Harman Kardon AVR 210 Скачать руководство пользователя страница 6

 

AVR100 

To correct this problem, first unplug the unit from the AC wall outlet and 
wait at least three minutes. After the pause, reconnect the AC power 
cord and check the unit’s operation. If the system still malfunctions, a 
system reset may clear the problem.  To clear the AVR 100’s entire 
system, first turn the unit off by pressing and releasing the 

Main Power 

Switch 

so that it pops out from its normal recessed position. Next, press 

and hold the 

CD 

and 

Vid 2

 buttons while pushing in the 

Main Power 

Switch 

to turn the unit back on. 

 

AVR110 

To correct this problem, first unplug the unit from the AC wall outlet and 
wait at least three minutes. After the pause, reconnect the AC power 
cord and check the unit’s operation. If the system still malfunctions, a 
system reset may clear the problem. To clear the AVR 110’s entire 
system, first put the unit in Standby by pressing the 

System Power 

Control 

button. Next, press and hold the 

Tone Mode 

and the 

FM Mode 

Selector 

buttons for three seconds. The unit will turn on automatically 

and display the 

RESET

 message in the 

Main Information Display

.

 

 

AVR120 

To correct this problem, first unplug the unit from the AC wall outlet and 
wait at least three minutes. After the pause, reconnect the AC power 
cord and check the unit’s operation. If the system still malfunctions, a 
system reset may clear the problem. To clear the AVR 120’s entire 
system, first put the unit in Standby by pressing the 

System Power 

Control 

button. Next, press and hold the 

Tone Mode 

and the 

FM Mode 

Selector 

buttons for three seconds. The unit will turn on automatically 

and display the 

RESET

 message in the Main Information Display 

 

AVR125 

To correct this problem, first unplug the unit from the AC wall outlet and 
wait at least three minutes. After the pause, reconnect the AC power 
cord and check the unit’s operation. If the system still malfunctions, a 
system “reset” may clear the problem. To clear the AVR 125’s entire 
system, first put the unit in Standby by pressing 

the System Power 

Control Button

.  Next, press and hold the 

Tone Mode

 button for 

three seconds. The unit will turn on automatically and display the 

RESET

 

message in the Main Information Display 

 

AVR130 

To correct this problem, first unplug the unit from the AC wall outlet and 
wait at least three minutes. After the pause, reconnect the AC power 
cord and check the unit’s operation. If the system still malfunctions, a 
system “reset” may clear the problem. To clear the AVR 130’s entire 
system memory , first put the unit in 

Standby by pressing the 

Standby/On Switch

 so that the Power Indicator turns amber. Next, 

press and hold the 

Tone Mode 

Button for three seconds. The unit will 

reset and then turn on automatically. 

 

AVR210 

To correct this problem, first unplug the unit from the AC wall outlet and 
wait at least three minutes. After the pause, reconnect the AC power 
cord and check the unit’s operation. If the system still malfunctions, a 
system reset may clear the problem. To clear the AVR 210’s entire 
system, first put the unit in Standby by pressing the 

System Power 

Control 

button. Next, press and hold the 

Tone Mode 

and the 

FM Mode 

Selector 

buttons for three seconds. The unit will turn on automatically 

and display the 

RESET

 message in the Main Information Display 

 

AVR220 

To correct this problem, first unplug the unit from the AC wall outlet and 
wait at least three minutes. After the pause, reconnect the AC power 
cord and check the unit’s operation. If the system still malfunctions, a 
system reset may clear the problem. To clear the AVR 220’s entire 
system, first put the unit in Standby by pressing the 

System Power 

Control 

button. Next, press and hold the 

Tone Mode 

and the 

FM Mode 

Selector 

buttons for three seconds. The unit will turn on automatically 

and display the 

RESET

 message in the Main Information Display 

 

AVR225 

To correct this problem, first unplug the unit from the AC wall outlet and 
wait at least three minutes. After the pause, reconnect the AC power 
cord and check the unit’s operation. If the system still malfunctions, a 
system “reset” may clear the problem. To clear the AVR 225’s entire 
system, first put the unit in Standby by pressing 

the System Power 

Control Button

.  Next, press and hold the 

Tone Mode

 button for 

three seconds. The unit will turn on automatically and display the 

RESET

 

message in the Main Information Display 

 

 
 

 

 

Содержание AVR 210

Страница 1: ...n be found near the last page or check the service website www harmanservice com for the latest info 2 Print the block diagram from the service manual 3 With no inputs or speakers attached to the AVR...

Страница 2: ...chart shows the analog signal flow from the input jacks to the output jacks 11 If the output levels are the same check the power out stage at the speaker out jacks 12 If you find the levels at the spe...

Страница 3: ...9 19 20 3 1 5 SW 7 8 10 10 9 5 7 11 AVR320 520 8 C H I N I C 5 0 1 I n I C 5 0 1 O u t C N 4 0 8 I C 7 0 4 I n I C 7 0 4 O u t I C 7 0 5 I n I C 7 0 5 O u t I C 7 0 6 I n I C 7 0 6 O u t I C 7 1 4 I n...

Страница 4: ...25 21 23 5 SUB 2 4 4 2 3 SBL 21 19 21 23 5 7 13 SBR 8 10 4 2 3 1 11 AVR230 330 6 c h i n I C 2 3 I n I C 2 3 O u t I C 2 6 I n I C 2 6 O u t I C 4 2 I n I C 4 2 O u t I C 4 I n I C 4 4 O u t I C 4 3 I...

Страница 5: ...sing the Master Power Switch so that it pops out from its normal recessed position Next press and hold the AM FM and the Dolby Pro Logic buttons while pushing the Master Power Switch in to turn the un...

Страница 6: ...seconds The unit will turn on automatically and display the RESET message in the Main Information Display AVR130 To correct this problem first unplug the unit from the AC wall outlet and wait at leas...

Страница 7: ...l turn on automatically and display the RESET message in the Main Information Display AVR325 To correct this problem first unplug the unit from the AC wall outlet and wait at least three minutes After...

Страница 8: ...power cord and check the unit s operation If the system still malfunctions a system reset may clear the problem To clear the AVR 430 s entire system memory first put the unit in Standby by pressing th...

Страница 9: ...t s operation Clear the program by pressing the OPEN CLOSE button or the STOP CLEAR button over 4 seconds FL8400 To correct this problem first unplug the unit from the AC wall outlet and wait at least...

Страница 10: ...beyond the front panel and the word OFF is visible in red lettering at the top of the switch Next press and hold the T Mon and CD Input Selector buttons on the front panel ONLY While holding these but...

Страница 11: ...and wait at least three minutes After the pause reconnect the AC power cord and check the unit s operation If the system still malfunctions a system reset may clear the problem To clear the DCR600 s...

Отзывы: