3 - Description
18
Filters
A EasyClean suction filter is fitted in the working zone.
A Cyclone pressure filter is fitted to the sprayers right side just in front of the ChemLocker (optional equipment). It has a built-
in self-cleaning function.
In-line pressure filters can be fitted at each boom section as an option.
Nozzle filters are fitted at each nozzle.
All filters should always be in use and their function checked regularly. Pay attention to the correct combination of filter and
mesh size (see “Spray Technique” book).
EasyClean Filter
To ensure proper function of filter and its built-in valve the filter must be
opened at least once every month. A label on the lid also designates this.
•
To open filter then turn it counterclockwise and pull it up, like
shown on picture.
•
Pull out the two locks (A) to remove filter element from the lid.
Besides the spray pressure gauge on the platform an EasyClean
clogging indicator is located:
Clogging indicator colour
Filter status
Green indicator.
No cleaning necessary.
Yellow indicator.
It is possible to finish an ongoing spraying job and
then clean filter afterwards.
Red indicator.
Clean the EasyClean Filter immediately, as the filter is
clogged.
Содержание NAVIGATOR 4000
Страница 1: ...NAVIGATOR 3000 4000 5000 6000 Instruction book 67028104 102 Version1 02 GB 05 2016 www hardi com au...
Страница 12: ...2 Safety notes 10...
Страница 36: ...3 Description 34...
Страница 78: ...5 Operation 76...
Страница 80: ...6 Maintenance 78 PTO Lubrication Oiling Plan PTO shaft type 100 series C 50...
Страница 95: ...6 Maintenance 93...
Страница 96: ...6 Maintenance 94...
Страница 102: ...7 Fault finding 100...
Страница 114: ...Index 112...
Страница 116: ...HARDI Australia P L 534 538 Cross Keys Rd Cavan SA 5094 AUSTRALIA...