 11340 2 00 247116 Hopper Lid Glass Assembly w Gasket Pre 11340 1 10 247100 Y Hopper Hinge Assembly Qty 2 req Pre 11340 1 10 247151 Y Hopper Lid Hinge Post 11340 2 00 06694 Hopper Lid Spring Latch Pre 11340 1 00 247167 Hopper Lid Latch Set OF 2 Post 11340 1 00 0669697 Y Push Retainer 5 16 Pkg of 10...

Страница 26: ...00 00247 Y 22 Cast Door w Rope and Grill 1 10 247109A Door Rope 1 00 00888 Y 23 Cast Air Grill 3 00 247114 24 Door Glass with Gasket 1 00 777000 Y Glass Rope 1 00 2312 Y 25 Glass Retainer Qty 2 req 2 00 247156B 26 Cast Front Frame 4 00 247108C 27 Ash Pan Weldment 1 10 247160 Y 28 Accordion Cover Latch w Hardware 1 00 247131 29 Cast Base Plate Painted 4 00 247110D 30 Distribution Blower Plate 2 00 ...

Страница 27: ...nd Gasket 2 Sets 1 00 677152 Y 37 6 Gear Motor 4 RPM 3 20 08752 Y 37 7 Sprocket Kit 1 00 06626 Y 37 8 Bracket Gear Motor 1 10 677005 Y Grommets Spacers Pkg fo 25 1 00 960026 37 9 3 4 Feeder Tensioner 3 31 00075 Y 37 10 3 1 2 Sprocket w Hub 1 10 08550W Y 37 11 Chain 60 Pin 3 50 06667 Y 37 12 3 1 2 Sprocket 2 00 06626M Y 37 13 Cast Cam Block 3 00 00153 Y 37 14 Cam Bearing 3 31 3014 Y 37 15 Bearing F...

Страница 28: ... Air Intake Assembly 1 10 06810A 38 5 Gasket Feeder Air Intake Pkg of 6 3 44 72224 6 Y 38 6 UL Feeder Air Intake 1 10 247239 38 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 38 8 Ultra Feeder Weldment 1 10 724132 Y 38 9 UL Feeder Pusher Arm 1 10 677187W Y 38 10 Fines De ector No longer available 2 00 677138 10 38 11 Gasket UL Feeder Cover 1 00 677122 Y 38 12 Slide Plate Assembly 1 10 677121...

Страница 29: ... Guide Bracket 2 00 247435 Y Fuse 6 AMP Pkg of 5 3 20 49447 5 Y Gasket Base and Sides 5 Ft 1 00 37525 Y Gasket Burn Pot Tailpipe Pkg of 5 1 00 07381 Y Hopper Muf er Fittings 1 00 18186618 Y Hopper Switch Retro t Kit 1 00 232108 Y Inlet Reduction Ring Combustion Blower 1 00 247234 Labels Caution Danger 10 Ea 1 00 200408541 Label Large Caution 3 90 00247 Leg Levelers Pkg of 4 1 00 12302 Power Cord 8...

Страница 30: ...case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for part...

Страница 31: ...E WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sour...

Страница 32: ...________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ___________________________________________________________...

Отзывы: