Operating state
Your cPP2 charging pole is designed for maximum operational safety and the most
reliable charging possible. Any malfunction of the cPP2 is detected by internal test
routines and the charging pole is switched off immediately.
If a malfunction should occur in practice, it is indicated via the status LED in the head
area of the cPP2 and via the LEDs in the RFID module. The following chapter describes
how to recognise operating and error states and which measures you have to take to
remedy the malfunction.
Status-LED
The LED status indicators at the top of the charging pole show the current operating
status. For display purposes, the LEDs can be...
•
...light up (permanently on)
•
...flashing (1Hz)
•
...not light up (permanently off)
In normal operation, the following colours and states are displayed:
Status-LED
Description
Green
Charging pole/charging point is ready for operation. The vehicle
can be connected.
Yellow
Vehicle is connected and ready to charge (or fully charged)
Blue
The vehicle is currently being charged.
Red
Error occurred during charging (notify technician)
Purple flashing
OCPP authentication phase (only for backend connection)
Green flashing
Update process (do NOT switch off the charging station)
Red flashing
Internal DC fault current detection has triggered. Disconnect
vehicle and try again.
Off
No power supply (check external fuses) / Check internal control
fuse (notify technician)
Installation and operating manual
cPP2
charging pole
Version: 1.0.2
29