background image

PARTS AND ASSEMBLY IDENTIFICATION – MANUAL AND VARIABLE VALVE 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

18 

WARNING:

 Failure to position the parts in accordance with these diagrams or failure to use only parts 

specifically approved with this heater may result in property damage or personal injury. 

Manual Vent Free Burner Assembly 

Variable Vent Free Burner Assembly 

 

 

ITEM 

DESCRIPTION 

 

 

QTY 

ET(HC,CC)18(N,P)(1G,1E) 

ET(HC,CC)24(N,P)(1G,1E) 

ET(HC,CC)30(N,P)(1G,1E) 

A. 

GRATE SYSTEM 

 

 

VF18-GR 

 

 

VF24-GR 

 

 

VF24-GR 

B. 

LEFT EMBER BRACKET   

 

VF-BR-EL-18 

 

VF-BR-EL-24 

 

VF-BR-EL-24 

 

RIGHT EMBER BRACKET  

 

VF-BR-ER-18 

 

VF-BR-ER-24 

 

VF-BR-ER-24 

C. 

BRASS ELBOW FOR ORIFICE 

 

49-6-6Z2 

 

 

49-6-6Z2 

 

 

49-6-6Z2 

 

ORIFICE SPUD 

 

 

ZRPTT-60 

 

 

ZRPTT-60 

 

 

ZRPTT-60 

BACK BURNER 

 

 

VF-IB-BK-18  

 

VF-IB-BK-24  

 

VF-IB-BK-24 

E. 

ROTARY VALVE (NG,LP)   

 

MAXGV36-B1AO(N,L)TH   

MAXGV36-B1AO(N,L)TH   

MAXGV36-B1AO(N,L)TH 

F. 

CONTROL KNOB (1G) 

 

 

SPC-K 

 

 

SPC-K 

 

 

SPC-K 

G. 

MANUAL VALVE (1G) 

 

 

CVC-C 

 

 

CVC-C 

 

 

CVC-C 

H. 

REGULATOR (1G NG) 

 

 

REG 4 

 

 

REG 4 

 

 

REG 4 

 

REGULATOR (1G LP) 

 

 

REG 10 

 

 

REG 10 

 

 

REG 10 

I. 

SPARK IGNITOR (1G) 

 

 

SIT-PIEZO   

 

SIT-PIEZO   

 

SIT-PIEZO 

OXYGEN DEPLETION SYSTEM (NG)   

OP-8203-ODS-NG 

 

OP-8203-ODS-NG 

 

OP-8203-ODS-NG 

 

OXYGEN DEPLETION SYSTEM (LP) 

 

OP-8403-ODS-LP 

 

OP-8403-ODS-LP 

 

OP-8403-ODS-LP 

FLEW CONNECTOR 

 

 

FC-22 

 

 

FC-22 

 

 

FC-22 

L                   FRONT BURNER 

 

 

VF-IB-FR-18  

 

VF-IB-FR-24  

 

VF-IB-FR-24 

 

 

 

 

 

 

Содержание HARETHC24N2C

Страница 1: ...designed to supplement a current heating system It is not designed to be used as a primary heat source FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicini...

Страница 2: ...th the appliance It is recommended that adults be present when this gas appliance is operating It is recommended that this unit is not left burning when unattended or while anyone is sleeping 8 Childr...

Страница 3: ...BURNING APPLIANCES IN THE SPACE VENT FREE HEATER_________________BTU Hr GAS APPLIANCE 1 _________________BTU Hr GAS APPLIANCE 2 _________________BTU Hr Example VENT FREE HEATER 26 000 BTU Hr GAS APPLI...

Страница 4: ...d clockwise for min heat Input ratings are shown in BTU per hour and are for elevations up to 2 000 feet For elevations above 2 000 feet input ratings should be reduced 4 for each 1 000 feet above sea...

Страница 5: ...that heat warping or discoloration will never occur The possibility of heat damage exists whether burning wood or gas logs Refer to Fig 1 for the following dimensions A Minimum left and right clearan...

Страница 6: ...screen must be in place when the appliance is operating unless other provision for combustion air are provided the screen shall have an opening s for introduction of combustion air NOTE Before you pr...

Страница 7: ...a vented firebox if the damper is used the burner assembly should be located directly under the damper 5 Use the 3 8 flex connector provided in the accessory kit to connect the gas supply line to the...

Страница 8: ...n BTU Rating and Pressure Requirements pg 3 contact your dealer 4 Replace the test plug after measuring gas pressure Check for gas leaks IMPORTANT Do not use the appliance if any part has been submerg...

Страница 9: ...t side on the notch of the 5310 and the notch on the front right log Fig 1 2 Step 8 Install the 5314 by placing the flat side in the notches on the top of the back log and the front right log Fig 1 2...

Страница 10: ...ogs Fig 1 2 Step 5 Install the 5112 by placing the flat end on the notch of the 5113 and the notch on the front left log Fig 1 2 Step 6 Install the 5110 by placing the flat side of the log on the notc...

Страница 11: ...flat side of the log on the notch of the 5113 and the notch on the top of the back log Fig 1 2 Step 7 Install the 5407 by placing the flat side on the notches of the front and back logs Fig 1 2 Step...

Страница 12: ...be covered as possible Fig 3 4 DO NOT PRESS THE EMBER MATERIAL INTO THE BURNER PORTS 4 You may place some ember material on the tube that connects the front and back burner Do not press the ember mat...

Страница 13: ...er on the floor of the fireplace DO NOT POUR ANY VOLCANIC CINDER ON THE BURNERS OR AROUND THE PILOT 2 You may use the Volcanic Cinder to cover up the Lighting Tags that are attached to the set DO NOT...

Страница 14: ...mell gas go to the next step 5 Turn the Control Knob counterclockwise to the PILOT position 6 Push in control knob and hold it in 7 Light the pilot mounted in the front of the back burner by pushing t...

Страница 15: ...ain the IGN position push the knob in as far as it will go This action releases gas flow to the pilot 7 While holding in the Pilot Ignitor Knob turn it counterclockwise to activate the spark ignitor o...

Страница 16: ...TOP Follow B in the safety information above on this label If you do not smell gas go to the next step 5 Depress the control knob and turn counterclockwise to the PILOT position LIGHTING INSTRUCTIONS...

Страница 17: ...erns Do not allow fans to blow directly into the fireplace Ceiling fans may create drafts that alter burner flame patterns Sooting and improper burning will occur Installation and repair should be don...

Страница 18: ...BR ER 18 VF BR ER 24 VF BR ER 24 C BRASS ELBOW FOR ORIFICE 2 49 6 6Z2 49 6 6Z2 49 6 6Z2 ORIFICE SPUD 2 ZRPTT 60 ZRPTT 60 ZRPTT 60 D BACK BURNER 1 VF IB BK 18 VF IB BK 24 VF IB BK 24 E ROTARY VALVE NG...

Страница 19: ...EMBER BRACKET 1 VF BR ER 18 VF BR ER 24 VF BR ER 24 C BRASS ELBOW FOR ORIFICE 2 49 6 6Z2 49 6 6Z2 49 6 6Z2 ORIFICE SPUD 2 ZRPTT 60 ZRPTT 60 ZRPTT 60 D BACK BURNER 1 VF IB BK 18 VF IB BK 24 VF IB BK 24...

Страница 20: ...alve not fully open 4 Thermocouple connection loose at valve 5 Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This problem could be caused by one...

Страница 21: ...paint fumes cleaning agents pet hair or other particles are cycling thru the fireplace when it is operating 2 Gas leak 1 Logs are not positioned properly and are obstructing the flame 2 Main burner h...

Страница 22: ...ranty applicable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above li...