background image

Inspection Procedure 
CMC CLUTCH™ by Harken Industrial™

 

 

 

 

 

 

 
 
 

 

 
 

 

 

 

 
 
 
 
 
 
 
 
 
 

If the wear indicators have been worn away, the unit must be retired. 

 

2.

 

 Functional Checks 

 

2.1

 

  Sheave Movement 

Open the device and perform the following checks on the Sheave: 

 

Ensure that the Sheave is able to rotate anti-clockwise and emits an audible clicking sound. 

 

Check that the Sheave is not able to rotate clockwise. 

 

Check that the Sheave is firmly attached to the Sheave Swing Arm without excessive axial movement, 
i.e. >2mm. 

 

2.2

 

  Sheave Swing Arm Movement 

 

With the device open, start with the Control Handle in the Stop position. Press the Sheave into the pinch 
area and check that the Sheave is able to swing into the Chassis and make contact with the stainless 
steel Friction Shoe.   

 

Release the Sheave and move the Control Handle to the Stand By position while observing the position 
of the Sheave and Sheave Swing Arm. The Sheave and Sheave Swing Arm should move to the left, 
rotating anticlockwise until the rope-path laser etching becomes visible on the inner surface of the 
Chassis.   

 

With the Control Handle in the Stand By position, press on the Sheave and check that the Sheave is able 
to swing into the Chassis and make contact with the stainless steel Friction Shoe. 

 

Check that the Sheave Swing Arm is firmly attached to the Chassis and inspect the rivet on both sides for 
damages. 

Содержание CMC CLUTCH

Страница 1: ...l CLUTCH Periodic PPE Inspection Form CLUTCH Inspection Procedure this document A new unused CLUTCH for comparison 2m of rope within the acceptable parameters for the CLUTCH see inside of Moving Side Plate or CLUTCH User Manual Documentation of product history from the user Product History The user should provide information regarding the lifecycle of the device Of special importance are Date of p...

Страница 2: ...lly compare the device with a new device and check to make sure that there are no missing or modified parts Carefully inspect the entire device for signs of damage such as dents deep scratches cracks yielding or excessive wear Check for any sharp edges especially in the areas of the rope path Take extra care to inspect attachment points such as the Attachment Eye and the Becket for signs of damage...

Страница 3: ... Stop position Press the Sheave into the pinch area and check that the Sheave is able to swing into the Chassis and make contact with the stainless steel Friction Shoe Release the Sheave and move the Control Handle to the Stand By position while observing the position of the Sheave and Sheave Swing Arm The Sheave and Sheave Swing Arm should move to the left rotating anticlockwise until the rope pa...

Страница 4: ...while maintaining pressure on the Sheave with the left hand until the Anti panic position is reached Check that the Sheave releases and is once again able to be pressed into the Chassis Inspect the rivet in the center of the Control Handle for damage Ensure that the Control Handle is firmly attached to the Chassis and has minimal clearance with the Chassis 2 4 Side Plate Release Latch and Moving S...

Страница 5: ... exiting the device 2 Gradually apply a load to the device rope taut Control Handle in the Stand By position Gradually move the Control Handle to the Release Range position to allow rope through the device Check that it is possible to move rope through the device 3 While maintaining load on the device release the Control Handle and check that the device locks up and holds the rope 4 While maintain...

Страница 6: ...inspection points are marked as Fail then the device should be dispositioned as Fail Disposition States Pass Continue to use next required periodic check in 12 months Monitor Use with caution next required periodic check in 12 months document date on Periodic PPE Inspection Form Fail Do not use render device useless before disposal to prevent further use CMC Rescue Inc 6740 Cortona Drive Goleta CA...

Отзывы: