background image

10

Wired Remote Control

If you wish to control your deck with an
external infrared remote control sensor,
connect the wire from the remote sensor to
your cassette deck’s “Remote Input” jack. 
(A control wire may then be run from the
deck’s “Remote Output” jack to the “Remote
Input” of another stereo component.)

Alternatively, if you have a stereo component
with a built-in infrared remote sensor and a
“Remote Output” jack, it may be possible to
connect this jack to the “Remote Input” jack
of your cassette deck. Not all components
are compatible, but it will not hurt to
experiment.

In addition, most Harman Kardon Receivers

include a System Remote Control which will
control the functions of the cassette deck.

Cleaning the Tape Heads

Tape heads must be cleaned periodically to
remove tape particles, which gradually build
up on the heads, impairing sound quality and
increasing wear on tapes. Heads may be
cleaned in either of two ways:

1. Slightly dampen a cotton swab in
isopropyl alcohol and gently rub the surfaces
of each tape head. Use a second dampened
swab to clean other surfaces coated with
tape material. Repeat this cleaning every 30
tapes. The TD470 is equipped with an
access hole on the top of the unit to facilitate
cleaning of the heads. Be careful not to lose
the cover to this access hole.

2. Use a tape head cleaning kit, which
comes in the form of a tape cassette, and is
simply inserted into the deck. Follow the
instructions included with the kit.

Demagnetization

Tape heads and other internal parts
gradually pick up magnetic fields, which can
add noise to your tapes and even partially
erase them. To prevent this problem, tape
heads should be periodically demagnetized.

A battery-powered demagnetizer is easiest
to use. It comes in the form of a tape
cassette and is simply inserted into the deck.
Be certain to use this demagnetizer as
frequently as its instructions recommend.

Care of Tape

1. Store cassettes in their cases, in a location
away from direct sunlight, excessive heat
and high humidity. 

2. Avoid placing a tape near a television set
or loudspeaker; their magnetic fields can
partially erase the tape.

3. To prevent accidental erasure of a tape,
use a small screwdriver to remove the two
square tabs located on the side of the
cassette opposite the exposed tape. With
these tabs removed, the tape cannot be
recorded. If you later wish to record an
erasure-protected tape, simply cover the
small holes with adhesive tape.

4. Do not use old cassettes whose tape no
longer moves smoothly from reel to reel.
They may jam and damage your deck.

ENGLISH

24505_TD470 eng  12/01/98 14:01  Side 10

Содержание TD470

Страница 1: ... of installation ____________________________________________________________ Serial No ______________________________________________________________________ 1 Unpacking and Installation Congratulations on Your Purchase Your new high fidelity TD470 is designed to deliver maximum enjoyment and years of trouble free service Please take a few moments to read this manual thoroughly It will explain th...

Страница 2: ... 10 do not attempt to service this unit Tampering with internal components can cause fire or shock and may void your guarantee If water or small objects enter the unit unplug the power cord immediately and consult an authorized Harman Kardon service center Using the unit under such conditions may cause a fire or shock hazard Cleaning Remove dust by wiping the unit with a soft dry cloth If necessar...

Страница 3: ...de and to monitor the input signal when the unit is in the recording mode The user can override the automatic setting by pressing the Tape Source button Wireless Remote Control This unit has a front panel IR remote sensor and an accessory remote control It is also compatible with the cassette deck commands included on system remote controls included with all Harman Kardon remote controlled receive...

Страница 4: ... 35 20 10 7 5 3 1 1 3 5 8 dB INTRO REC PLAY MPX TYPE I I IV Power Remote Senor Rec Mute Intro Scan Search S C MPX Filter Off Dolby NR B Counter Reset Bias Fine Trim Balance Record Level Open Close TD 470 16 1 20 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 27 28 29 ENGLISH 24505_TD470 eng 12 01 98 14 01 Side 4 ...

Страница 5: ...level 15 Open Close Press to load remove tape cassette 16 Cassette Compartment Drawer 17 Counter Reset Resets Tape Counter to 00 00 18 CD Sync Engage when synchronizing recording with a Harman Kardon CD Player 19 Tape Source Selects between the signal recorded on the tape and the input source signal When Tape is selected the indicator above the button will light 20 Remote IR Sensor Receives the re...

Страница 6: ...emote control The remote control is powered by two AA batteries included in the carton When the batteries weaken replace both of them at the same time If the remote control will be unused for a long period of time remove the batteries to prevent damage from corrosion L R BCS CD Sync Tape Source Bias Tone REC Cal L R 35 20 10 7 5 3 1 1 3 5 8 dB INTRO REC PLAY MPX TYPE I I IV Power Remote Senor Powe...

Страница 7: ...nter accuracy is typically within 1 minute of the tape s actual running time Recording a Tape 1 Set the Bias Fine Trim knob to the middle position or previously determined proper position for the tape refer to following section for details 2 Press the Dolby NR button to turn Dolby NR circuitry on off and press Dolby NR button to select Dolby B C or S NR as follows a To record a tape without Dolby ...

Страница 8: ...le the Bias Tone Button is held pressed as described in Step 6 of the Bias Fine Trim Setting Procedures 5 Release the Bias Tone Button and press and hold the Rec Cal Button again to make sure the levels are still calibrated to mark on both channels 6 It is advisable that you note the positions of these knobs for your future reference You can save time at your next recording using the same brand an...

Страница 9: ...onnected to the Tape Monitor loop of your receiver pre amp integrated amplifier you have two choices a Connect the deck to the Tape Monitor loop provided on the last outboard component or b If your receiver pre amp integrated amplifier has two Tape Monitor loops you may connect the cassette deck to the unused loop In this case the cassette deck will be unaffected by the external signal processing ...

Страница 10: ...the unit to facilitate cleaning of the heads Be careful not to lose the cover to this access hole 2 Use a tape head cleaning kit which comes in the form of a tape cassette and is simply inserted into the deck Follow the instructions included with the kit Demagnetization Tape heads and other internal parts gradually pick up magnetic fields which can add noise to your tapes and even partially erase ...

Страница 11: ...ted properly The hookup wires are unbroken The Tape Source switch is set to Tape indicator is on The cassette deck does not record The erase prevention tabs have not been removed from the tape cassette The Input Level knob is set high enough The tape deck is connected properly The hook up cables are unbroken When a tape you have recorded is played back the sound is distorted The Input Level was no...

Страница 12: ...e 90 sec C 60 Peak Reading Meter Range 35dB to 8dB Output Level 0dB 10k Ohm load 640mV Input Sensitivity 0dB Line 45mV Input Impedance Line 22k Ohms Dimensions w x h x d 442mm x 126mm x 320mm Weight 5 4 kg DECLARATION OF CONFORMITY We Harman Marketing Europe a s Kongevejen 194B DK 3460 Birkerød DENMARK declare that the product described in this owner s manual is in compliance with technical standa...

Отзывы: