24
FIG. 20 REMOVING LOAD SENSOR BOLTS
AND FEET
Step 12. Place the new load sensor so that the
through bolt holes are aligned with the
threaded mounting holes and in the same
direction as the old load sensor. DO NOT
CUT OR REUSE THE OLD CABLE ON
THE NEW LOAD SENSOR.
Step 13. Screw in the two (2) load sensor bolts that
fasten the load sensor to the mount.
Tighten the bolts finger tight.
Step 14. Use a Torque Wrench and tighten the bolts
to the torque rating in Table 4. It is a good
idea to switch back and forth between each
bolt until the torque value has been
reached.
Table 4: Torque Specifications for Load Sensor
Bolts
BOLT
Grade
Torque
.500 - 20 UNC
(M12 8.8)
5
65 Ft/Lbs (90 Nm)