Harman Home Heating PC 45 Скачать руководство пользователя страница 25

25

PC 45 Corn/Pellet Stove

Fuel Specification details

Fuel and Fuel Storage

Pellet fuel quality can fluctuate from manufacturer to 

manufacturer, and even from bag to bag. 

Hearth & Home Technologies recommends using only 

fuel that is certified by the Pellet Fuels Institute (PFI).
Fuel Material

•  Made from sawdust and/or other wood by-products

•  Shelled field corn

•  Source material typically determines ash content
Higher Ash Content Material

•  Hardwoods with high mineral content

•  Bark and leaves as source material

•  "Standard" grade pellets, corn and other biomass
Lower Ash Content Material

•  Softwood; pine, fir, etc.

•  Materials with lower mineral content

•  "Premium" grade pellets
Shelled field corn other grains

•  Must be 15% moisture content or less

•  Must be clean and free of debris

•  Stalk parts, excessive fines and cob remnants may 

cause feed system jams or blockage

CAUTION! Do not burn fuel that contains an addi-

tive; (such as soybean oil) 

•  May cause hopper fire

•  Damage to product may result

Read the list of ingredients on the packaging. If you are 

buying field corn, the only ingredient listed should be 

field corn.

WARNING! Risk of Chemical Poisoning!

Do 

NOT

 burn treated seed corn

•  Chemical pesticides are harmful or fatal if swallowed

•  Burning treated seed corn will void the product war-

ranty

Clinkers

Minerals and other non-combustible materials, like sand, 

will turn into a hard glass-like substance when heated. 

Trees from different areas will vary in mineral content. 

For this reason, some fuels will produce more clinkers 

than others.
Moisture

Always burn dry fuel. Burning fuel with high moisture 

content takes energy to dry and tends to cool the appli-

ance thus, robbing heat from your home. Damp pellet 

fuel could turn back into sawdust which does not flow 

properly through the feed system.

Size

•  Pellets are either 1/4 inch or 5/16 inch (6-8mm) in 

diameter

•  Length should be no more than 1-1/2 inches 

(38mm)

•  Pellet length can vary from lot to lot from the 

same manufacturer 

Performance

•  Higher ash content requires more frequent main-

tenance.

•  "Premium" grade pellets will produce the highest 

heat output.

•  Burning pellets longer than 1-1/2 inches (38mm) 

can cause inconsistent feeding and/or ignition.

We recommend that you buy fuel in multi-ton lots 

whenever possible. However, we do recommend try-

ing different brands prior to purchasing multi-ton lots, 

to ensure your satisfaction.

CAUTION! Tested and approved for use with wood 

pellets, shelled field corn, and grains such as wheat, 

barley, and oats ONLY. Burning of any other fuel will 

void your warranty.

When changing between fuels, the FEED ADJUSTER 

will likely need adjusted. When under maximum de-

mand, ensure there is no unburned fuel being pushed 

into the ash pan.
Storage

•  Wood pellets should be left in their original sealed 

bag until ready to use, to prevent moisture.

•  Shelled corn and grains should be stored in a 

tightly sealed container to prevent moisture and to 

deter pests

•  Do not store fuel within the specified clearance ar-

eas, or in a location that will interfere with routine 

cleaning and maintenance procedures.

CAuTION

Tested and approved for use with wood pellets 

and biomass fuels ONLY. Burning of any other fuel 

will void your warranty.

Hearth & Home Technologies is not responsible for 

stove performance or extra maintenance required 

as a result of using fuel with higher ash or mineral 

content.

NOTICE

Содержание PC 45

Страница 1: ...FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as m...

Страница 2: ......

Страница 3: ...ELACONSTRUC TION OU LE BUREAU DES POMPIERS AU SUJET DES RESTRICTIONS ET DES INSPECTIONS D INSTALLATION DANS VOTRE VOISINAGE EXEMPTION EPA PAR 40 CFR 60 534 DE M THODE 28a APPROUV POUR L USAGE DANS LES...

Страница 4: ...e ment during shipping To free the stove from the skid you must remove the hold down bolts in the rear of the pedestal base Removing or Installing rear panels To remove the rear cover panels loosen th...

Страница 5: ...efore use and at least annually by a qualified service person More frequent cleaning will be required It is imperative that control compartments burners and circulating air passageways of the stove be...

Страница 6: ...12 H A vent must not be installed within 3 feet 90 cm above a gas meter regulator assembly when measured from the horizontal center line of the regulator 1 I The clearance to service regulator vent o...

Страница 7: ...to burn corn or other grains be sure venting system is approved and warranted for corn burning The sections of pipe lock together to form an air tight seal however in some cases a perfect seal is not...

Страница 8: ...deration must be given to the total house demand House demand may consume the air needed for the stove It may be neces sary to add additional ventillation to the space in which the appliance is locate...

Страница 9: ...ral draft in the event of a power failure 2 Preferred method This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall The vertical...

Страница 10: ...venting for normal operation This method also provides natural draft in the event of a power failure The damper area must be sealed with a steel plate Kaowool mineral wool or an equivalent non combus...

Страница 11: ...sure to use approved pellet vent pipe fittings Seal pipe joints with silicone in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 6 Installi...

Страница 12: ...the ceiling vent follow PL vent manufacturers recommendations when using wall and ceiling pass through DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT...

Страница 13: ...low the grain cap to rest onto the burnpot sides Grain Cap Burn Pot Fig 18 Burn Pot with Smaller Holes The PC45 stove is built with a burn pot that has 125 1 8 combustion air holes This grate has no i...

Страница 14: ...board switches The pellet kit contains the instructions for the conversion a new burn pot end gate and a new combustion blower inlet ring This figure shows the corn burn pot as installed from the fac...

Страница 15: ...n the yellow range with a 3 setting being the maximum setting 1 the lowest setting This setting will vary depending on the quality of corn used When burning pellets the feed rate setting can be adjust...

Страница 16: ...he feed adjuster to TEST until the fuel is visible in the auger tube opening This also allows you to check the motors for operation NOTE The auger motor will not operate with the view door or ash door...

Страница 17: ...om Tempera ture Mode and Manual Room Temperature Mode is that the fire will not go out as the room temperature goes above the control board setting The unit can only go to low burn and will remain the...

Страница 18: ...ned Burning Corn 1 Turn the Feed Adjuster to the desired feed rate approximately 2 2 Turn the Mode Selector to OFF and then to the desired mode This will reset the control and start the combustion mot...

Страница 19: ...elow Indicates power to distribution blower 6 Blinks Indicates that the control has calculated poor or incomplete combustion occurring for more than 50 minutes See Troubleshooting section for more de...

Страница 20: ...rd the results for future reference Combustion Motor Speed Control Low draft only set point The small straight screwdriver slot is plastic therefore the unit can be adjusted while in operation Fig 27...

Страница 21: ...away from all combustible materials pending final disposal If ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders...

Страница 22: ...the fuel being used Fig 36 For further details see exploded view on page 22 Cleaning continued 5 Remove the ash pan 6 Remove the combustion blower cover by turning the blower cover latch vertical as...

Страница 23: ...n cool the parts can just be left exposed for several days and the slag buildup will crumble off of the parts 2 To accelerate this process the parts can be soaked in water for approximately 30 minutes...

Страница 24: ...ate too high B Draft too low caused by a gasket leak 2 Unit is in an ignition cycle LOW HEAT OUTPUT 1 Feed rate too low 2 Temperature setting too low Stove Temp Mode 3 Draft too low because of gasket...

Страница 25: ...moisture content takes energy to dry and tends to cool the appli ance thus robbing heat from your home Damp pellet fuel could turn back into sawdust which does not flow properly through the feed syst...

Страница 26: ...ove Weight 249 lbs Blower 135 cfm Feed Rate 0 to 5 0 lbs per hr Hopper Capacity 80 lbs Fuel Corn Wood Pellets Flue Size 3 inch Outside Air Size 2 3 8 I D Fuse Rating 6 amp 32 375 9 23 5 34 5 5 250 12...

Страница 27: ...e plating and therefore should never be used If the plating needs to be cleaned wait until the stove is completely cool then use a sponge soap and water to gently remove dirt and stains Before relight...

Страница 28: ...re than 25 feet from the unit or in another room are not recommended It is recommended that the room sensor be in stalled even if only installed on the rear of the unit as a return air sensor Room Sen...

Страница 29: ...S GROUND 18 3 RUBBER CORD N O WHITE BLUE GREEN WHITE GREEN RED ESP PROBE 6 AMP GLASS FUSE PART NO 3 89 02676D BLUE 120 VOLTS A C 60 HZ FEEDER AUGER MOTOR PUMP BLACK RED REMOTE SENSOR PORTS IGNITER ELE...

Страница 30: ...truction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlie...

Страница 31: ...t of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enamel...

Страница 32: ...let Part number list on following page 1 90 06800 1 black 1 90 06800 2 Charcoal 1 90 06800 3 goldenfire 1 90 06800 4 metallic blue 1 90 06800 5 honey glo 1 90 06800 10 mojave red 1 90 06800 12 Forest...

Страница 33: ...8055950 1 10 09685A Y 2 Feeder Assembly Pre 008055950 1 10 724129A 2 1 Air Intake Damper 1 10 06466W 2 2 Air Intake Weldment 1 10 06461 2 3 Feeder Weldment 1 10 724128 2 4 Slide Plate Assembly 1 10 08...

Страница 34: ...677122 Y 3 4 9MM Silicone Tube 5 FT 1 00 511427 Y 3 5 UL Feeder Auger Assembly 3 50 00665 Y 3 6 Bearing Flange w Hardware 1 00 04035 Y 3 7 UL Cast Cam Block 3 00 677154 Y 3 8 UL Motor Mount W Grommet...

Страница 35: ...olt on Hinge Weldment 2 00 06952B 17 Cast Door Frame 4 00 06800P 18 Glass Panel 3 40 950133125 Y 19 Door Handle Assembly Pre 1529 1 00 08704 Y Post 1529 1 00 453001 Y Wooden Handle w Hardware Load Doo...

Страница 36: ...135 Y Arrow Burn Pot Scraper Pkg of 10 2 00 773850 10 Fan Blade 5 Single Paddle Combustion Blower 3 20 40985 Y Fuse 6 Amp Pkg of 5 3 20 49447 5 Y Gasket 1 4 Rope Black W PSA Per Inch Glass 15 Ft 1 00...

Страница 37: ...It is not intended for continued operation Your appliance will recognize when power is restored What happens depends on ESP temperature and whether it is equipped with automatic ignition In Automatic...

Страница 38: ...38 pC 45 Corn pellet Stove Service Maintenance Log Date Of Service Performed By Description Of Service...