       These units are pre-tested at the factory with exactly 

120 Volts A.C., 60 Hz. They are checked and adjusted  

for firebox tightness, gasket leakage, motor operation 

and ignitor operation.  The PC 45 is then factory set 

at a mid-point adjustment and in most cases will not 

need any adjustments.  

NOTE: The factory low draft 

setting may not be correct for the unit's permanent 

installation conditions.

       The  control  board  on  the  PC45  is  equipped  with 

a  low  draft  adjustment  port.  Located  on  the  control 

face  just  to  the  right  of  the  igniter  light. This  voltage 

adjustment is provided to allow the unit to be adjusted 

for the household voltage where the unit is going to be 

in permanent operation. NOTE: The line voltage varies 

from area to area and often home to home.

      The low draft voltage should be adjusted to achieve 

the most efficient burn on low burn or "maintenance". 

This voltage adjustment allows the installer to change 

the low voltage set point approximately 10 volts.  This 

adjustment should be done by the installer during set 

up because a draft meter reading is 

required 

to insure 

proper set up.

       If the unit is not  adjusted properly, it does not cause 

a safety concern. If the unit is adjusted too high, only 

effiency is lost. If the unit is adjusted too low, the low 

draft pressure switch will not allow the feeder motor or 

the igniter to operate

.

       

A  simple  draft  test  should  be  performed  after 

completing the flue pipe installation. To record the results 

for future reference:

Combustion Motor Speed Control
Low draft only set point.
The small straight screwdriver slot is plastic; therefore,  the unit 
can be adjusted while in operation.

Fig. 27

Fig. 28

draft Test Instructions

1. Attach  a  draft  meter  capable  of  reading  up  to  a 

minimum of 0.5 inches of water column (W.C.).

2.  Plug  the  unit's  power  cord  into  a  120VAC,  60  HZ 

grounded outlet.

3. Close the hopper lid, front view door, and the ash 

pan access door. Neither fuel or a fire are required for 

this test.

4. With the mode selector in the "OFF" position, turn the 

feed adjuster to "TEST".

5. Record the high draft_____in W.C. (Normal is 

-.35 to -.55) The control will be on the High Draft for a  

minute.

6. After 1 minute is up, the combustion motor will go 

down to low draft and the distribution blower will go on 

high. Allow approximately 15 seconds to pass for the 

combustion motor to slow before checking the low draft.

7. If the low draft is between -.25 and -.35, record the 

reading _____ in W.C.  If the reading is higher, slowly 

turn  the  set  screw  counter-clockwise  until  the  draft 

lowers. If the reading is lower, very slowly turn the set 

screw clockwise until the draft increases.

NOTE: In some cases, the draft may not go as low 

as -.25 to -.35 even with the set screw completely 

counter-clockwise. This is not a problem. vertical 

runs of venting may add natural draft.

If the draft reading does not drop at all when the test 

mode switches from high to low, be sure to check 

for restrictions in the appliance air intake. 

low  draft  voltage  Adjustment

draft  meter  bolt 

hole location

On a PC 45 the draft 

hole is under the left 

rear  corner  of  the 

firebox.

low  draft  voltage  Adjustment

Содержание PC 45

Страница 1: ...FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as m...

Страница 2: ......

Страница 3: ...ELACONSTRUC TION OU LE BUREAU DES POMPIERS AU SUJET DES RESTRICTIONS ET DES INSPECTIONS D INSTALLATION DANS VOTRE VOISINAGE EXEMPTION EPA PAR 40 CFR 60 534 DE M THODE 28a APPROUV POUR L USAGE DANS LES...

Страница 4: ...e ment during shipping To free the stove from the skid you must remove the hold down bolts in the rear of the pedestal base Removing or Installing rear panels To remove the rear cover panels loosen th...

Страница 5: ...efore use and at least annually by a qualified service person More frequent cleaning will be required It is imperative that control compartments burners and circulating air passageways of the stove be...

Страница 6: ...12 H A vent must not be installed within 3 feet 90 cm above a gas meter regulator assembly when measured from the horizontal center line of the regulator 1 I The clearance to service regulator vent o...

Страница 7: ...to burn corn or other grains be sure venting system is approved and warranted for corn burning The sections of pipe lock together to form an air tight seal however in some cases a perfect seal is not...

Страница 8: ...deration must be given to the total house demand House demand may consume the air needed for the stove It may be neces sary to add additional ventillation to the space in which the appliance is locate...

Страница 9: ...ral draft in the event of a power failure 2 Preferred method This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall The vertical...

Страница 10: ...venting for normal operation This method also provides natural draft in the event of a power failure The damper area must be sealed with a steel plate Kaowool mineral wool or an equivalent non combus...

Страница 11: ...sure to use approved pellet vent pipe fittings Seal pipe joints with silicone in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 6 Installi...

Страница 12: ...the ceiling vent follow PL vent manufacturers recommendations when using wall and ceiling pass through DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT...

Страница 13: ...low the grain cap to rest onto the burnpot sides Grain Cap Burn Pot Fig 18 Burn Pot with Smaller Holes The PC45 stove is built with a burn pot that has 125 1 8 combustion air holes This grate has no i...

Страница 14: ...board switches The pellet kit contains the instructions for the conversion a new burn pot end gate and a new combustion blower inlet ring This figure shows the corn burn pot as installed from the fac...

Страница 15: ...n the yellow range with a 3 setting being the maximum setting 1 the lowest setting This setting will vary depending on the quality of corn used When burning pellets the feed rate setting can be adjust...

Страница 16: ...he feed adjuster to TEST until the fuel is visible in the auger tube opening This also allows you to check the motors for operation NOTE The auger motor will not operate with the view door or ash door...

Страница 17: ...om Tempera ture Mode and Manual Room Temperature Mode is that the fire will not go out as the room temperature goes above the control board setting The unit can only go to low burn and will remain the...

Страница 18: ...ned Burning Corn 1 Turn the Feed Adjuster to the desired feed rate approximately 2 2 Turn the Mode Selector to OFF and then to the desired mode This will reset the control and start the combustion mot...

Страница 19: ...elow Indicates power to distribution blower 6 Blinks Indicates that the control has calculated poor or incomplete combustion occurring for more than 50 minutes See Troubleshooting section for more de...

Страница 20: ...rd the results for future reference Combustion Motor Speed Control Low draft only set point The small straight screwdriver slot is plastic therefore the unit can be adjusted while in operation Fig 27...

Страница 21: ...away from all combustible materials pending final disposal If ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders...

Страница 22: ...the fuel being used Fig 36 For further details see exploded view on page 22 Cleaning continued 5 Remove the ash pan 6 Remove the combustion blower cover by turning the blower cover latch vertical as...

Страница 23: ...n cool the parts can just be left exposed for several days and the slag buildup will crumble off of the parts 2 To accelerate this process the parts can be soaked in water for approximately 30 minutes...

Страница 24: ...ate too high B Draft too low caused by a gasket leak 2 Unit is in an ignition cycle LOW HEAT OUTPUT 1 Feed rate too low 2 Temperature setting too low Stove Temp Mode 3 Draft too low because of gasket...

Страница 25: ...moisture content takes energy to dry and tends to cool the appli ance thus robbing heat from your home Damp pellet fuel could turn back into sawdust which does not flow properly through the feed syst...

Страница 26: ...ove Weight 249 lbs Blower 135 cfm Feed Rate 0 to 5 0 lbs per hr Hopper Capacity 80 lbs Fuel Corn Wood Pellets Flue Size 3 inch Outside Air Size 2 3 8 I D Fuse Rating 6 amp 32 375 9 23 5 34 5 5 250 12...

Страница 27: ...e plating and therefore should never be used If the plating needs to be cleaned wait until the stove is completely cool then use a sponge soap and water to gently remove dirt and stains Before relight...

Страница 28: ...re than 25 feet from the unit or in another room are not recommended It is recommended that the room sensor be in stalled even if only installed on the rear of the unit as a return air sensor Room Sen...

Страница 29: ...S GROUND 18 3 RUBBER CORD N O WHITE BLUE GREEN WHITE GREEN RED ESP PROBE 6 AMP GLASS FUSE PART NO 3 89 02676D BLUE 120 VOLTS A C 60 HZ FEEDER AUGER MOTOR PUMP BLACK RED REMOTE SENSOR PORTS IGNITER ELE...

Страница 30: ...truction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlie...

Страница 31: ...t of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enamel...

Страница 32: ...let Part number list on following page 1 90 06800 1 black 1 90 06800 2 Charcoal 1 90 06800 3 goldenfire 1 90 06800 4 metallic blue 1 90 06800 5 honey glo 1 90 06800 10 mojave red 1 90 06800 12 Forest...

Страница 33: ...8055950 1 10 09685A Y 2 Feeder Assembly Pre 008055950 1 10 724129A 2 1 Air Intake Damper 1 10 06466W 2 2 Air Intake Weldment 1 10 06461 2 3 Feeder Weldment 1 10 724128 2 4 Slide Plate Assembly 1 10 08...

Страница 34: ...677122 Y 3 4 9MM Silicone Tube 5 FT 1 00 511427 Y 3 5 UL Feeder Auger Assembly 3 50 00665 Y 3 6 Bearing Flange w Hardware 1 00 04035 Y 3 7 UL Cast Cam Block 3 00 677154 Y 3 8 UL Motor Mount W Grommet...

Страница 35: ...olt on Hinge Weldment 2 00 06952B 17 Cast Door Frame 4 00 06800P 18 Glass Panel 3 40 950133125 Y 19 Door Handle Assembly Pre 1529 1 00 08704 Y Post 1529 1 00 453001 Y Wooden Handle w Hardware Load Doo...

Страница 36: ...135 Y Arrow Burn Pot Scraper Pkg of 10 2 00 773850 10 Fan Blade 5 Single Paddle Combustion Blower 3 20 40985 Y Fuse 6 Amp Pkg of 5 3 20 49447 5 Y Gasket 1 4 Rope Black W PSA Per Inch Glass 15 Ft 1 00...

Страница 37: ...It is not intended for continued operation Your appliance will recognize when power is restored What happens depends on ESP temperature and whether it is equipped with automatic ignition In Automatic...

Страница 38: ...38 pC 45 Corn pellet Stove Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 39: ......

Страница 40: ...Proudly Printed On 100 Recycled Paper...

Отзывы: