![Hardi SARITOR 4000 Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/hardi/saritor-4000/saritor-4000_operators-manual_597264061.webp)
5 - Operation
59
B: External cleaning
This procedure is used to rinse the outside of the sprayer in the field as required.
±
WARNING! Never clean the sprayer if there are risks of contamination of surface or underground water! Choose a
different spot for cleaning every time to avoid spot contamination to build up.
Use the External Cleaning Device to wash everything on the outside
of the sprayer. This prevents contamination of the storage area and
helps the sprayer last longer. When the External Cleaning Device is
going to be used, open the cover for the fluid system on sprayer’s left
side.
The cleaning gun is located on the inner side of the cover.
1.
Un-roll the hose from the reel (B) and take the handle (C).
2.
Engage clean water pump (A) by pressing the ON/OFF switch at
the end of the pump.
3.
After cleaning, turn off the clean water pump by pressing the
ON/OFF switch.
4.
Roll the hose onto the reel again and close cover.
C. Flushing spraying circuit without diluting main tank contents
This procedure is used to flush the pump, operating unit, spray lines, etc. in case of interruption in spraying before main tank
is empty (e.g. beginning rain, etc.).
Flushing of the liquid system
1.
Turn off the pump.
2.
Turn on the Rinse Tank valve.
3.
Turn on the Boom nozzles.
4.
Turn off the agitation valve (no agitation).
5.
Press the CycloneFilter Boost Valve to down position to avoid dilution of main tank contents.
6.
Engage the pump and spray water from rinse tank in the field until all nozzle tubes/nozzles are flushed with clean
water.
7.
Disengage the pump.
±
WARNING! Don’t turn Boom Spray nozzles off until the pump has fully stopped, otherwise diluting of main tank
contents will occur.
ATTENTION! It is advisable to increase the forward speed (double if possible) and reduce the pressure to 20 psi (1.5
bar) when spraying diluted remaining liquid in the field just sprayed.
ATTENTION! If a cleaning procedure is given on the chemical label, follow it closely.
ATTENTION! If the sprayer is cleaned with a high pressure cleaner, lubrication of the entire machine is recommended.
B
C
A
Содержание SARITOR 4000
Страница 1: ...The Sprayer Operator s Manual SARITOR 4000 5000 Instruction book 67023003 Version 1 10 US 10 2016 ...
Страница 2: ......
Страница 4: ......
Страница 10: ...1 Welcome 8 ...
Страница 64: ...5 Operation 62 ...
Страница 84: ...7 Fault finding 82 Electrical incidents Main circuit fuses and relays U100163B ...
Страница 92: ...Index 90 ...
Страница 93: ......