background image

 

harman/kardon

        

TECH TIPS

 

 

Troubleshooting tips and solutions to common service problems 

 

TIP# HKTT2004-03        

 

 

 

 

 

 

 

Isolating audio problems in an AVR receiver 

Using 6/8 Direct In 

 

 
The following charts are used to help the tech quickly isolate 
audio problems in an AVR receiver. Use the following 
procedures to help find what is working, then to quickly locate 
the problem area. 

 

Equipment needed: 

 

9

  1 set of (RCA) Y adaptors. 

9

 Function/signal generator. 

9

 Oscilloscope. 

 

Models covered: 

AVR210 AVR310
AVR220 AVR320
AVR520 AVR225
AVR125 AVR525
AVR130 AVR230
AVR330 AVR430
AVR630  

Procedure: 

 

1) 

Do a factory reset of the receiver. (This will eliminate any common micro processor 

problems.) Reset List can be found near the last page or check the service 
website; www.harmanservice.com for the latest info. 

 

2) 

Print the block diagram from the service manual. 

 

3) 

With no inputs or speakers attached to the AVR turn on the receiver and turn the 

volume all the way down. 

 

4) 

Turn unit off. 

 

5) 

Hook up an oscillator to the 6/8 Direct in jacks using the Y adaptors. Adjust the 

oscillator to about 0db (.775Volts RMS). 

 

6) 

Hook up an oscilloscope to monitor the line out jacks. Or, if there are no line out 

(preamp out) jacks monitor the input to the power amps or the speaker outs. 
(AVR125, 225, 130 do not have preamp out jacks) 

 

7) 

Turn the AVR on. Select 6 or 8 direct in, depending on the receiver. 

 

8) 

Slowly turn the volume control up until you can easily measure the voltage at the line 

out jacks. ( -40 to -25db ) 

Harman Consumer Group  250 Crossways Park Dr. Woodbury, New York 11797 

Email [email protected] 

Содержание AVR 210

Страница 1: ...n be found near the last page or check the service website www harmanservice com for the latest info 2 Print the block diagram from the service manual 3 With no inputs or speakers attached to the AVR...

Страница 2: ...chart shows the analog signal flow from the input jacks to the output jacks 11 If the output levels are the same check the power out stage at the speaker out jacks 12 If you find the levels at the spe...

Страница 3: ...9 19 20 3 1 5 SW 7 8 10 10 9 5 7 11 AVR320 520 8 C H I N I C 5 0 1 I n I C 5 0 1 O u t C N 4 0 8 I C 7 0 4 I n I C 7 0 4 O u t I C 7 0 5 I n I C 7 0 5 O u t I C 7 0 6 I n I C 7 0 6 O u t I C 7 1 4 I n...

Страница 4: ...25 21 23 5 SUB 2 4 4 2 3 SBL 21 19 21 23 5 7 13 SBR 8 10 4 2 3 1 11 AVR230 330 6 c h i n I C 2 3 I n I C 2 3 O u t I C 2 6 I n I C 2 6 O u t I C 4 2 I n I C 4 2 O u t I C 4 I n I C 4 4 O u t I C 4 3 I...

Страница 5: ...sing the Master Power Switch so that it pops out from its normal recessed position Next press and hold the AM FM and the Dolby Pro Logic buttons while pushing the Master Power Switch in to turn the un...

Страница 6: ...seconds The unit will turn on automatically and display the RESET message in the Main Information Display AVR130 To correct this problem first unplug the unit from the AC wall outlet and wait at leas...

Страница 7: ...l turn on automatically and display the RESET message in the Main Information Display AVR325 To correct this problem first unplug the unit from the AC wall outlet and wait at least three minutes After...

Страница 8: ...power cord and check the unit s operation If the system still malfunctions a system reset may clear the problem To clear the AVR 430 s entire system memory first put the unit in Standby by pressing th...

Страница 9: ...t s operation Clear the program by pressing the OPEN CLOSE button or the STOP CLEAR button over 4 seconds FL8400 To correct this problem first unplug the unit from the AC wall outlet and wait at least...

Страница 10: ...beyond the front panel and the word OFF is visible in red lettering at the top of the switch Next press and hold the T Mon and CD Input Selector buttons on the front panel ONLY While holding these but...

Страница 11: ...and wait at least three minutes After the pause reconnect the AC power cord and check the unit s operation If the system still malfunctions a system reset may clear the problem To clear the DCR600 s...

Отзывы: