Hardy Floor Scales
8
the direction indicated in Figure 3. Also See
Access Ramp Installation Section.
Load and unload
heavy equipment
in this direction only!
FIG. 3 DIRECTION WHEN DRIVING HEAVY
EQUIPMENT ON AND OFF THE SCALE
FLOOR SCALE
INSTALLATION
Step 1.
Place the platform scale on the operating
location. Make sure that the platform
height is within 3 to 3.275" as measured
from the top of the cover plate to the top of
the floor surface. (See Fig. 4)
NOTE:
With the scale in place, the clearance around the edge
of the platform and pit coping should be 1/4” to 3/8”.
3.275” (83.1mm)
FIG. 4 MAXIMUM HEIGHT