5 - Operation
51
Liquid system
Filling/washing location requirements
When filling the sprayer with chemicals and water, it is important to avoid spot contamination by spray chemicals in order
to protect the subsoil water resources.
A.
If the sprayer is always filled at the same place, a special filling/washing location should be established. This should
have a hard, liquid-impenetrable surface (e.g. concrete) and edges securing against run-off to the surrounding areas.
The place should be drained to an adequate receptacle (e.g. slurry tank or similar).
Any spillage or washings should be retained and diluted in order to be distributed on a larger area to ensure minimal
environmental impact and avoid build-up of larger chemical concentrations at one spot.
B.
Alternatively the sprayer can be filled in the field where the spraying is to take place. If so, choose a different location
for each refilling.
If no other requirements of distances exist, the filling should not take place closer than:
1) 300 yards (meters) from any water supplies for drinking purposes,
2) 25 yards (meters) from treatment sumps and sewer drainage systems, and
3) 50 yards (meters) from surface water (watercourses, lakes and coastal waters) and from nature reserves.
ATTENTION! Legislation and requirements vary from country to country. Always follow local legislation in force at any
time.
÷
Note: It is the responsibility of the sprayer owner/operator to comply with all relevant legislation. HARDI® cannot
undertake any responsibilities for incorrect operation and use.
Filling of water
Tank should normally be filled 1/3 with water before adding chemicals. Always
follow instructions given on the chemical container!
±
WARNING! If the sprayer is put aside with liquid in the main tank, all
MANIFOLD valves must be closed.
Main Tank Filling
The Main Tank can be filled using the Filtered Fast Fill System.
1/3
Содержание SARITOR 4000
Страница 1: ...The Sprayer Operator s Manual SARITOR 4000 5000 Instruction book 67023003 Version 1 10 US 10 2016 ...
Страница 2: ......
Страница 4: ......
Страница 10: ...1 Welcome 8 ...
Страница 64: ...5 Operation 62 ...
Страница 84: ...7 Fault finding 82 Electrical incidents Main circuit fuses and relays U100163B ...
Страница 92: ...Index 90 ...
Страница 93: ......