When installing and operating your Harman Accentra
Pellet Stove, respect basic safety standards. Read
these instructions carefully before you attempt to install
or operate the Accentra. Failure to do so may result in
damage to property or personal injury and may void the
product warranty.
Several issues must be addressed when selecting a
suitable location for your Accentra Pellet Stove. Observing
required clearances to combustible materials, the proximity
to a safe chimney or venting system, and the accessibility
of electrical supply must all be considered.
Place the stove on a noncombustible floor surface or
floor protector. This can be a minimum of a 20 gauge
sheet metal plate, ceramic tile with grouted joints, a UL
listed stove board, or a Harman Cast Iron floor protector.
The Harman Cast Iron Floor Protector is equal to the minimum
dimensions
,
which are 24
1/16"
x 28
5/8"
.
This allows for a 2"
extension on each side of the unit (which is actually
6
inches from the window
opening) and a 6" extension
to the front (measured
from the window
opening also)
(3
3/8
" if measured from the base plate front edge.) The
rear edge of the floor protection can be flush with the cast
base plate rear edge.
NOTE for Canadian installation only:
Per
ULC-S627-00, If installed on a combustible floor, the
need to provide a noncombustible
floor protector
covering
the area beneath the
space heater
and extending at
least 17.72" (450mm) on the firing side and at least 7.87"
(200mm) on the other sides.
Floor protection is required under any horizontal venting.
This protection must extend 2 inches (5.8cm) beyond each
side of the horizontal pipe.
Place the stove away from combustible walls at least
as far as shown in figures 10, 11, & 13.
Clearances may Only be reduced using methods
Approved by the regulating Authority having
jurisdiction.
Note that the clearances shown are minimum for safety
but do not leave much room for access when cleaning or
service is needed.
Installation
CAuTION
hOT whIlE IN OPErATION.
KEEP ChIldrEN, ClOThINg ANd FurNITurE
AwAY. CONTACT mAY CAuSE SKIN burNS.
The Clearance to The Top of The Unit is 60" (152cm)
Measured From The Floor.
dO NOT CONNECT TO ANY AIr
dISTrIbuTION duCT Or SYSTEm.
INSTAll vENT AT ClEArANCES
SPECIFIEd bY ThE vENT mANuFACTurEr.
dO NOT uSE mAKEShIFT COmPONENTS
Or COmPrOmISES whEN INSTAllINg
ThIS APPlIANCE. YOur SAFETY IS A
SErIOuS CONCErN.
Fig.11
12"
305mm
2.25"
57mm
l
j
Floor Protection
requirements
US
Canada
Sides
Rear
6"
200mm
0"
200mm
K
Front
6"
450mm
j
j
K
l
uSA
CANAdA
NOTE:
Measurement
"K" is measured from
the glass in the US
ONLY
This is the minimum size Harman
recommends for an alcove with a 60" ceiling.
54"
2.25"
14.75"
14.75"
Fig. 13
24"
F
loor
protector
Harman Cast Iron
Floor Protector size:
24
1/16
(611mm) X
28
5/8
(727mm)
5” min. 5” min.
6.25"
159mm
6.25"
159mm
Содержание Accentra
Страница 2: ......
Страница 41: ...41 Service Maintenance Log Date Of Service Performed By Description Of Service ...
Страница 42: ...42 Service Maintenance Log Date Of Service Performed By Description Of Service ...
Страница 43: ......