10 PC 45 Corn/Pellet Stove
Fig. 11
Fig. 12
venting
#3 Installing into an existing chimney
This method provides excellent venting for normal
operation. This method also provides natural draft in
the event of a power failure. If the chimney condition
is questionable you may want to install a liner as in
method #6. Check with your local regulations, some
municipalities require a complete liner.
#4 Installing into an existing fireplace
chimney
This method provides excellent venting for normal
operation. This method also provides natural draft in
the event of a power failure.
The damper area must be sealed with a steel plate.
Kaowool, mineral wool or an equivalent non-combus-
tible insulation is recommended to be installed on top
of the sealing plate to reduce the possibility of con-
densation. The connector pipe should extend through
the smoke chamber to the base or into the first flue
tile. A cap should be installed on the chimney to keep
out rain. If the chimney condition is questionable you
may want to install a liner all the way to the top as in
method #5. Check with your local regulations, some
municipalities require a complete liner.